Respiratory comfort and breathing pattern during volume proportional assist ventilation and pressure support ventilation: A study on volunteers with artificially reduced compliance

Objective To assess respiratory comfort and associated breathing pattern during volume assist (VA) as a component of proportional assist ventilation and during pressure support ventilation (PSV). Design Prospective, double-blind, interventional study. Setting Laboratory. Subjects A total of 15 healthy volunteers (11 females, 4 males) aged 21–31 yrs. Interventions Decreased respiratory system compliance was simulated by banding of the thorax and abdomen. Volunteers breathed via a mouthpiece with VA and PSV each applied at two levels (VA, 8 cm H2O/L and 12 cm H2O/L; PSV, 10 cm H2O and 15 cm H2O) using a positive end-expiratory pressure of 5 cm H2O throughout. The study was subdivided into two parts. In Part 1, volunteers breathed three times with each of the four settings for 2 mins in random order. In Part 2, the first breath effects of multiple, randomly applied mode, and level shifts were studied. Measurements and Main Results In Part 1, the volunteers were asked to estimate respiratory comfort in comparison with normal breathing using a visual analog scale. In Part 2, they were asked to estimate the change of respiratory comfort as increased, decreased, or unchanged immediately after a mode shift. Concomitantly, the respiratory pattern (change) was characterized with continuously measured tidal volume, respiratory rate, pressure, and gas flow. Respiratory comfort during VA was higher than during PSV. The higher support level was less important during VA but had a major negative influence on comfort during PSV. Both modes differed with respect to the associated breathing pattern. Variability of breathing was higher during VA than during PSV (Part 1). Changes in respiratory variables were associated with changes in respiratory comfort (Part 2). Conclusions For volunteers breathing with artificially reduced respiratory system compliance, respiratory comfort is higher with VA than with PSV. This is probably caused by a better adaptation of the ventilatory support to the volunteer’s need with VA.

[1]  A. Wilson,et al.  Comparison of breathing comfort during weaning with two ventilatory modes. , 1994, American journal of respiratory and critical care medicine.

[2]  J. Leiter,et al.  Tidal volume perception in normal subjects: the effect of altered arterial PCO2. , 1994, Respiration physiology.

[3]  M. Younes,et al.  Effect of inspiratory flow rate on respiratory output in normal subjects. , 1992, The American review of respiratory disease.

[4]  M. Younes,et al.  An apparatus for altering the mechanical load of the respiratory system. , 1987, Journal of applied physiology.

[5]  D Stagg,et al.  Interrelationships of the volume and time components of individual breaths in resting man. , 1975, The Journal of physiology.

[6]  N. Anthonisen,et al.  Effects of breathing route, temperature and volume of inspired gas, and airway anesthesia on the response of respiratory output to varying inspiratory flow. , 1996, American journal of respiratory and critical care medicine.

[7]  M J Jaeger Effect of the cheeks and the compliance of alveolar gas on the measurement of respiratory variables. , 1982, Respiration physiology.

[8]  Josef Guttmann,et al.  Continuous Calculation of Intratracheal Pressure in Tracheally Intubated Patients , 1993, Anesthesiology.

[9]  N. MacIntyre,et al.  Respiratory function during pressure support ventilation. , 1986, Chest.

[10]  J. Milic-Emili,et al.  Continuous positive airway pressure reduces work of breathing and dyspnea during weaning from mechanical ventilation in severe chronic obstructive pulmonary disease. , 1990, The American review of respiratory disease.

[11]  M. Younes Proportional assist ventilation, a new approach to ventilatory support. Theory. , 1992, The American review of respiratory disease.

[12]  J. Leiter,et al.  Effect of inspiratory flow rate on respiratory sensation and pattern of breathing. , 1995, American journal of respiratory and critical care medicine.

[13]  M. Younes,et al.  External mechanical loading in conscious humans: role of upper airway mechanoreceptors. , 1988, Journal of applied physiology.

[14]  E. Kinney Primer of Biostatistics , 1987 .