Impact of a modi fi ed anti-thrombotic guideline on stroke in children supported with a pediatric ventricular assist device

t matter r 2017 I 16/j.healun.2017. vidnr@stanford.ed David Rosenthal, 50 Welch Road, 7913. Fax: +650s (D.N.R. and C. BACKGROUND: Stroke is the most feared complication associated with the Berlin Heart EXCOR pediatric ventricular assist device (VAD), the most commonly used VAD in children, and affects 1 in 3 children. We sought to determine whether a modified anti-thrombotic guideline, involving more intense platelet inhibition and less reliance on platelet function testing, is associated with a lower incidence of stroke. METHODS: All children supported with the EXCOR at Stanford from 2009 to 2014 were divided into 2 cohorts based on the primary anti-thrombotic guideline used to prevent pump thrombosis: (1) the Edmonton Anti-thrombotic Guideline (EG) cohort, which included children implanted before September 2012 when dual anti-platelet therapy was used with doses titrated to Thromboelastrography/ PlateletMapping (TEG/PM); and (2) the Stanford Modified Anti-thrombotic Guideline (SG) cohort, which included children implanted on or after September 2012 when triple anti-platelet therapy was used routinely and where doses were uptitrated to high, weight-based dosing targets, with low-dose steroids administered as needed for inflammation. RESULTS: At baseline, the EG (N 1⁄4 16) and SG (N 1⁄4 11) cohorts were similar. The incidence rate of stroke in the SG cohort was 84% lower than in the EG cohort (0.8 vs 4.9 events per 1,000 days of support, p 1⁄4 0.031), and 86% lower than in the previous Investigational Device Exemption trial (p 1⁄4 0.006). The bleeding rate was also lower in the SG cohort (p 1⁄4 0.015). Target doses of aspirin, clopidogrel and dipyridamole were higher (all p o 0.003), with less dosing variability in the SG cohort than in the EG cohort. There was no difference in adenosine diphosphate inhibition by TEG/PM, but arachidonic acid inhibition was higher in the SG cohort (median 75% vs 39%, p 1⁄4 0.008). CONCLUSIONS: Stroke was significantly less common in pediatric patients supported with the Berlin Heart EXCOR VAD using a triple anti-platelet regimen uptitrated to high, weight-based dosing targets

[1]  C. Fraser,et al.  The miniaturized pediatric continuous‐flow device: Preclinical assessment in the chronic sheep model , 2017, The Journal of thoracic and cardiovascular surgery.

[2]  Gregory Dolin,et al.  8U.S. Food and Drug Administration , 2016 .

[3]  A. Bhutta,et al.  Steroid therapy attenuates acute phase reactant response among children on ventricular assist device support. , 2015, The Annals of thoracic surgery.

[4]  R. Ichord,et al.  Neurological Complications and Outcomes in the Berlin Heart EXCOR® Pediatric Investigational Device Exemption Trial , 2015, Journal of the American Heart Association.

[5]  A. Bhutta,et al.  Incremental reduction in the incidence of stroke in children supported with the Berlin EXCOR ventricular assist device. , 2013, The Annals of thoracic surgery.

[6]  A. Amodeo,et al.  Neurological complications during pulsatile ventricular assistance with the Berlin Heart EXCOR in children: incidence and risk factors. , 2013, Artificial organs.

[7]  E. Blackstone,et al.  Berlin Heart EXCOR Pediatric Ventricular Assist Device for Bridge to Heart Transplantation in US Children , 2013, Circulation.

[8]  T. Singh,et al.  US Trends in Pediatric VAD Utilization: Analysis of Organ Procurement and Transplant Network Data , 2013 .

[9]  T. Singh Prospective trial of a pediatric ventricular assist device. , 2012, The New England journal of medicine.

[10]  Robert H. Bartlett,et al.  Berlin Heart EXCOR Pediatric ventricular assist device Investigational Device Exemption study: study design and rationale. , 2011, American heart journal.

[11]  R. Thiagarajan,et al.  Waiting List Mortality Among Children Listed for Heart Transplantation in the United States , 2009, Circulation.

[12]  W. Morrow,et al.  Preliminary Single Center North American Experience With The Berlin Heart Pediatric EXCOR Device , 2008, ASAIO journal.

[13]  T. Timek,et al.  Pneumatic paracorporeal ventricular assist device in infants and children: initial Stanford experience. , 2007, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[14]  R. Hetzer,et al.  Improvement in survival after mechanical circulatory support with pneumatic pulsatile ventricular assist devices in pediatric patients. , 2006, The Annals of thoracic surgery.

[15]  R. Hetzer,et al.  Pneumatic pulsatile ventricular assist devices in children under 1 year of age. , 2005, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[16]  R. Hetzer,et al.  Circulatory support with pneumatic paracorporeal ventricular assist device in infants and children. , 1998, The Annals of thoracic surgery.

[17]  G. Schwartz,et al.  A simple estimate of glomerular filtration rate in children derived from body length and plasma creatinine , 2004 .