Quantification of Mn in glass matrices using laser induced breakdown spectroscopy (LIBS) combined with chemometric approaches

A Q-switched solid state Nd:YAG laser operating at a third harmonic (355 nm) wavelength and an echelle spectrograph coupled with an ICCD system were used to study the plasma on a glass target. The present work is mainly focused on the investigation of multivariate calibration methods like principal component regression (PCR) and partial least squares regression (PLSR) for the analysis of Mn in complex matrices like glass. The glass studied has Mn as an analyte of interest whose doping concentration in the matrix varies from 0.77% to 11.61%. The performance of univariate and multivariate methods has been presented in this paper through their figures of merit. Improved prediction accuracy, limit of detection (LOD) and regression coefficients (R2) have been reported when the data were analyzed using PCR and PLSR. The calibration curves of six emission lines of Mn have been analyzed using a univariate method that resulted in R2 values varying from 0.85 to 0.98. This method resulted in a correlation uncertainty of 10% and a LOD of 0.20 wt%. R2 values of 0.98 to 0.99 have been obtained for the multivariate calibration curves of Mn analyzed in three selected regions of the LIBS spectrum. The optimum LOD and root mean square error of prediction (RMSEP) using PCR and PLSR were found to be 0.02 wt% and 0.54 wt%, respectively. The significant improvement in the analytical performances of multivariate calibration methods for the investigation of LIBS data is evident from the aforementioned results. Finally, the results of PCR and PLSR were confirmed by PCA classification.

[1]  Leon J. Radziemski,et al.  A brief history of laser-induced breakdown spectroscopy: From the concept of atoms to LIBS 2012 , 2013 .

[2]  K. Niemax,et al.  Laser induced breakdown spectrometry with an échelle spectrometer and intensified charge coupled device detection , 1998 .

[3]  N. B. Zorov,et al.  Comparison of single- and multivariate calibration for determination of Si, Mn, Cr and Ni in high-alloyed stainless steels by laser-induced breakdown spectrometry , 2014 .

[4]  Demetrios Anglos,et al.  Laser-induced breakdown spectroscopy (LIBS) in archaeological science—applications and prospects , 2007, Analytical and bioanalytical chemistry.

[5]  Paul Geladi,et al.  Principal Component Analysis , 1987, Comprehensive Chemometrics.

[6]  Nicoló Omenetto,et al.  Laser-Induced Breakdown Spectroscopy (LIBS), Part II: Review of Instrumental and Methodological Approaches to Material Analysis and Applications to Different Fields , 2012, Applied spectroscopy.

[7]  Jagdish P. Singh,et al.  Multivariate calibration of spectra obtained by Laser Induced Breakdown Spectroscopy of plutonium oxide surrogate residues , 2009 .

[8]  R. Minck,et al.  Spectrochemical analysis using a pulsed laser source , 1964 .

[9]  Yixiang Duan,et al.  Progress of Chemometrics in Laser-induced Breakdown Spectroscopy Analysis , 2015 .

[10]  H. Abdi,et al.  Principal component analysis , 2010 .

[11]  R. Noll,et al.  Laser-induced breakdown spectroscopy expands into industrial applications , 2014 .

[12]  S. Michael Angel,et al.  Enhancement of Aluminum, Titanium, and Iron in Glass Using Pre-Ablation Spark Dual-Pulse LIBS , 2000 .

[13]  Walid Tawfik Y. Mohamed Improved LIBS limit of detection of Be, Mg, Si, Mn, Fe and Cu in aluminum alloy samples using a portable Echelle spectrometer with ICCD camera , 2008 .

[14]  B. M. Suri,et al.  Optimized LIBS setup with echelle spectrograph-ICCD system for multi-elemental analysis , 2010 .

[15]  Nicolas André,et al.  Exploring laser-induced breakdown spectroscopy for nuclear materials analysis and in-situ applications , 2012 .

[16]  J. Yeon,et al.  Quantitative determination of uranium and europium in glass matrix by laser-induced breakdown spectroscopy , 2011 .

[17]  Suresh D. Kulkarni,et al.  Analytical predictive capabilities of Laser Induced Breakdown Spectroscopy (LIBS) with Principal Component Analysis (PCA) for plastic classification , 2013 .

[18]  J. D. Winefordner,et al.  Laser induced breakdown spectroscopy as a tool for discrimination of glass for forensic applications , 2008, Analytical and bioanalytical chemistry.

[19]  Chemical Analysis of High-Level Radioactive Waste Glass by ICP-AES , 1998 .

[20]  Jez Willian Batista Braga,et al.  Comparison of univariate and multivariate calibration for the determination of micronutrients in pellets of plant materials by laser induced breakdown spectrometry , 2010 .

[21]  S. S. Harilal,et al.  The role of laser wavelength on plasma generation and expansion of ablation plumes in air , 2013 .

[22]  Biomedical and environmental applicationsof laser-induced breakdown spectroscopy , 2014 .

[23]  Mohamad Sabsabi,et al.  Multi-elemental analysis of solidified mineral melt samples by Laser-Induced Breakdown Spectroscopy coupled with a linear multivariate calibration , 2007 .

[24]  Steven J. Spencer,et al.  Comparison of principal components regression, partial least squares regression, multi-block partial least squares regression, and serial partial least squares regression algorithms for the analysis of Fe in iron ore using LIBS , 2012 .

[25]  C. Santhosh,et al.  Analysis of trace elements in complex matrices (soil) by Laser Induced Breakdown Spectroscopy (LIBS) , 2013 .

[26]  R. Russo,et al.  Analytical spectral dependent partial least squares regression: a study of nuclear waste glass from thorium based fuel using LIBS , 2015 .

[27]  Lionel Canioni,et al.  Good practices in LIBS analysis: Review and advices , 2014 .

[28]  Peter Filzmoser,et al.  Introduction to Multivariate Statistical Analysis in Chemometrics , 2009 .

[29]  Philip K. Hopke,et al.  The evolution of chemometrics , 2003 .

[30]  S. Clegg,et al.  Remote laser‐induced breakdown spectroscopy (LIBS) for lunar exploration , 2012 .

[31]  Ron Wehrens,et al.  The pls Package: Principal Component and Partial Least Squares Regression in R , 2007 .

[32]  Yonghoon Lee,et al.  Remote quantitative analysis of cerium through a shielding window by stand-off laser-induced breakdown spectroscopy , 2014 .

[33]  V. B. Kartha,et al.  Evaluation of high-performance liquid chromatography laser-induced fluorescence for serum protein profiling for early diagnosis of oral cancer. , 2010, Journal of biomedical optics.

[34]  Homogeneity testing and quantitative analysis of manganese (Mn) in vitrified Mn-doped glasses by laser-induced breakdown spectroscopy (LIBS) , 2014 .