Fibre recruitment and shape changes of knee ligaments during motion: as revealed by a computer graphics-based model.

A computer graphics-based model of the knee ligaments in the sagittal plane was developed for the simulation and visualization of the shape changes and fibre recruitment process of the ligaments during motion under unloaded and loaded conditions. The cruciate and collateral ligaments were modelled as ordered arrays of fibres which link attachment areas on the tibia and femur. Fibres slacken and tighten as the ligament attachment areas on the bones rotate and translate relative to each other. A four-bar linkage, composed of the femur, tibia and selected isometric fibres of the two cruciates, was used to determine the motion of the femur relative to the tibia during passive (unloaded) movement. Fibres were assumed to slacken in a Euler buckling mode when the distances between their attachments are less than chosen reference lengths. The ligament shape changes and buckling patterns are demonstrated with computer graphics. When the tibia is translated anteriorly or posteriorly relative to the femur by muscle forces and external loads, some ligament fibres tighten and are recruited progressively to transmit increasing shear forces. The shape changes and fibre recruitment patterns predicted by the model compare well qualitatively with experimental results reported in the literature. The computer graphics approach provides insight into the micro behaviour of the knee ligaments. It may help to explain ligament injury mechanisms and provide useful information to guide the design of ligament replacements.

[1]  F.E. Zajac,et al.  An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures , 1990, IEEE Transactions on Biomedical Engineering.

[2]  Freddie H. Fu,et al.  Determination of the in situ loads on the human anterior cruciate ligament , 1993, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[3]  E Y Chao,et al.  Direct in vivo tendon force measurement system. , 1990, Journal of biomechanics.

[4]  L Blankevoort,et al.  Recruitment of knee joint ligaments. , 1991, Journal of biomechanical engineering.

[5]  F. Girgis,et al.  The cruciate ligaments of the knee joint. Anatomical, functional and experimental analysis. , 1975, Clinical orthopaedics and related research.

[6]  A. Amis,et al.  Functional anatomy of the anterior cruciate ligament. Fibre bundle actions related to ligament replacements and injuries. , 1991, The Journal of bone and joint surgery. British volume.

[7]  D. N. Pinder,et al.  In vivo tendon tension and bone strain measurement and correlation. , 1974, Journal of biomechanics.

[8]  E Y Chao,et al.  Simulation and animation of musculoskeletal joint system. , 1993, Journal of biomechanical engineering.

[9]  A B Zavatsky,et al.  A Model of Human Knee Ligaments in the Sagittal Plane: Part 2: Fibre Recruitment under Load , 1992, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[10]  J B Morrison,et al.  The mechanics of the knee joint in relation to normal walking. , 1970, Journal of biomechanics.

[11]  C. Schneck,et al.  Testing for isometry during reconstruction of the anterior cruciate ligament. Anatomical and biomechanical considerations. , 1990, The Journal of bone and joint surgery. American volume.

[12]  J L Lewis,et al.  A note on the application and evaluation of the buckle transducer for the knee ligament force measurement. , 1982, Journal of biomechanical engineering.

[13]  O. Brantigan,et al.  THE MECHANICS OF THE LIGAMENTS AND MENISCI OF THE KNEE JOINT , 1941 .

[14]  J. O'Connor,et al.  Three-Dimensional Geometrical Models of Human Knee Ligaments , 1994 .

[15]  J. Collins,et al.  Muscle-Ligament Interactions at the Knee during Walking , 1991, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[16]  A B Zavatsky,et al.  A Model of Human Knee Ligaments in the Sagittal Plane: Part 1: Response to Passive Flexion , 1992, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[17]  John J. O'Connor,et al.  A three-dimensional geometric model of the knee for the study of joint forces in gait , 1997 .

[18]  R van Dijk,et al.  Roentgen stereophotogrammetric methods for the evaluation of the three dimensional kinematic behaviour and cruciate ligament length patterns of the human knee joint. , 1979, Journal of biomechanics.

[19]  S L Woo,et al.  The effects of knee motion and external loading on the length of the anterior cruciate ligament (ACL): a kinematic study. , 1991, Journal of biomechanical engineering.

[20]  J P Boysen,et al.  Interactive computer graphics in the study of human body planar motion under free fall conditions. , 1977, Journal of biomechanics.

[21]  T L Shercliff,et al.  The Geometry of the Knee in the Sagittal Plane , 1989, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[22]  K. Markolf,et al.  Stiffness and laxity of the knee--the contributions of the supporting structures. A quantitative in vitro study. , 1976, The Journal of bone and joint surgery. American volume.