Acoustic dipole radiation based electrical impedance contrast imaging approach of magnetoacoustic tomography with magnetic induction.

PURPOSE Different from the theory of acoustic monopole spherical radiation, the acoustic dipole radiation based theory introduces the radiation pattern of Lorentz force induced dipole sources to describe the principle of magnetoacoustic tomography with magnetic induction (MAT-MI). Although two-dimensional (2D) simulations have been studied for cylindrical phantom models, layer effects of the dipole sources within the entire object along the z direction still need to be investigated to evaluate the performance of MAT-MI for different geometric specifications. The purpose of this work is further verifying the validity and generality of acoustic dipole radiation based theory for MAT-MI with two new models in different shapes, dimensions, and conductivities. METHODS Based on the theory of acoustic dipole radiation, the principles of MAT-MI were analyzed with derived analytic formulae. 2D and 3D numerical studies for two new models of aluminum foil and cooked egg were conducted to simulate acoustic pressures and corresponding waveforms, and 2D images of the scanned layers were reconstructed with the simplified back projection algorithm for the waveforms collected around the models. The spatial resolution for conductivity boundary differentiation was also analyzed with different foil thickness. For comparison, two experimental measurements were conducted for a cylindrical aluminum foil phantom and a shell-peeled cooked egg. The collected waveforms and the reconstructed images of the scanned layers were achieved to verify the validation of the acoustic dipole radiation based theory for MAT-MI. RESULTS Despite the difference between the 2D and 3D simulated pressures, good consistence of the collected waveforms proves that wave clusters are generated by the abrupt pressure changes with bipolar vibration phases, representing the opposite polarities of the conductivity changes along the measurement direction. The configuration of the scanned layer can be reconstructed in terms of shape and size, and the conductivity boundaries are displayed in stripes with different contrast and bipolar intensities. Layer effects are demonstrated to have little influence on the collected waveforms and the reconstructed images of the scanned layers for the two new models. The experimental results have good agreements with numerical simulations, and the reconstructed 2D images provide conductivity configurations in the scanned layers of the aluminum foil and the egg models. CONCLUSIONS It can be concluded that the acoustic pressure of MAT-MI is produced by the divergence of the induced Lorentz force, and the collected waveforms comprise wave clusters with bipolar vibration phases and different amplitudes, providing the information of conductivity boundaries in the scanned layer. With the simplified back projection algorithm for diffraction sources, collected waveforms can be used to reconstruct 2D conductivity contrast image and the conductivity configuration in the scanned layer can be obtained in terms of shape and size in stripes with the spatial resolution of the acoustic wavelength. The favorable results further verify the validity and generality of the acoustic dipole radiation based theory and suggest the feasibility of MAT-MI as an effective electrical impedance contrast imaging approach for medical imaging.

[1]  Feng Zhang,et al.  Acoustic dipole radiation based conductivity image reconstruction for magnetoacoustic tomography with magnetic induction , 2012 .

[2]  Keith Paulsen,et al.  Using multiple-electrode impedance measurements to monitor cryosurgery. , 2002, Medical physics.

[3]  Bin He,et al.  Magnetoacoustic tomography with magnetic induction (MAT-MI) , 2005, Physics in medicine and biology.

[4]  Chao Tao,et al.  Photoacoustic tomography of tissue subwavelength microstructure with a narrowband and low frequency system , 2012 .

[5]  Hui Xia,et al.  A New Imaging Logging Technology Based on Magnetoacoustic Tomography with Magnetic Induction , 2012 .

[6]  Huabei Jiang,et al.  Transport-based quantitative photoacoustic tomography: simulations and experiments , 2010, Physics in medicine and biology.

[7]  Manojit Pramanik,et al.  Design and evaluation of a novel breast cancer detection system combining both thermoacoustic (TA) and photoacoustic (PA) tomography. , 2008, Medical physics.

[8]  Bin He,et al.  Noninvasive Imaging of Bioimpedance Distribution by Means of Current Reconstruction Magnetic Resonance Electrical Impedance Tomography , 2008, IEEE Transactions on Biomedical Engineering.

[9]  Eung Je Woo,et al.  Magnetic Resonance Electrical Impedance Tomography (MREIT) , 2011, SIAM Rev..

[10]  Minghua Xu,et al.  Exact frequency-domain reconstruction for thermoacoustic tomography. II. Cylindrical geometry , 2002, IEEE Transactions on Medical Imaging.

[11]  Y Ziya Ider,et al.  Algebraic reconstruction for 3D magnetic resonance-electrical impedance tomography (MREIT) using one component of magnetic flux density. , 2004, Physiological measurement.

[12]  Bin He,et al.  Magnetoacoustic imaging of human liver tumor with magnetic induction. , 2011, Applied physics letters.

[13]  D. C. Barber,et al.  Three-dimensional electrical impedance tomography , 1996, Nature.

[14]  T K Hames,et al.  Spectral expansion analysis in electrical impedance tomography , 1991 .

[15]  D. Xing,et al.  Three-dimensional thermoacoustic imaging for early breast cancer detection. , 2012, Medical physics.

[16]  Ma Qing-yu,et al.  Two-Dimensional Lorentz Force Image Reconstruction for Magnetoacoustic Tomography with Magnetic Induction , 2010 .

[17]  Minghua Xu,et al.  Time-domain reconstruction algorithms and numerical simulations for thermoacoustic tomography in various geometries , 2003, IEEE Transactions on Biomedical Engineering.

[18]  Bin He,et al.  Solving the forward problem of magnetoacoustic tomography with magnetic induction by means of the finite element method , 2009, Physics in medicine and biology.

[19]  Zhang Dong,et al.  Acoustic dipole radiation model for magnetoacoustic tomography with magnetic induction , 2011 .

[20]  Xu Li,et al.  Imaging Electrical Impedance From Acoustic Measurements by Means of Magnetoacoustic Tomography With Magnetic Induction (MAT-MI) , 2007, IEEE Transactions on Biomedical Engineering.

[21]  Kevin Paulson,et al.  Optimal experiments in electrical impedance tomography , 1993, IEEE Trans. Medical Imaging.

[22]  Da Xing,et al.  Full-field 3D photoacoustic imaging based on plane transducer array and spatial phase-controlled algorithm. , 2011, Medical physics.

[23]  Bin He,et al.  Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction. , 2007, Applied physics letters.

[24]  Da Xing,et al.  Thermoacoustic molecular tomography with magnetic nanoparticle contrast agents for targeted tumor detection. , 2010, Medical physics.

[25]  Lihong V. Wang,et al.  Photoacoustic Tomography: In Vivo Imaging from Organelles to Organs , 2012, Science.

[26]  H. Wen,et al.  Volumetric Hall Effect Tomography — A Feasibility Study , 1999, Ultrasonic imaging.