Quality Assurance of Clinical MRI Scanners Using ACR MRI Phantom: Preliminary Results

Clinical magnetic resonance imaging (MRI) scanners play an important role in the diagnosis of diseases and management of patient treatment. Quality assurance (QA) of the clinical MRI scanners is mandatory to obtain optimal images in a modern hospital. In this report, the phantom test for the American College of Radiology (ACR) MRI accreditation is used as the essential part of the MRI QA protocols. Seven important assessments of MR image quality are included as follows: geometric accuracy, high-contrast resolution, slice thickness accuracy, slice position accuracy, image intensity uniformity, percent signal ghosting, and low-contrast object detectability. In addition, signal-to-noise ratio and central frequency are monitored as well. The MRI QA procedures were applied to four clinical MRI scanners in our institute twice within 3 months. According to the QA results, the service engineers were more efficient in solving scanners problems when the ACR phantom test was run.

[1]  Th. Krahe,et al.  Qualitätskontrolle der quantitativen MR-Tomographie : in-vitro- und in-vivo-Überprüfung von Relaxationszeitmessungen , 1990 .

[2]  F Podo Controlli di qualità nella risonanza magnetica ad uso clinico , 1994 .

[3]  T W Redpath,et al.  Estimating achievable signal-to-noise ratios of MRI transmit-receive coils from radiofrequency power measurements: applications in quality control. , 2000, Physics in medicine and biology.

[4]  F L Bookstein,et al.  Automated analysis of multiple performance characteristics in magnetic resonance imaging systems. , 1986, Medical physics.

[5]  D Gibon,et al.  Automatic quality assessment protocol for MRI equipment. , 1999, Medical physics.

[6]  T Krahe,et al.  [Qualitative control over quantitative MR tomography: in vitro and in vivo checks on relaxation time measurements]. , 1990, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[7]  P. Ring,et al.  Evaluation of Relaxation Time Measurements by Magnetic Resonance Imaging , 1987, Acta radiologica.

[8]  L Mascaro,et al.  [Results of the quality control of magnetic resonance images]. , 1992, La Radiologia medica.

[9]  Aaron J. Miller,et al.  The use of power images to perform quantitative analysis on low SNR MR images. , 1993, Magnetic resonance imaging.

[10]  S Strocchi,et al.  [Definition criteria for a magnetic resonance quality assurance program: multicenter study]. , 1999, La Radiologia medica.

[11]  P L Carson,et al.  MRI scanner variability studies using a semi-automated analysis system. , 1994, Magnetic resonance imaging.

[12]  R M Harrison,et al.  Quality assurance for MRI: practical experience. , 2000, The British journal of radiology.

[13]  F Podo [Quality control in magnetic resonance for clinical use]. , 1994, Annali dell'Istituto superiore di sanita.