Basic walker-assisted gait characteristics derived from forces and moments exerted on the walker's handles: results on normal subjects.

This paper describes a method that passively assesses basic walker-assisted gait characteristics using only force-moment measurements from the walker's handles. The passively derived gait characteristics of 22 subjects were validated against motion capture gait analysis. The force-moment based heel initial contact detection algorithm have produced a high level of concordance with heel initial contacts detected by a human inspecting the heel marker data sets of the Vicon video capture system. The algorithm has demonstrated 97% sensitivity and 98% specificity with a narrow 95% confidence interval of +/-1% during all experiments, which included five navigational scenarios. Temporal error in detecting the instances of heel initial contacts were within 5.27+/-3.66% of the overall stride time obtained from Vicon when the subjects walked in a straight line, whereas the toe-off instance estimates were within 5.18+/-2.75% of the gait cycle. The errors in determining the duration of stride time, single support, and double support were within 5.86+/-2.49%, 5.24+/-2.29%, and 4.34+/-2.13% of the gait cycle respectively. The stride time estimated, using the method presented here, correlated well with stride time computations based on visual inspection of Vicon's data, Pearson correlation coefficient r=0.86 for straight line segments. However, absolute errors were too high to estimate the single and double support phases with acceptable accuracy. The potential application of the instrumented walker and the method presented here is longitudinal basic gait assessment that can be performed outside of the conventional gait labs.

[1]  Sheldon R Simon,et al.  Quantification of human motion: gait analysis-benefits and limitations to its application to clinical problems. , 2004, Journal of biomechanics.

[2]  John G. Proakis,et al.  Digital signal processing (3rd ed.): principles, algorithms, and applications , 1996 .

[3]  M.R. Popovic,et al.  A reliable gyroscope-based gait-phase detection sensor embedded in a shoe insole , 2004, IEEE Sensors Journal.

[4]  Pradip Sheth,et al.  User intent in a shared control framework for pedestrian mobility aids , 2003, Proceedings 2003 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2003) (Cat. No.03CH37453).

[5]  K. Aminian,et al.  Temporal feature estimation during walking using miniature accelerometers: an analysis of gait improvement after hip arthroplasty , 1999, Medical & Biological Engineering & Computing.

[6]  Sean Graves,et al.  An assistive robotic agent for pedestrian mobility , 2001, AGENTS '01.

[7]  G. Lyons,et al.  The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking. , 2003, Medical engineering & physics.

[8]  Sean Graves,et al.  Effective Shared Control in Cooperative Mobility Aids , 2001, FLAIRS.

[9]  M. Alwan,et al.  Passive derivation of basic walker-assisted gait characteristics from measured forces and moments , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  G.F. Harris,et al.  Walker-assisted gait in rehabilitation: a study of biomechanics and instrumentation , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[11]  T. Karčnik,et al.  Using motion analysis data for foot-floor contact detection , 2003, Medical and Biological Engineering and Computing.

[12]  M. Wong,et al.  Temporal stride and force analysis of cane-assisted gait in people with hemiplegic stroke. , 2001, Archives of physical medicine and rehabilitation.

[13]  M.M. Skelly,et al.  Real-time gait event detection for paraplegic FES walking , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[14]  M. Feinleib National Center for Health Statistics (NCHS) , 2005 .

[15]  G. W. Snedecor Statistical Methods , 1964 .

[16]  M.R. Popovic,et al.  A reliable gait phase detection system , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[17]  M. Boninger,et al.  The science behind mobility devices for individuals with multiple sclerosis. , 2002, Medical engineering & physics.

[18]  A Fast,et al.  The instrumented walker: usage patterns and forces. , 1995, Archives of physical medicine and rehabilitation.

[19]  John G. Proakis,et al.  Digital Signal Processing: Principles, Algorithms, and Applications , 1992 .