Optical-Clock-Based Time Scale.

A time scale is a procedure for accurately and continuously marking the passage of time. It is exemplified by Coordinated Universal Time (UTC) and provides the backbone for critical navigation tools such as the Global Positioning System. Present time scales employ microwave atomic clocks, whose attributes can be combined and averaged in a manner such that the composite is more stable, accurate, and reliable than the output of any individual clock. Over the past decade, clocks operating at optical frequencies have been introduced that are orders of magnitude more stable than any microwave clock. However, in spite of their great potential, these optical clocks cannot be operated continuously, which makes their use in a time scale problematic. We report the development of a hybrid microwave-optical time scale, which only requires the optical clock to run intermittently while relying upon the ensemble of microwave clocks to serve as the flywheel oscillator. The benefit of using a clock ensemble as the flywheel oscillator instead of a single clock can be understood by the Dick-effect limit. This time scale demonstrates for the first time subnanosecond accuracy over a few months, attaining a fractional frequency stability of 1.45 × 10-16 at 30 days and reaching the 10-17 decade at 50 days, with respect to UTC. This time scale significantly improves the accuracy in timekeeping and could change the existing time-scale architectures.

[1]  Robert Jördens,et al.  Oscillator metrology with software defined radio. , 2016, The Review of scientific instruments.

[2]  Eva Bookjans,et al.  Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock , 2016, 1605.03878.

[3]  M. Pospelov,et al.  Hunting for topological dark matter with atomic clocks , 2013, Nature Physics.

[4]  Fritz Riehle,et al.  Optical clock networks , 2017, Nature Photonics.

[5]  A. Aurisano,et al.  Precision measurement of the speed of propagation of neutrinos using the MINOS detectors , 2015, 1507.04328.

[6]  Jian Yao,et al.  An Improvement of Rinex-Shift Algorithm for Continuous GPS Carrier-Phase Time Transfer (Final Version).pdf , 2014 .

[7]  C Sanner,et al.  Single-Ion Atomic Clock with 3×10(-18) Systematic Uncertainty. , 2016, Physical review letters.

[8]  Judah Levine,et al.  Progress on optical-clock-based time scale at NIST: Simulations and preliminary real-data analysis , 2018 .

[9]  Przemyslaw Krehlik,et al.  Fiber-Optic Time Transfer for UTC-Traceable Synchronization for Telecom Networks , 2017, IEEE Communications Standards.

[10]  Albin Czubla,et al.  Use of software-defined radio receivers in two-way satellite time and frequency transfers for UTC computation , 2018, Metrologia.

[11]  W. Riley,et al.  Handbook of frequency stability analysis , 2008 .

[12]  Judah Levine,et al.  Invited review article: The statistical modeling of atomic clocks and the design of time scales. , 2012, The Review of scientific instruments.

[13]  S. Romisch,et al.  Towards Adoption of an Optical Second: Verifying Optical Clocks at the SI Limit , 2018, 1811.05885.

[15]  Esther Baumann,et al.  Optical two-way time and frequency transfer over free space , 2013 .

[16]  S. Falke,et al.  Ultrastable laser with average fractional frequency drift rate below 5 × 10⁻¹⁹/s. , 2014, Optics letters.

[17]  Judah Levine,et al.  A detailed comparison of two continuous GPS carrier-phase time transfer techniques , 2015, 2015 Joint Conference of the IEEE International Frequency Control Symposium & the European Frequency and Time Forum.

[18]  S. Weyers,et al.  Realization of a timescale with an accurate optical lattice clock , 2015, 1511.03888.

[19]  Eric A. Burt,et al.  Using the Deep Space Atomic Clock for Navigation and Science , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[20]  T. Hänsch,et al.  A 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place , 2012, Science.

[21]  Felix Perosanz,et al.  1 × 10−16 frequency transfer by GPS PPP with integer ambiguity resolution , 2015 .

[22]  Y. Hanado,et al.  Months-long real-time generation of a time scale based on an optical clock , 2018, Scientific Reports.

[23]  W. Marsden I and J , 2012 .

[24]  T. Gotoh,et al.  Carrier-phase-based two-way satellite time and frequency transfer , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[25]  Judah Levine,et al.  Incorporating an Optical Clock Into a Time Scale , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[26]  David A. Howe,et al.  Handbook of Frequency Stability Analysis | NIST , 2008 .

[27]  Gianna Panfilo,et al.  Timescales at the BIPM , 2011 .

[28]  A. Bjerhammar,et al.  On a relativistic geodesy , 1985 .

[29]  I.A. Getting,et al.  Perspective/navigation-The Global Positioning System , 1993, IEEE Spectrum.

[30]  S. Diddams,et al.  Octave-spanning Ti:sapphire laser with a repetition rate >1 ghz for optical frequency measurements and comparisons. , 2006, Optics letters.

[31]  M. Schioppo,et al.  Ultrastable optical clock with two cold-atom ensembles , 2016, Nature Photonics.

[32]  Patrizia Tavella,et al.  The 50th Anniversary of the Atomic Second , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[33]  Thomas B. Swanson,et al.  Evaluation of Long Term Performance of Continuously Running Atomic Fountains , 2014 .

[34]  E. F. Arias,et al.  Atomic time-keeping from 1955 to the present , 2005 .

[35]  S. Romisch,et al.  Towards the optical second: verifying optical clocks at the SI limit , 2019, Optica.

[36]  Thomas E. Parker,et al.  JY1 time scale: a new Kalman-filter time scale designed at NIST , 2017 .

[37]  Patrick Gill,et al.  The CIPM list of recommended frequency standard values: guidelines and procedures , 2018 .

[38]  Lei Chen,et al.  A sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity , 2011, Nature Photonics.

[39]  A.H. Haddad,et al.  Applied optimal estimation , 1976, Proceedings of the IEEE.

[40]  Xi Fang,et al.  3. Full Four-channel 6.3-gb/s 60-ghz Cmos Transceiver with Low-power Analog and Digital Baseband Circuitry 7. Smart Grid — the New and Improved Power Grid: a Survey , 2022 .

[41]  George Neville-Neil,et al.  Accurate, Traceable, and Verifiable Time Synchronization for World Financial Markets. , 2016, Journal of research of the National Institute of Standards and Technology.

[42]  R. Vessot The atomic hydrogen maser oscillator , 2005 .

[43]  Leonard S. Cutler,et al.  Fifty years of commercial caesium clocks , 2005 .

[44]  Elliott D. Kaplan Understanding GPS : principles and applications , 1996 .

[45]  Wei Zhang,et al.  An optical lattice clock with accuracy and stability at the 10−18 level , 2013, Nature.

[46]  Stefano Bregni,et al.  Synchronization of Digital Telecommunications Networks , 2002 .

[47]  André Clairon,et al.  The Dick effect for an optical frequency standard , 2003 .

[48]  Dirk Piester,et al.  Generation of UTC(PTB) as a fountain-clock based time scale , 2012 .

[49]  D. Wineland,et al.  Frequency comparison of two high-accuracy Al+ optical clocks. , 2009, Physical review letters.

[50]  Marco Pizzocaro,et al.  An Atomic Clock with 10–¹⁸ Instability , 2013 .

[51]  A. Ludlow,et al.  An Atomic Clock with 10–18 Instability , 2013, Science.