Online monitoring of transformer winding axial displacement and its extent using scattering parameters and k-nearest neighbour method

The online monitoring of the transformer winding using scattering parameters fingerprint is presented. As a test object, a simplified model of transformer is used. The winding axial displacement is modelled on this test object. The scattering parameters of the test object are calculated using the high-frequency simulation software and measured using a network analyser. Two indices are defined based on the magnitude and phase of scattering parameters for the detection of the axial displacement. A new algorithm for the estimation of the axial displacement extent is presented using the proposed indices and high-frequency modelling of the transformer. To detect this mechanical defect and its extent, the k-nearest neighbour (k-NN) regression is suggested.

[1]  T. Leibfried,et al.  Monitoring of power transformers using the transfer function method , 1999 .

[2]  Bhavani M. Thuraisingham,et al.  Face Recognition Using Multiple Classifiers , 2006, 2006 18th IEEE International Conference on Tools with Artificial Intelligence (ICTAI'06).

[3]  T. Leibfried,et al.  On-line monitoring of transformers by means of the transfer function method , 1994, Proceedings of 1994 IEEE International Symposium on Electrical Insulation.

[4]  Ij Craddock,et al.  Locating partial discharges using UHF measurements: a study of signal propagation using the finite difference time domain method , 2005 .

[5]  K. Feser,et al.  Procedures for detecting winding displacements in power transformers by the transfer function method , 2004, IEEE Transactions on Power Delivery.

[6]  L. N. Kanal,et al.  Handbook of Statistics, Vol. 2. Classification, Pattern Recognition and Reduction of Dimensionality. , 1985 .

[7]  Caixin Sun,et al.  Study on the recognition of transformer winding deformation by using wavelet transform in the LVI method , 2002, Proceedings. International Conference on Power System Technology.

[8]  T. Leibfried,et al.  Off-line- and on-line-monitoring of power transformers using the transfer function method , 1996, Conference Record of the 1996 IEEE International Symposium on Electrical Insulation.

[9]  James M. Keller,et al.  A fuzzy K-nearest neighbor algorithm , 1985, IEEE Transactions on Systems, Man, and Cybernetics.

[10]  K. Feser,et al.  Transfer Function Method to Diagnose Axial Displacement and Radial Deformation of Transformer Winding , 2002, IEEE Power Engineering Review.

[11]  M.D. Judd,et al.  Partial discharge monitoring of power transformers using UHF sensors. Part I: sensors and signal interpretation , 2005, IEEE Electrical Insulation Magazine.

[12]  Thierry Denoeux,et al.  A k-nearest neighbor classification rule based on Dempster-Shafer theory , 1995, IEEE Trans. Syst. Man Cybern..

[13]  Sahibsingh A. Dudani The Distance-Weighted k-Nearest-Neighbor Rule , 1976, IEEE Transactions on Systems, Man, and Cybernetics.

[14]  B. K. Panigrahi,et al.  Optimal feature selection for classification of power quality disturbances using wavelet packet-based fuzzy k-nearest neighbour algorithm , 2009 .

[15]  Qing-Cai Chen,et al.  GA-based feature subset clustering for combination of multiple nearest neighbors classifiers , 2005, 2005 International Conference on Machine Learning and Cybernetics.

[16]  A. S. Morched,et al.  Analysis of internal winding stresses in EHV generator step-up transformer failures , 1996 .

[17]  Peter E. Hart,et al.  Nearest neighbor pattern classification , 1967, IEEE Trans. Inf. Theory.

[18]  Anil K. Jain,et al.  39 Dimensionality and sample size considerations in pattern recognition practice , 1982, Classification, Pattern Recognition and Reduction of Dimensionality.

[19]  D. K. Xu,et al.  On-line monitoring of winding deformation of power transformer , 2001, Proceedings of 2001 International Symposium on Electrical Insulating Materials (ISEIM 2001). 2001 Asian Conference on Electrical Insulating Diagnosis (ACEID 2001). 33rd Symposium on Electrical and Ele.

[20]  R. Kaul,et al.  Microwave engineering , 1989, IEEE Potentials.

[21]  Gevork B. Gharehpetian,et al.  Determination of axial displacement extent based on transformer winding transfer function estimation using vector-fitting method , 2008 .

[22]  Hongwei Zhu,et al.  An adaptive fuzzy evidential nearest neighbor formulation for classifying remote sensing images , 2005, IEEE Transactions on Geoscience and Remote Sensing.

[23]  Qing-Cai Chen,et al.  Combination of Multiple K-NNCS by Fuzzy Integral , 2006, 2006 International Conference on Machine Learning and Cybernetics.

[24]  Pradeep M. Nirgude,et al.  Application of numerical evaluation techniques for interpreting frequency response measurements in power transformers , 2008 .