Evaluation of Biological Properties of Electron Beam Melted Ti6Al4V Implant with Biomimetic Coating In Vitro and In Vivo

Background High strength porous titanium implants are widely used for the reconstruction of craniofacial defects because of their similar mechanical properties to those of bone. The recent introduction of electron beam melting (EBM) technique allows a direct digitally enabled fabrication of patient specific porous titanium implants, whereas both their in vitro and in vivo biological performance need further investigation. Methods In the present study, we fabricated porous Ti6Al4V implants with controlled porous structure by EBM process, analyzed their mechanical properties, and conducted the surface modification with biomimetic approach. The bioactivities of EBM porous titanium in vitro and in vivo were evaluated between implants with and without biomimetic apatite coating. Results The physical property of the porous implants, containing the compressive strength being 163 - 286 MPa and the Young’s modulus being 14.5–38.5 GPa, is similar to cortical bone. The in vitro culture of osteoblasts on the porous Ti6Al4V implants has shown a favorable circumstance for cell attachment and proliferation as well as cell morphology and spreading, which were comparable with the implants coating with bone-like apatite. In vivo, histological analysis has obtained a rapid ingrowth of bone tissue from calvarial margins toward the center of bone defect in 12 weeks. We observed similar increasing rate of bone ingrowth and percentage of bone formation within coated and uncoated implants, all of which achieved a successful bridging of the defect in 12 weeks after the implantation. Conclusions This study demonstrated that the EBM porous Ti6Al4V implant not only reduced the stress-shielding but also exerted appropriate osteoconductive properties, as well as the apatite coated group. The results opened up the possibility of using purely porous titanium alloy scaffolds to reconstruct specific bone defects in the maxillofacial and orthopedic fields.

[1]  R. Singer,et al.  Cellular Ti-6Al-4V structures with interconnected macro porosity for bone implants fabricated by selective electron beam melting. , 2008, Acta biomaterialia.

[2]  S. Bhaduri,et al.  Osteoblast proliferation on neat and apatite-like calcium phosphate-coated titanium foam scaffolds , 2007 .

[3]  S. Hansson,et al.  The relation between surface roughness and interfacial shear strength for bone-anchored implants. A mathematical model. , 1999, Journal of biomechanics.

[4]  P. Layrolle,et al.  Osteointegration of biomimetic apatite coating applied onto dense and porous metal implants in femurs of goats. , 2003, Journal of biomedical materials research. Part B, Applied biomaterials.

[5]  B Vamsi Krishna,et al.  Low stiffness porous Ti structures for load-bearing implants. , 2007, Acta biomaterialia.

[6]  B. Meenan,et al.  Biological responses to hydroxyapatite surfaces deposited via a co-incident microblasting technique. , 2010, Biomaterials.

[7]  M. Stevens,et al.  The role of intracellular calcium phosphate in osteoblast-mediated bone apatite formation , 2012, Proceedings of the National Academy of Sciences.

[8]  Wenguang Zhang,et al.  Fabrication and characterization of porous Ti6Al4V parts for biomedical applications using electron beam melting process , 2009 .

[9]  Anders Snis,et al.  Electron beam-melted, free-form-fabricated titanium alloy implants: Material surface characterization and early bone response in rabbits. , 2008, Journal of biomedical materials research. Part B, Applied biomaterials.

[10]  P. Griss,et al.  Implant fixation by bone ingrowth. , 1999, The Journal of arthroplasty.

[11]  A. C. Guastaldi,et al.  Biomimetic apatite formation on Ultra-High Molecular Weight Polyethylene (UHMWPE) using modified biomimetic solution , 2009, Journal of materials science. Materials in medicine.

[12]  Maxence Bigerelle,et al.  The relative influence of the topography and chemistry of TiAl6V4 surfaces on osteoblastic cell behaviour. , 2000, Biomaterials.

[13]  Y. Sugita,et al.  Effects of pico-to-nanometer-thin TiO2 coating on the biological properties of microroughened titanium. , 2011, Biomaterials.

[14]  A. Uchida,et al.  Growth of bone marrow cells on porous ceramics in vitro. , 1987, Journal of biomedical materials research.

[15]  Emeka Nkenke,et al.  In vivo performance of selective electron beam-melted Ti-6Al-4V structures. , 2010, Journal of biomedical materials research. Part A.

[16]  Lingzhou Zhao,et al.  The influence of hierarchical hybrid micro/nano-textured titanium surface with titania nanotubes on osteoblast functions. , 2010, Biomaterials.

[17]  M. Neo,et al.  A novel synthetic material for spinal fusion: a prospective clinical trial of porous bioactive titanium metal for lumbar interbody fusion , 2011, European Spine Journal.

[18]  Emeka Nkenke,et al.  Effects of topographical surface modifications of electron beam melted Ti-6Al-4V titanium on human fetal osteoblasts. , 2008, Journal of biomedical materials research. Part A.

[19]  Shivakumar Raman,et al.  Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM). , 2010, Journal of the mechanical behavior of biomedical materials.

[20]  M. von Walter,et al.  Structural, mechanical and in vitro characterization of individually structured Ti-6Al-4V produced by direct laser forming. , 2006, Biomaterials.

[21]  G. Daculsi,et al.  Osteointegration of femoral stem prostheses with a bilayered calcium phosphate coating. , 2006, Biomaterials.

[22]  Clemens A van Blitterswijk,et al.  Bone ingrowth in porous titanium implants produced by 3D fiber deposition. , 2007, Biomaterials.

[23]  P. Tengvall,et al.  Bone formation after 4 weeks around blood-plasma-modified titanium implants with varying surface topographies: an in vivo study. , 2003, Biomaterials.

[24]  H. M. Kim,et al.  Bonding strength of bonelike apatite layer to Ti metal substrate. , 1997, Journal of biomedical materials research.

[25]  Abhay Pandit,et al.  Fabrication methods of porous metals for use in orthopaedic applications. , 2006, Biomaterials.

[26]  Dietmar W Hutmacher,et al.  Scaffold-based tissue engineering: rationale for computer-aided design and solid free-form fabrication systems. , 2004, Trends in biotechnology.

[27]  F. Müller,et al.  Osteoblast response to biomimetically altered titanium surfaces. , 2008, Acta biomaterialia.

[28]  C. Leroux,et al.  Bone growth in rapid prototyped porous titanium implants. , 2008, Journal of biomedical materials research. Part A.

[29]  F. Müller,et al.  Biomimetic apatite formation on chemically treated titanium. , 2004, Biomaterials.

[30]  Pierre Layrolle,et al.  Rapid prototyped porous titanium coated with calcium phosphate as a scaffold for bone tissue engineering. , 2008, Biomaterials.

[31]  Tadashi Kokubo,et al.  How useful is SBF in predicting in vivo bone bioactivity? , 2006, Biomaterials.

[32]  A. Milev,et al.  Morphology of sol-gel derived nano-coated coralline hydroxyapatite. , 2004, Biomaterials.

[33]  C. V. van Blitterswijk,et al.  Biological performance in goats of a porous titanium alloy-biphasic calcium phosphate composite. , 2007, Biomaterials.

[34]  S. Hollister,et al.  Optimal design and fabrication of scaffolds to mimic tissue properties and satisfy biological constraints. , 2002, Biomaterials.

[35]  Yong Han,et al.  Initial osteoblast functions on Ti-5Zr-3Sn-5Mo-15Nb titanium alloy surfaces modified by microarc oxidation. , 2009, Journal of biomedical materials research. Part A.

[36]  R. Borojevic,et al.  Effect of three distinct treatments of titanium surface on osteoblast attachment, proliferation, and differentiation. , 2005, Clinical oral implants research.

[37]  C. V. van Blitterswijk,et al.  Porous Ti6Al4V scaffold directly fabricating by rapid prototyping: preparation and in vitro experiment. , 2006, Biomaterials.

[38]  Tadashi Kokubo,et al.  Mechanical properties and osteoconductivity of porous bioactive titanium. , 2005, Biomaterials.

[39]  H. Hahn,et al.  Preliminary evaluation of porous metal surfaced titanium for orthopedic implants. , 1970, Journal of biomedical materials research.

[40]  K. Leong,et al.  Solid freeform fabrication of three-dimensional scaffolds for engineering replacement tissues and organs. , 2003, Biomaterials.

[41]  K. Peng,et al.  Electrophoretic deposition of porous hydroxyapatite scaffold. , 2003, Biomaterials.

[42]  Jai-Young Koak,et al.  Improved biological performance of Ti implants due to surface modification by micro-arc oxidation. , 2004, Biomaterials.

[43]  R M Pilliar,et al.  Porous-surfaced metallic implants for orthopedic applications. , 1987, Journal of biomedical materials research.

[44]  Maxence Bigerelle,et al.  Qualitative and quantitative study of human osteoblast adhesion on materials with various surface roughnesses. , 2000, Journal of biomedical materials research.

[45]  J. Jurvelin,et al.  Bone density at the proximal femur after total hip arthroplasty. , 1998, Clinical orthopaedics and related research.

[46]  H. M. Kim,et al.  The effect of heat treatment on bone-bonding ability of alkali-treated titanium. , 1999, Biomaterials.