Design of a Breath Analysis System for Diabetes Screening and Blood Glucose Level Prediction

It has been reported that concentrations of several biomarkers in diabetics' breath show significant difference from those in healthy people's breath. Concentrations of some biomarkers are also correlated with the blood glucose levels (BGLs) of diabetics. Therefore, it is possible to screen for diabetes and predict BGLs by analyzing one's breath. In this paper, we describe the design of a novel breath analysis system for this purpose. The system uses carefully selected chemical sensors to detect biomarkers in breath. Common interferential factors, including humidity and the ratio of alveolar air in breath, are compensated or handled in the algorithm. Considering the intersubject variance of the components in breath, we build subject-specific prediction models to improve the accuracy of BGL prediction. A total of 295 breath samples from healthy subjects and 279 samples from diabetic subjects were collected to evaluate the performance of the system. The sensitivity and specificity of diabetes screening are 91.51% and 90.77%, respectively. The mean relative absolute error for BGL prediction is 21.7%. Experiments show that the system is effective and that the strategies adopted in the system can improve its accuracy. The system potentially provides a noninvasive and convenient method for diabetes screening and BGL monitoring as an adjunct to the standard criteria.

[1]  David Zhang,et al.  A Novel Breath Analysis System Based on Electronic Olfaction , 2010, IEEE Transactions on Biomedical Engineering.

[2]  M. Phillips,et al.  Increased breath biomarkers of oxidative stress in diabetes mellitus. , 2004, Clinica chimica acta; international journal of clinical chemistry.

[3]  Silvia Coradeschi,et al.  Direct Identification of Bacteria in Blood Culture Samples Using an Electronic Nose , 2010, IEEE Transactions on Biomedical Engineering.

[4]  Simone Meinardi,et al.  Breath ethanol and acetone as indicators of serum glucose levels: an initial report. , 2005, Diabetes technology & therapeutics.

[5]  S Lenzi,et al.  Monitoring breath during oral glucose tolerance tests , 2013, Journal of breath research.

[6]  Edward J. Wolfrum,et al.  Metal Oxide Sensor Arrays for the Detection, Differentiation, and Quantification of Volatile Organic Compounds at Sub-Parts-Per-Million Concentration Levels , 2006 .

[7]  Kiyokatsu Jinno,et al.  Breath acetone analysis with miniaturized sample preparation device: in-needle preconcentration and subsequent determination by gas chromatography-mass spectroscopy. , 2009, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[8]  Guangming Lu,et al.  Non-invasive blood glucose monitoring for diabetics by means of breath signal analysis , 2012 .

[9]  D. Blake,et al.  The clinical potential of exhaled breath analysis for diabetes mellitus. , 2012, Diabetes research and clinical practice.

[10]  David Zhang,et al.  A novel breath analysis system for diabetes diagnosis , 2012, 2012 International Conference on Computerized Healthcare (ICCH).

[11]  David Smith,et al.  Breath acetone concentration; biological variability and the influence of diet , 2011, Physiological measurement.

[12]  Chih-Jen Lin,et al.  LIBSVM: A library for support vector machines , 2011, TIST.

[13]  Ali Osman Selvi,et al.  Electronic Nose System Based on Quartz Crystal Microbalance Sensor for Blood Glucose and HbA1c Levels From Exhaled Breath Odor , 2013, IEEE Sensors Journal.

[14]  Christopher Walton,et al.  Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps , 2009, Journal of breath research.

[15]  S. Pratsinis,et al.  Correlations between blood glucose and breath components from portable gas sensors and PTR-TOF-MS , 2013, Journal of breath research.

[16]  W. Cao,et al.  Current Status of Methods and Techniques for Breath Analysis , 2007 .

[17]  P. Wang,et al.  A novel method for diabetes diagnosis based on electronic nose. , 1997, Biosensors & bioelectronics.

[18]  D. Blake,et al.  Improved predictive models for plasma glucose estimation from multi-linear regression analysis of exhaled volatile organic compounds. , 2009, Journal of applied physiology.

[19]  R. Gutierrez-Osunaa,et al.  Transient response analysis for temperature-modulated chemoresistors , 2003 .

[20]  H. Byun,et al.  Analysis of diabetic patient's breath with conducting polymer sensor array , 2005 .

[21]  S. Hosseini-Golgoo,et al.  Assessing the diagnostic information in the response patterns of a temperature-modulated tin oxide gas sensor , 2011 .

[22]  J. Deslypere,et al.  A new non-invasive technology to screen for dysglycaemia including diabetes. , 2010, Diabetes research and clinical practice.

[23]  Claire Turner,et al.  Potential of breath and skin analysis for monitoring blood glucose concentration in diabetes , 2011, Expert review of molecular diagnostics.

[24]  K. R. Kashwan,et al.  Robust electronic-nose system with temperature and humidity drift compensation for tea and spice flavour discrimination , 2005, 2005 Asian Conference on Sensors and the International Conference on New Techniques in Pharmaceutical and Biomedical Research.

[25]  Julian King,et al.  Measurement of endogenous acetone and isoprene in exhaled breath during sleep , 2012, Physiological measurement.

[26]  D. Blake,et al.  Exhaled methyl nitrate as a noninvasive marker of hyperglycemia in type 1 diabetes , 2007, Proceedings of the National Academy of Sciences.

[27]  M. Shepherd,et al.  A Study on Breath Acetone in Diabetic Patients Using a Cavity Ringdown Breath Analyzer: Exploring Correlations of Breath Acetone With Blood Glucose and Glycohemoglobin A1C , 2010, IEEE Sensors Journal.

[28]  Bernhard Schölkopf,et al.  A tutorial on support vector regression , 2004, Stat. Comput..

[29]  W. Ping,et al.  A novel method for diabetes diagnosis based on electronic nose. , 1997 .

[30]  P. Barnes,et al.  Exhaled carbon monoxide levels elevated in diabetes and correlated with glucose concentration in blood: a new test for monitoring the disease? , 1999, Chest.

[31]  T. H. Risby CURRENT STATUS OF CLINICAL BREATH ANALYSIS , 2005 .

[32]  Amir Amini,et al.  Improving gas identification accuracy of a temperature-modulated gas sensor using an ensemble of classifiers , 2013 .

[33]  X. Zhang,et al.  Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization. , 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[34]  David Zhang,et al.  Sensor Evaluation in a Breath Analysis System , 2014, 2014 International Conference on Medical Biometrics.

[35]  Yuh-Jiuan Lin,et al.  Application of the electronic nose for uremia diagnosis , 2001 .

[36]  E. Martinelli,et al.  Identification of schizophrenic patients by examination of body odor using gas chromatography-mass spectrometry and a cross-selective gas sensor array. , 2005, Medical science monitor : international medical journal of experimental and clinical research.

[37]  G. Teschl,et al.  Isoprene and acetone concentration profiles during exercise on an ergometer , 2009, Journal of breath research.

[38]  Q. Zhang,et al.  Diagnosis of diabetes by image detection of breath using gas-sensitive LAPS. , 2000, Biosensors & bioelectronics.

[39]  S. K. Vashist Non-invasive glucose monitoring technology in diabetes management: a review. , 2012, Analytica chimica acta.

[40]  D. Goldstein,et al.  Defining the relationship between plasma glucose and HbA(1c): analysis of glucose profiles and HbA(1c) in the Diabetes Control and Complications Trial. , 2002, Diabetes care.

[41]  A. Hierlemann,et al.  Higher-order Chemical Sensing , 2007 .

[42]  H. Paretzke,et al.  Differences in exhaled gas profiles between patients with type 2 diabetes and healthy controls. , 2010, Diabetes technology & therapeutics.