Time-resolved non-contact fluorescence diffuse optical tomography measurements with ultra-fast time-correlated single photon counting avalanche photodiodes

The design and fabrication of time-correlated single photon counting (TCSPC) avalanche photodiodes (APDs) and associated quenching circuits have made significant progresses in recent years. APDs with temporal resolutions comparable to microchannel plate photomultiplier tubes (MCP-PMTs) are now available. MCP-PMTs were until these progresses the best TCSPC detectors with timing resolutions down to 30ps. APDs can now achieve these resolutions at a fraction of the cost. Work is under way to make the manufacturing of TCSPC APDs compatible with standard electronics fabrication practices. This should allow to further reduce their cost and render them easier to integrate in complex multi-channel TCSPC electronics, as needed in diffuse optical tomography (DOT) systems. Even if their sensitive area is much smaller than that of the ubiquitous PMT used in TCSPC, we show that with appropriate selection of optical components, TCSPC APDs can be used in time-domain DOT. To support this, we present experimental data and calculations clearly demonstrating that comparable measurements can be obtained with APDs and PMTs. We are, to our knowledge, the first group using APDs in TD DOT, in particular in non-contact TD fluorescence DOT.

[1]  Alessandro Torricelli,et al.  Compact time-resolved reflectance system for dual-wavelength multichannel assessment of tissue absorption and scattering , 1999, Photonics West - Biomedical Optics.

[2]  D. Delpy,et al.  A 32-channel time-resolved instrument for medical optical tomography , 2000 .

[3]  Maria Lepore,et al.  Optical property measurements in scattering media by time-correlated single-photon counting system (TCSPCS) , 2000, European Conference on Biomedical Optics.

[4]  M S Feld,et al.  Fluorescence tomographic imaging in turbid media using early-arriving photons and Laplace transforms. , 1997, Proceedings of the National Academy of Sciences of the United States of America.

[5]  Feng Gao,et al.  Time-resolved diffuse optical tomographic imaging for the provision of both anatomical and functional information about biological tissue. , 2005, Applied optics.

[6]  Vasilis Ntziachristos,et al.  Complete-angle projection diffuse optical tomography by use of early photons. , 2005, Optics letters.

[7]  J. Wiza Microchannel plate detectors , 1979 .

[8]  J. Ripoll,et al.  Fast analytical approximation for arbitrary geometries in diffuse optical tomography. , 2002, Optics letters.

[9]  O. Steinkellner,et al.  Development of a multi-channel time-domain fluorescence mammograph , 2007, SPIE BiOS.

[10]  Simon R. Arridge,et al.  Multi-dimensional time-correlated single photon counting applied to diffuse optical tomography , 2005, SPIE BiOS.

[11]  Franco Zappa,et al.  A view on progress of silicon single-photon avalanche diodes and quenching circuits , 2006, SPIE Optics East.

[12]  Wolfgang Becker,et al.  Multidimensional time-correlated single photon counting , 2006, SPIE Optics East.

[13]  W. Becker Advanced Time-Correlated Single Photon Counting Techniques , 2005 .

[14]  Patrick Poulet,et al.  An instrument for small-animal imaging using time-resolved diffuse and fluorescence optical methods , 2006 .

[15]  R. Stephenson A and V , 1962, The British journal of ophthalmology.

[16]  Vincent Robichaud,et al.  Time-resolved fluorescence measurements for diffuse optical tomography using ultrafast time-correlated single photon counting , 2006, SPIE Optics East.

[17]  Britton Chance,et al.  TIME-CORRELATED SINGLE PHOTON COUNTING IMAGER FOR SIMULTANEOUS MAGNETIC RESONANCE AND NEAR-INFRARED MAMMOGRAPHY , 1998 .

[18]  Alessandro Torricelli,et al.  Eight-channel time-resolved tissue oximeter for functional muscle studies , 2003, SPIE BiOS.