Effect of Ambient Light on Near Infrared Spectroscopy

Background: Concerns have been raised about the ability of Near Infrared Spectroscopy (NIRS) to monitor skeletal tissue regional oxygen saturation (rSO2) in excessive light conditions, as are found under the overhead lights of the operating room. This study seeks to determine whether varying intensities of ambient light exert an influence on NIRS measurements of skeletal tissue rSO2. Methods: Thirty people were recruited from the staff of a local surgical center to participate in the study. Three separate NIRS devices (Covidien INVOS Cerebral Oximeter 510°C, Nonin EQUANOX Model 7600, and a CASMED MC-2030C Cerebral Oximeter) were used to obtain readings from the anterior compartment of the leg. Illuminance was recorded simultaneously with oximetry data in an operating room with (1) no lights on, (2) room lights, and (3) surgical lamps set to maximal intensity. Results: No differences were seen in rSO2 values under the different lighting conditions while using the Nonin device. There was a statistically significant difference between rSO2 for lights off versus room lights (-0.933, p=0.0045) as well as for lights off versus operating room (OR) lamps (level 5) (-0.50, p=0.0035) for the INVOS device, although the INVOS device was not always able to produce a reading in the presence of high-intensity OR light. While there was no difference found between lights off and room lights when using the CASMED device, it was unable to display a value in the presence of high-intensity OR lamp light. Conclusions: The results indicate that the presence of light has an effect on oximetry readings; however, the presence of such an effect is dependent upon the device being used. While other applications of the device, such as cerebral oximetry, may allow for drapes to cover the areas being monitored, monitoring for compartment syndrome of the leg would not be as forgiving. This application would be best served by a device capable of monitoring at all light levels.

[1]  T. Whitesides,et al.  Near-infrared spectroscopy in lower extremity trauma. , 2009, The Journal of bone and joint surgery. American volume.

[2]  Rainer Künnemeyer,et al.  Temperature dependence of near-infrared spectra of whole blood. , 2008, Journal of biomedical optics.

[3]  W. Colier,et al.  Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle. , 2001, Clinical science.

[4]  D T Delpy,et al.  The Noninvasive Measurement of Absolute Cerebral Deoxyhemoglobin Concentration and Mean Optical Path Length in the Neonatal Brain by Second Derivative Near Infrared Spectroscopy , 1996, Pediatric Research.

[5]  B. Reichart,et al.  Optimizing cerebral oxygenation during cardiac surgery: a review of experimental and clinical investigations with near infrared spectrophotometry. , 2000, The Thoracic and cardiovascular surgeon.

[6]  H. Yonas,et al.  Noninvasive Continuous Monitoring of Cerebral Oxygenation Periictally Using Near‐Infrared Spectroscopy: A Preliminary Report , 1999, Epilepsia.

[7]  T. Whitesides,et al.  Correlation between muscle oxygenation and compartment pressures in acute compartment syndrome of the leg. , 2010, The Journal of bone and joint surgery. American volume.

[8]  Eiji Okada,et al.  Influence of adipose tissue on muscle oxygenation measurement with an NIRS instrument , 1998, European Conference on Biomedical Optics.

[9]  Quantitative near-infrared spectroscopy in human skeletal muscle : methodological issues and clinical application , 2002 .

[10]  M. Mckenney,et al.  Utility of near-infrared spectroscopy in the diagnosis of lower extremity compartment syndrome. , 1999, The Journal of trauma.

[11]  E. B. Wassenaar,et al.  Reliability of Near-Infrared Spectroscopy in People With Dark Skin Pigmentation , 2005, Journal of Clinical Monitoring and Computing.

[12]  M. Ferrari,et al.  Noninvasive measurement of forearm blood flow and oxygen consumption by near-infrared spectroscopy. , 1994, Journal of applied physiology.

[13]  M. Leone,et al.  Optical absorption spectra of deoxy- and oxyhemoglobin in the temperature range 300-20 K. Relation with protein dynamics. , 1986, Biophysical chemistry.