Retrofit design of a boil-off gas handling process in liquefied natural gas receiving terminals

Generation of Boil-off gas (BOG) in liquefied natural gas (LNG) receiving terminals considerably affects operating costs and the safety of the facility. For the above reasons, a proper BOG handling process is a major determinant in the design of a LNG receiving terminal. This study proposes the concept of a retrofit design for a BOG the handling process using a fundamental analysis. A base design was determined for a minimum send-out case in which the BOG handling becomes the most difficult. In the proposed design, the cryogenic energy of the LNG stream is used to cool other streams inside the process. It leads to a reduction in the operating costs of the compressors in the BOG handling process. Design variables of the retrofit design were optimized with non-linear programming to maximize profitability. Optimization results were compared with the base design to show the effect of the proposed design. The proposed design provides a 22.7% energy saving ratio and a 0.176 year payback period.

[1]  Hongguang Jin,et al.  Novel cogeneration power system with liquefied natural gas (LNG) cryogenic exergy utilization , 2004 .

[2]  South Korea,et al.  REVIEW ON ECONOMICAL EFFICIENCY OF LNG COLD ENERGY USE IN SOUTH KOREA , 2006 .

[3]  Chonghun Han,et al.  Synthesis of Unloading Operation Procedure for a Mixed Operation of Above-Ground and In-Ground Liquefied Natural Gas Storage Tanks Using Dynamic Simulation , 2010 .

[4]  Chaowei Liu,et al.  Thermodynamic-Analysis-Based Design and Operation for Boil-Off Gas Flare Minimization at LNG Receiving Terminals , 2010 .

[5]  Wang Qiang,et al.  Exergy analysis of liquefied natural gas cold energy recovering cycles , 2005 .

[6]  Chonghun Han,et al.  Optimization of the Operation of Boil-Off Gas Compressors at a Liquified Natural Gas Gasification Plant , 2007 .

[7]  S. Dharmadhikari Optimize LNG vaporizers , 2004 .

[8]  Lei Jia,et al.  Performance of cryogenic thermoelectric generators in LNG cold energy utilization , 2005 .

[9]  J. Szargut,et al.  Utilization of the cryogenic exergy of liquid natural gas (LNG) for the production of electricity , 2009 .

[10]  I K Yoon,et al.  Study on the improvement of BOG recondensation process at LNG receving terminal , 2001 .

[11]  E. Querol,et al.  Boil off gas (BOG) management in Spanish liquid natural gas (LNG) terminals , 2010 .

[12]  En Sup Yoon,et al.  Dynamic simulation and optimization of the operation of boil-off gas compressors in a liquefied natural gas gasification plant , 2011 .

[13]  Chonghun Han,et al.  Methodology for Stable Dynamic Simulation of a LNG Pipe under Two-Phase-Flow Generation , 2010 .

[14]  Hongtan Liu,et al.  Characteristics and applications of the cold heat exergy of liquefied natural gas , 1999 .

[15]  Sanggyu Lee Operating Information System for LNG Facilities , 2001 .

[16]  Wang Qiang,et al.  Analysis of power cycle based on cold energy of liquefied natural gas and low-grade heat source , 2004 .

[17]  Chonghun Han,et al.  Optimization of recirculation operating in liquefied natural gas receiving terminal , 2010 .