Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation.

PURPOSE/OBJECTIVE This study evaluates the dosimetric benefits and feasibility of a deep inspiration breath-hold (DIBH) technique in the treatment of lung tumors. The technique has two distinct features--deep inspiration, which reduces lung density, and breath-hold, which immobilizes lung tumors, thereby allowing for reduced margins. Both of these properties can potentially reduce the amount of normal lung tissue in the high-dose region, thus reducing morbidity and improving the possibility of dose escalation. METHODS AND MATERIALS Five patients treated for non-small cell lung carcinoma (Stage IIA-IIIB) received computed tomography (CT) scans under 4 respiration conditions: free-breathing, DIBH, shallow inspiration breath-hold, and shallow expiration breath-hold. The free-breathing and DIBH scans were used to generate 3-dimensional conformal treatment plans for comparison, while the shallow inspiration and expiration scans determined the extent of tumor motion under free-breathing conditions. To acquire the breath-hold scans, the patients are brought to reproducible respiration levels using spirometry, and for DIBH, modified slow vital capacity maneuvers. Planning target volumes (PTVs) for free-breathing plans included a margin for setup error (0.75 cm) plus a margin equal to the extent of tumor motion due to respiration (1-2 cm). Planning target volumes for DIBH plans included the same margin for setup error, with a reduced margin for residual uncertainty in tumor position (0.2-0.5 cm) as determined from repeat fluoroscopic movies. To simulate the effects of respiration-gated treatments and estimate the role of target immobilization alone (i.e., without the benefit of reduced lung density), a third plan is generated from the free-breathing scan using a PTV with the same margins as for DIBH plans. RESULTS The treatment plan comparison suggests that, on average, the DIBH technique can reduce the volume of lung receiving more than 25 Gy by 30% compared to free-breathing plans, while respiration gating can reduce the volume by 18%. The DIBH maneuver was found to be highly reproducible, with intra breath-hold reproducibility of 1.0 (+/- 0.9) mm and inter breath-hold reproducibility of 2.5 (+/- 1.6) mm, as determined from diaphragm position. Patients were able to perform 10-13 breath-holds in one session, with a comfortable breath-hold duration of 12-16 s. CONCLUSION Patients tolerate DIBH maneuvers well and can perform them in a highly reproducible fashion. Compared to conventional free-breathing treatment, the DIBH technique benefits from reduced margins, as a result of the suppressed target motion, as well as a decreased lung density; both contribute to moving normal lung tissue out of the high-dose region. Because less normal lung tissue is irradiated to high dose, the possibility for dose escalation is significantly improved.

[1]  Buist As Standardization of spirometry. , 1987 .

[2]  C. Burman,et al.  Three-dimensional conformal radiation therapy may improve the therapeutic ratio of high dose radiation therapy for lung cancer. , 1993, International journal of radiation oncology, biology, physics.

[3]  P. J. White,et al.  Comparison of dose homogeneity effects due to electron equilibrium loss in lung for 6 MV and 18 MV photons. , 1996, International journal of radiation oncology, biology, physics.

[4]  L. Chin,et al.  The influence of air cavities on interface doses for photon beams. , 1993, International journal of radiation oncology, biology, physics.

[5]  K. Ekstrand,et al.  Pitfalls in the use of high energy X rays to treat tumors in the lung. , 1990, International journal of radiation oncology, biology, physics.

[6]  J. Battista,et al.  Accuracy of lung dose calculations for large-field irradiation with 6-MV x rays. , 1986, Medical Physics (Lancaster).

[7]  H. Kubo,et al.  Respiration gated radiotherapy treatment: a technical study. , 1996, Physics in medicine and biology.

[8]  J. Lyman Complication Probability as Assessed from Dose-Volume Histograms , 1985 .

[9]  W. Döhring,et al.  A simple device for breath-level monitoring during CT. , 1985, Radiology.

[10]  W A Kalender,et al.  Measurement of pulmonary parenchymal attenuation: use of spirometric gating with quantitative CT. , 1990, Radiology.

[11]  W. Stanford,et al.  Analysis of movement of intrathoracic neoplasms using ultrafast computerized tomography. , 1990, International journal of radiation oncology, biology, physics.

[12]  K. Ohara,et al.  Irradiation synchronized with respiration gate. , 1989, International journal of radiation oncology, biology, physics.

[13]  R Mohan,et al.  A comprehensive three-dimensional radiation treatment planning system. , 1988, International journal of radiation oncology, biology, physics.

[14]  Andrzej Niemierko,et al.  Modelling tumor control probability , 1992 .

[15]  M. Goitein,et al.  Tolerance of normal tissue to therapeutic irradiation. , 1991, International journal of radiation oncology, biology, physics.

[16]  R. Mohan,et al.  Histogram reduction method for calculating complication probabilities for three-dimensional treatment planning evaluations. , 1991, International journal of radiation oncology, biology, physics.