Optical Measurement of Blood Oxygen Saturation of Dental Pulp

The applicability of arterial pulse oximetry to dental pulp was demonstrated using in vitro and in vivo measurements. First, porcine blood of known oxygen saturation (SO2) was circulated through extracted human upper incisors, while transmitted-light plethysmography was performed using three different visible wavelengths. From the light intensity waveforms measured in vitro, a parameter that is statistically correlated to SO2 was calculated using the pulsatile/nonpulsatile component ratios of two wavelengths for different SO2. Then, values were measured in vivo for living incisors, and the corresponding SO2 values were calculated using the results of in vitro measurements. The estimated SO2 values of the upper central incisors measured in vivo were from 71.0 to 92.7%. This study showed the potential to measure the oxygen saturation changes to identify the sign of pulpal inflammation.

[1]  J. Schmitt,et al.  Optical determination of dental pulp vitality , 1991, IEEE Transactions on Biomedical Engineering.

[2]  Y. Mahler,et al.  Dental pulp photoplethysmography in human beings. , 1973, Oral surgery, oral medicine, and oral pathology.

[3]  Y. Shimada,et al.  Spectrophotometric monitoring of arterial oxygen saturation in the fingertip , 2006, Medical and Biological Engineering and Computing.

[4]  Amitha M Hegde,et al.  Pulse oximetry: a diagnostic instrument in pulpal vitality testing. , 2002, The Journal of clinical pediatric dentistry.

[5]  J. Andreasen,et al.  Influence of maturation status and tooth type of permanent teeth upon electrometric and thermal pulp testing. , 1976, Scandinavian journal of dental research.

[6]  W. Felippe,et al.  Assessment of pulp blood flow in primary and permanent teeth using pulse oximetry. , 2011, Dental traumatology : official publication of International Association for Dental Traumatology.

[7]  Zenzo Miwa,et al.  Pulpal blood flow in vital and nonvital young permanent teeth measured by transmitted-light photoplethysmography: a pilot study. , 2002, Pediatric dentistry.

[8]  H Horiuchi,et al.  Optical characteristics of human extracted teeth and the possible application of photoplethysmography to the human pulp. , 1994, Archives of oral biology.

[9]  J M Schnettler,et al.  Pulse oximetry as a diagnostic tool of pulpal vitality. , 1991, Journal of endodontics.

[10]  Harri K. Kopola,et al.  Novel fiber optic dental pulp vitalometer , 1995, Other Conferences.

[11]  B. Chew,et al.  Evaluation of optical methods of detecting dental pulp vitality. , 1997, Journal of biomedical optics.

[12]  H. Klein Pulp responses to an electric pulp stimulator in the developing permanent anterior dentition. , 1978, ASDC journal of dentistry for children.

[13]  S. Takatani,et al.  Absolute transmitted light plethysmography for assessment of dental pulp vitality through quantification of pulp chamber hematocrit by a three-layer model. , 2008, Journal of biomedical optics.

[14]  K. Gulabivala,et al.  Evaluation of a pulse oximeter and customized probe for pulp vitality testing. , 1996, Journal of endodontics.

[15]  B Gazelius,et al.  Restored vitality in luxated teeth assessed by laser Doppler flowmeter. , 1988, Endodontics & dental traumatology.

[16]  C. Goho Pulse oximetry evaluation of vitality in primary and immature permanent teeth. , 1999, Pediatric dentistry.

[17]  B. Chance,et al.  Dual wavelength spectrophotometry as a diagnostic test of the pulp chamber contents. , 1992, Oral surgery, oral medicine, and oral pathology.

[18]  B. Gazelius,et al.  Non-invasive recording of blood flow in human dental pulp. , 1986, Endodontics & dental traumatology.