Application of polymer-coated glassy carbon electrodes to the direct determination of trace metals in body fluids by anodic stripping voltammetry.

This paper describes the use of a polymer-coated thin mercury film electrode for the direct determination of trace metals in body fluids by anodic stripping voltametry. The antifouling properties of the membrane coating greatly improve the analytical signal in comparison with the conventional thin mercury film electrode. Lead in whole blood, urine, and sweat and copper in sweat can be determined accurately with sample acidification as the only pretreatment step, while the determination of copper in serum requires sample deproteination prior to analysis. Owing to an improved procedure for the preparation of the perfluorosulfonated membrane, the lifetime of the electrode is at least one working day when used continuously in acidified body fluids.

[1]  C. R. Martin,et al.  Procedure for preparing solution-cast perfluorosulfonate ionomer films and membranes , 1986 .

[2]  J. Stauber,et al.  The determination of trace metals in sweat by anodic stripping voltammetry. , 1987, The Science of the total environment.

[3]  P. Ostapczuk,et al.  Rapid and reliable determination of elevated blood lead levels , 1984 .

[4]  C. R. Martin,et al.  Dissolution of perfluorinated ion-containing polymers , 1982 .

[5]  Graeme E. Batley,et al.  Application of polymer-coated glassy carbon electrodes in anodic stripping voltammetry , 1987 .

[6]  A. Bond,et al.  A simple pretreatment of unrine for the direct differential-pulse anodic stripping voltammetric determination of lead , 1984 .

[7]  B. Hoyer,et al.  Evaluation of single-point calibration in flow potentiometric stripping analysis. , 1986, Talanta.

[8]  P. Brezonik,et al.  Trace metal analysis by anodic stripping voltammetry: effect of sorption by natural and model organic compounds , 1976 .

[9]  J. H. Christie,et al.  Analytical applications of pulsed voltammetric stripping at thin film mercury electrodes , 1973 .

[10]  M. Oehme,et al.  Comparison of digestion procedures for the determination of heavy metals (Cd, Cu, Pb) in blood by anodic stripping voltammetry , 1979 .

[11]  W. Lund,et al.  The determination of cadmium, lead and copper in urine by differential pulse anodic stripping voltammetry , 1979 .

[12]  D. Luo,et al.  Effect of surface-active compounds on voltammetric stripping analysis at the mercury film electrode. , 1984, Talanta.

[13]  M. Josefson,et al.  Simultaneous determination of cadmium and lead in urine by means of computerized potentiometric stripping analysis , 1981 .

[14]  L. Danielsson,et al.  Potentiometric stripping analysis for lead in urine , 1979 .

[15]  G. Batley,et al.  The effect of dissolved organics on the stripping voltammetry of seawater , 1976 .

[16]  M. Josefson,et al.  Simultaneous determination of cadmium and lead in whole blood and serum by computerized potentiometric stripping analysis. , 1981, Analytical chemistry.

[17]  R. Boeckx Lead poisoning in children. , 1986, Analytical Chemistry.

[18]  T. Florence Comparison of linear scan and differential pulse anodic stripping voltammetry at a thin mercury film glassy carbon electrode , 1980 .

[19]  R. A. Zeeuw,et al.  TOXIC METAL ANALYSIS BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY IN CLINICAL AND FORENSIC TOXICOLOGY , 1977 .

[20]  Joseph Wang Stripping analysis of trace metals in human body fluids , 1982 .