Evaluation of overhead lines current unbalance in meshed grids and its reduction

This paper describes new methodology in the current unbalance calculations in meshed grids. The meshed grids, mainly the transmission ones, consist of more parts connected together which are formed using different conductor types, phase sequence arrangements, tower constructions, and various number of lines on the same tower. Therefore several computational challenges arise in comparison with the widely discussed point-to-point configuration. The methodology divides the grid into a number of impedance matrices respecting all the self and mutual impedances among all conductors and all parallel lines. Another challenging issue for the lines impedance description is changing the number of shield wires along the line if the line is composed of several sections with different tower configurations. For the current unbalance calculation, shield wires must also be included in the algorithms, and matrices of various dimensions can be obtained. For the overall matrix description to be used, dimensions of all matrices in final equations must be equal, and therefore the virtual shield wires are created. To compare more conductor transposition cases with each other, the line loadings caused by voltage sources should be equal. This is necessary mainly in case of meshed grids where the supplying sources on different lines can have strong mutual couplings. This can be achieved by an appropriately designed optimization of the connected voltage sources.

[1]  M. Harry Hesse,et al.  Circulating Currents in Paralleled Untransposed Multicircuit Lines: I - Numerical Evaluations , 1966 .

[2]  A. Ametani,et al.  Study of super-bundle and low-reactance phasings on untransposed twin-circuit lines , 1990 .

[3]  A. Kalyuzhny,et al.  Analysis of Current Unbalance In Transmission Systems With Short Lines , 2007, IEEE Transactions on Power Delivery.

[4]  Zhiqian Bo,et al.  Unbalanced Circulating Current of Double-Circuit Transmission Lines , 2011, 2011 Asia-Pacific Power and Energy Engineering Conference.

[5]  Cai Zexiang,et al.  Research on circulating unbalance degree of double-circuit transmission line , 2014, IEEE PES Innovative Smart Grid Technologies, Europe.

[6]  Dahai You,et al.  Analysis of unbalanced current in a 220kV short double-circuit line , 2015, 2015 5th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT).

[7]  Takashi Hiyama,et al.  Protection of parallel multi-circuit transmission lines , 2003 .

[8]  M. Harry Hesse,et al.  Circulating Currents in Paralleled Untransposed Multicircuit Lines: II - Methods for Estimating Current Unbalance , 1966 .

[9]  Shuang Song,et al.  Analyzation of current characteristics on untransposed double-circuit lines , 2011, 2011 International Conference on Advanced Power System Automation and Protection.

[10]  J. R. Carson Wave propagation in overhead wires with ground return , 1926 .

[11]  D. E. Hedman,et al.  345-kV Line 60-Hz Ground Wire Losses , 1968 .

[12]  Yubo Yuan,et al.  Method for estimating unbalanced currents in untransposed double-circuit lines on the same tower , 2015 .

[13]  A. J. F. Keri,et al.  The Open Loop Scheme: An Effective Method of Ground Wire Loss Reduction , 1984, IEEE Transactions on Power Apparatus and Systems.

[14]  B. L. Metcalf Transmission and distribution of electricity to mines , 1944 .

[15]  Braham Ferreira,et al.  Utilizing Distributed Power Flow Controller (DPFC) for power oscillation damping , 2009, 2009 IEEE Power & Energy Society General Meeting.

[16]  Yufei Wang,et al.  Method to measure the unbalance of the multiple-circuit transmission lines on the same tower and its applications , 2016 .

[17]  Liu Mingbo Asymmetric issues caused by un-transposed transmission lines and its solution , 2010 .

[18]  Ahmad Abuelrub,et al.  New configuration constraints to reduce unbalance in hexagonal double-circuit transmission lines , 2015, 2015 North American Power Symposium (NAPS).

[19]  Lu Sun,et al.  Research on a new method to measure unbalance of multiple-circuit transmission lines on the same tower considering the impact of ground wire , 2015, 2015 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices (ASEMD).

[20]  Duan Xianzhong UNBALANCE ISSUE CAUSED BY UN-TRANSPOSED TRANSMISSION LINES AND ITS SOLUTION , 2004 .

[21]  Li Xiaohua,et al.  Analysis and Countermeasures for the Unbalance Problem of Multi-parallel Line on the Same Tower , 2010 .

[22]  Yang Xiu,et al.  Computation of unbalance factors for six-circuit transmission line on the same tower , 2011, 2011 IEEE Power Engineering and Automation Conference.

[23]  Wen Xishan Calculation and Analysis of Unbalanced Currents in Ningxia Northern 220 kV Power Gird , 2010 .

[24]  A.J.F. Keri,et al.  Shield wire loss reduction for double circuit transmission lines , 1988 .

[25]  M. Harry Hesse,et al.  EHV Double-Circuit Untransposed Transmission Line-Analysis and Tests , 1971 .

[26]  Braham Ferreira,et al.  Utilize Distributed Power Flow Controller (DPFC) to compensate unbalanced 3-phase currents in transmissions systems , 2009, 2009 International Conference on Electric Power and Energy Conversion Systems, (EPECS).

[27]  Michal Pokorny Analysis of Unbalance Due to Asymmetrical Loads , 2005 .

[28]  Bin Li,et al.  Circulating Unbalanced Currents of EHV/UHV Untransposed Double-Circuit Lines and Their Influence on Pilot Protection , 2014, IEEE Transactions on Power Delivery.