Elastic modulus imaging: some exact solutions of the compressible elastography inverse problem

We consider several inverse problems motivated by elastography. Given the (possibly transient) displacement field measured everywhere in an isotropic, compressible, linear elastic solid, and given density rho, determine the Lamé parameters lambda and mu. We consider several special cases of this problem: (a) for mu known a priori, lambda is determined by a single deformation field up to a constant. (b) Conversely, for lambda known a priori, mu is determined by a single deformation field up to a constant. This includes as a special case that for which the term [see text]. (c) Finally, if neither lambda nor mu is known a priori, but Poisson's ratio nu is known, then mu and lambda are determined by a single deformation field up to a constant. This includes as a special case plane stress deformations of an incompressible material. Exact analytical solutions valid for 2D, 3D and transient deformations are given for all cases in terms of quadratures. These are used to show that the inverse problem for mu based on the compressible elasticity equations is unstable in the limit lambda --> infinity. Finally, we use the exact solutions as a basis to compute non-trivial modulus distributions in a simulated example.

[1]  K D Paulsen,et al.  Magnetic resonance elastography using 3D gradient echo measurements of steady-state motion. , 2001, Medical physics.

[2]  Abbas Samani,et al.  A method to measure the hyperelastic parameters of ex vivo breast tissue samples. , 2004, Physics in medicine and biology.

[3]  F. Dunn,et al.  Comprehensive compilation of empirical ultrasonic properties of mammalian tissues. , 1978, The Journal of the Acoustical Society of America.

[4]  Jeffrey C Bamber,et al.  Evaluation of the adjoint equation based algorithm for elasticity imaging , 2004, Physics in medicine and biology.

[5]  J. F. Greenleaf,et al.  Magnetic resonance elastography: Non-invasive mapping of tissue elasticity , 2001, Medical Image Anal..

[6]  C. Sumi,et al.  Estimation of shear modulus distribution in soft tissue from strain distribution , 1995, IEEE Transactions on Biomedical Engineering.

[7]  K D Paulsen,et al.  An overlapping subzone technique for MR‐based elastic property reconstruction , 1999, Magnetic resonance in medicine.

[8]  Paul E. Barbone,et al.  Elastic modulus imaging: On the uniqueness and nonuniqueness of the elastography inverse problem in , 2004 .

[9]  Mathias Fink,et al.  Imaging of complex media with acoustic and seismic waves , 2002 .

[10]  M. Doyley,et al.  Evaluation of an iterative reconstruction method for quantitative elastography , 2000 .

[11]  Joyce R. McLaughlin,et al.  Unique identifiability of elastic parameters from time-dependent interior displacement measurement , 2004 .

[12]  Assad A. Oberai,et al.  INVERSE PROBLEMS PII: S0266-5611(03)54272-1 Solution of inverse problems in elasticity imaging using the adjoint method , 2003 .

[13]  Andrew M. Stuart,et al.  A First Course in Continuum Mechanics: Bibliography , 2008 .

[14]  Abbas Samani,et al.  Measuring the elastic modulus of ex vivo small tissue samples. , 2003, Physics in medicine and biology.

[15]  R L Ehman,et al.  Complex‐valued stiffness reconstruction for magnetic resonance elastography by algebraic inversion of the differential equation , 2001, Magnetic resonance in medicine.

[16]  T. Oliphant,et al.  Estimation of Complex-Valued Stiffness Using Acoustic Waves Measured with Magnetic Resonance , 2002 .

[17]  S. Emelianov,et al.  Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics. , 1998, Ultrasound in medicine & biology.