Fully automatic rhythm analysis during chest compression pauses.

AIM Chest compression artefacts impede a reliable rhythm analysis during cardiopulmonary resuscitation (CPR). These artefacts are not present during ventilations in 30:2 CPR. The aim of this study is to prove that a fully automatic method for rhythm analysis during ventilation pauses in 30:2 CPR is reliable an accurate. METHODS For this study 1414min of 30:2 CPR from 135 out-of-hospital cardiac arrest cases were analysed. The data contained 1942 pauses in compressions longer than 3.5s. An automatic pause detector identified the pauses using the transthoracic impedance, and a shock advice algorithm (SAA) diagnosed the rhythm during the detected pauses. The SAA analysed 3-s of the ECG during each pause for an accurate shock/no-shock decision. RESULTS The sensitivity and PPV of the pause detector were 93.5% and 97.3%, respectively. The sensitivity and specificity of the SAA in the detected pauses were 93.8% (90% low CI, 90.0%) and 95.9% (90% low CI, 94.7%), respectively. Using the method, shocks would have been advanced in 97% of occasions. For patients in nonshockable rhythms, rhythm reassessment pauses would be avoided in 95.2% (95% CI, 91.6-98.8) of occasions, thus increasing the overall chest compression fraction (CCF). CONCLUSION An automatic method could be used to safely analyse the rhythm during ventilation pauses. This would contribute to an early detection of refibrillation, and to increase CCF in patients with nonshockable rhythms.

[1]  U. Irusta,et al.  A Reliable Method for Rhythm Analysis during Cardiopulmonary Resuscitation , 2014, BioMed research international.

[2]  Jesus Ruiz,et al.  Rhythm Analysis during Cardiopulmonary Resuscitation: Past, Present, and Future , 2014, BioMed research international.

[3]  Judy Powell,et al.  The impact of increased chest compression fraction on return of spontaneous circulation for out-of-hospital cardiac arrest patients not in ventricular fibrillation. , 2011, Resuscitation.

[4]  R. Coronel,et al.  Ventricular fibrillation hampers the restoration of creatine-phosphate levels during simulated cardiopulmonary resuscitations. , 2012, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[5]  Søren Højsgaard,et al.  The R Package geepack for Generalized Estimating Equations , 2005 .

[6]  Judy Powell,et al.  Perishock Pause: An Independent Predictor of Survival From Out-of-Hospital Shockable Cardiac Arrest , 2011, Circulation.

[7]  Robert A. Berg,et al.  Adverse Hemodynamic Effects of Interrupting Chest Compressions for Rescue Breathing During Cardiopulmonary Resuscitation for Ventricular Fibrillation Cardiac Arrest , 2001, Circulation.

[8]  Yongqin Li,et al.  Identifying potentially shockable rhythms without interrupting cardiopulmonary resuscitation* , 2008, Critical care medicine.

[9]  L. Wik,et al.  Transthoracic impedance used to evaluate performance of cardiopulmonary resuscitation during out of hospital cardiac arrest. , 2008, Resuscitation.

[10]  R. Koster,et al.  Duration of Ventilations During Cardiopulmonary Resuscitation by Lay Rescuers and First Responders: Relationship Between Delivering Chest Compressions and Outcomes , 2013, Circulation.

[11]  Jo Kramer-Johansen,et al.  Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: a prospective interventional study. , 2006, Resuscitation.

[12]  T. Eftestøl,et al.  Suppression of the cardiopulmonary resuscitation artefacts using the instantaneous chest compression rate extracted from the thoracic impedance. , 2012, Resuscitation.

[13]  Irena Jekova,et al.  Shock advisory system with minimal delay triggering after end of chest compressions: accuracy and gained hands-off time. , 2011, Resuscitation.

[14]  U. Ayala,et al.  Automatic detection of chest compression pauses using the transthoracic impedance signal , 2012, 2012 Computing in Cardiology.

[15]  B. Abella,et al.  Uniform reporting of measured quality of cardiopulmonary resuscitation (CPR). , 2007, Resuscitation.

[16]  T. Eftestøl,et al.  Reliable extraction of the circulation component in the thoracic impedance measured by defibrillation pads. , 2013, Resuscitation.

[17]  Gavin D Perkins,et al.  European Resuscitation Council Guidelines for Resuscitation 2010 Section 4. Adult advanced life support. , 2010, Resuscitation.

[18]  Kyuseok Kim,et al.  Is there any room for shortening hands-off time further when using an AED? , 2009, Resuscitation.

[19]  B. Abella,et al.  Optimal loop duration during the provision of in-hospital advanced life support (ALS) to patients with an initial non-shockable rhythm. , 2014, Resuscitation.

[20]  L. Morrison,et al.  Compressions during defibrillator charging shortens shock pause duration and improves chest compression fraction during shockable out of hospital cardiac arrest. , 2014, Resuscitation.

[21]  David E. Snyder,et al.  Wide variation in cardiopulmonary resuscitation interruption intervals among commercially available automated external defibrillators may affect survival despite high defibrillation efficacy , 2004, Critical care medicine.

[22]  D. Atkins,et al.  Sensitivity and specificity of an automated external defibrillator algorithm designed for pediatric patients. , 2008, Resuscitation.

[23]  Harald Eikeland,et al.  The chain of survival. , 2006, Resuscitation.

[24]  Irena Jekova,et al.  Shock Advisory System for Heart Rhythm Analysis During Cardiopulmonary Resuscitation Using a Single ECG Input of Automated External Defibrillators , 2010, Annals of Biomedical Engineering.

[25]  Sofía Ruiz de Gauna,et al.  A high-temporal resolution algorithm to discriminate shockable from nonshockable rhythms in adults and children. , 2012, Resuscitation.

[26]  Jo Kramer-Johansen,et al.  Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest. , 2006, Resuscitation.

[27]  Mary Ann Peberdy,et al.  Part 8: Advanced life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations. , 2010, Circulation.

[28]  Yongqin Li,et al.  Amplitude spectrum area to guide resuscitation-a retrospective analysis during out-of-hospital cardiopulmonary resuscitation in 609 patients with ventricular fibrillation cardiac arrest. , 2013, Resuscitation.

[29]  T. Eftestøl,et al.  Direct evaluation of the effect of filtering the chest compression artifacts on the uninterrupted cardiopulmonary resuscitation time. , 2013, American Journal of Emergency Medicine.

[30]  Maaret Castrén,et al.  European Resuscitation Council Guidelines for Resuscitation 2010 Section 2. Adult basic life support and use of automated external defibrillators , 2010, Resuscitation.

[31]  Anna Engeln Time in Recurrent Ventricular Fibrillation and Survival after Out-of-hospital Cardiac Arrest , 2011 .

[32]  Richard E. Kerber,et al.  Automatic External Defibrillators for Public Access Defibrillation: Recommendations for Specifying and Reporting Arrhythmia Analysis Algorithm Performance, Incorporating New Waveforms, and Enhancing Safety , 1997, Biomedical instrumentation & technology.

[33]  A. Hadgu,et al.  A GEE approach to estimating sensitivity and specificity and coverage properties of the confidence intervals , 2001, Statistics in medicine.

[34]  Martin Botha,et al.  Part 5: Adult basic life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations. , 2010, Circulation.

[35]  David D. Salcido,et al.  The Effect of the Preshock Pause on Coronary Perfusion Pressure Decay and Rescue Shock Outcome in Porcine Ventricular Fibrillation , 2009, Prehospital emergency care : official journal of the National Association of EMS Physicians and the National Association of State EMS Directors.

[36]  P. Steen,et al.  Effects of Interrupting Precordial Compressions on the Calculated Probability of Defibrillation Success During Out-of-Hospital Cardiac Arrest , 2002, Circulation.

[37]  R. Migliani,et al.  DEFI 2005: A Randomized Controlled Trial of the Effect of Automated External Defibrillator Cardiopulmonary Resuscitation Protocol on Outcome From Out-of-Hospital Cardiac Arrest , 2010, Circulation.

[38]  S. O. Aase,et al.  Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECG. , 2004, Resuscitation.

[39]  E. Aramendi,et al.  Automatic detection of chest compressions for the assessment of CPR-quality parameters. , 2014, Resuscitation.

[40]  Trygve Eftestøl,et al.  Impedance-Based Ventilation Detection During Cardiopulmonary Resuscitation , 2007, IEEE Transactions on Biomedical Engineering.

[41]  Tobias Werther,et al.  Strong corruption of electrocardiograms caused by cardiopulmonary resuscitation reduces efficiency of two-channel methods for removing motion artefacts in non-shockable rhythms. , 2009, Resuscitation.

[42]  Cpr , 2005, Key Topics In Anaesthesia.

[43]  T. Eftestøl,et al.  Feasibility of automated rhythm assessment in chest compression pauses during cardiopulmonary resuscitation. , 2013, Resuscitation.