A new noninvasive method to measure blood pressure: results of a multicenter trial.

BACKGROUND Blood pressure (BP) monitoring with arterial waveform display requires an arterial cannula. We evaluated a new noninvasive device, Vasotrac (Medwave, Arden Hills, MN) that provides BP measurements approximately every 12-15 beats and displays pulse rate and a calibrated arterial waveform for each BP measurement. METHODS Surgical and critically ill patients (n = 80) served as subjects for the study. BPs, pulse waveforms, and pulse rates measured via a radial artery catheter were compared with those obtained by the Vasotrac from the opposite radial artery. Data were analyzed to determine agreement between the two systems of measurement. RESULTS Blood pressure measured noninvasively by the Vasotrac demonstrated excellent correlation (P<0.01) with BP measured via a radial arterial catheter (systolic r2 = 0.93; diastolic r2 = 0.89; mean r2 = 0.95). Differences in BP measured by the Vasotrac versus the radial arterial catheter were small. The mean+/-SD bias and precision were as follows: systolic BP 0.02+/-5.4 mm Hg and 3.9+/-3.7 mm Hg; diastolic BP -0.39+/-3.9 mm Hg and 2.7+/-2.8 mm Hg; mean BP -0.21+/-3.0 mm Hg and 2.1+/-2.2 mm Hg compared with radial artery measurements. The Vasotrac pulse rates were almost identical to those measured directly (r2 = 0.95). The Vasotrac BP waveform resembled those directly obtained radial artery pulsatile waveforms. CONCLUSIONS In surgical and critically ill patients, the Vasotrac measured BP, pulse rate, and displayed radial artery waveform, which was similar to direct radial arterial measurements. It should be a suitable device to measure BP frequently in a noninvasive fashion.

[1]  A. Showman,et al.  Hazard of automatic noninvasive blood pressure monitoring. , 1981, Anesthesiology.

[2]  K H Wesseling Finger arterial pressure measurement with Finapres. , 1996, Zeitschrift fur Kardiologie.

[3]  T. Quill,et al.  The accuracy of rapid oscillometric blood pressure determination. , 1990, Biomedical instrumentation & technology.

[4]  T Yamamura,et al.  Arterial tonometry for noninvasive, continuous blood pressure monitoring during anesthesia. , 1991, Anesthesiology.

[5]  W. P. Sy Ulnar nerve palsy possibly related to use of automatically cycled blood pressure cuff. , 1981, Anesthesia and analgesia.

[6]  Z. Żylicz,et al.  Postoperative ulnar neuropathy after kidney transplantation , 1983, Anaesthesia.

[7]  J. Brock‐Utne,et al.  Comparison of Arterial Tonometry with Radial Artery Catheter Measurements of Blood Pressure in Anesthetized Patients , 1994, Anesthesiology.

[8]  Wesseling Kh Finger arterial pressure measurement with Finapres. , 1996 .

[9]  R M Gardner,et al.  Direct blood pressure measurement--dynamic response requirements. , 1981, Anesthesiology.

[10]  M. Ueda [Clinical evaluation of arterial tonometry for noninvasive, continuous blood pressure monitoring during anesthesia]. , 1989, [Hokkaido igaku zasshi] The Hokkaido journal of medical science.

[11]  E. Frezza,et al.  Indications and complications of arterial catheter use in surgical or medical intensive care units: analysis of 4932 patients. , 1998, The American surgeon.