An Integrated System for Superharmonic Contrast-Enhanced Ultrasound Imaging: Design and Intravascular Phantom Imaging Study

Objective: Superharmonic contrast-enhanced ultrasound imaging, also called acoustic angiography, has previously been used for the imaging of microvasculature. This approach excites microbubble contrast agents near their resonance frequency and receives echoes at nonoverlapping superharmonic bandwidths. No integrated system currently exists could fully support this application. To fulfill this need, an integrated dual-channel transmit/receive system for superharmonic imaging was designed, built, and characterized experimentally. Method: The system was uniquely designed for superharmonic imaging and high-resolution B-mode imaging. A complete ultrasound system including a pulse generator, a data acquisition unit, and a signal processing unit were integrated into a single package. The system was controlled by a field-programmable gate array, on which multiple user-defined modes were implemented. A 6-, 35-MHz dual-frequency dual-element intravascular ultrasound transducer was designed and used for imaging. Result: The system successfully obtained high-resolution B-mode images of coronary artery ex vivo with 45-dB dynamic range. The system was capable of acquiring in vitro superharmonic images of a vasa vasorum mimicking phantom with 30-dB contrast. It could detect a contrast agent filled tissue mimicking tube of 200 μm diameter. Conclusion: For the first time, high-resolution B-mode images and superharmonic images were obtained in an intravascular phantom, made possible by the dedicated integrated system proposed. The system greatly reduced the cost and complexity of the superharmonic imaging intended for preclinical study. Significant: The system showed promise for high-contrast intravascular microvascular imaging, which may have significant importance in assessment of the vasa vasorum associated with atherosclerotic plaques.

[1]  M. Marcus,et al.  Role of vasa vasorum in nourishment of the aortic wall. , 1981, The American journal of physiology.

[2]  A. Bouakaz,et al.  The effects of bubble size on nonlinear scattering from microbubbles , 2003, IEEE Symposium on Ultrasonics, 2003.

[3]  F. Duck Nonlinear acoustics in diagnostic ultrasound. , 2002, Ultrasound in medicine & biology.

[4]  F. T. ten Cate,et al.  Super harmonic imaging: a new imaging technique for improved contrast detection. , 2002, Ultrasound in medicine & biology.

[5]  S. Emelianov,et al.  Intravascular photoacoustic imaging using an IVUS imaging catheter , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  Hojong Choi,et al.  Power MOSFET–Diode–Based Limiter for High-Frequency Ultrasound Systems , 2014, Ultrasonic imaging.

[7]  Qifa Zhou,et al.  An open system for intravascular ultrasound imaging , 2012, 2012 IEEE International Ultrasonics Symposium.

[8]  Charles T. Lancée,et al.  Higher harmonics of vibrating gas-filled microspheres. Part one: simulations , 1994 .

[9]  A J Tajik,et al.  Intravascular ultrasound imaging: in vitro validation and pathologic correlation. , 1990, Journal of the American College of Cardiology.

[10]  N. Caplice,et al.  Plaque neovascularization and antiangiogenic therapy for atherosclerosis. , 2007, Journal of the American College of Cardiology.

[11]  Wouter Peeters,et al.  Composition of Carotid Atherosclerotic Plaque Is Associated With Cardiovascular Outcome: A Prognostic Study , 2010, Circulation.

[12]  E. Boerwinkle,et al.  From vulnerable plaque to vulnerable patient: a call for new definitions and risk assessment strategies: Part I. , 2003, Circulation.

[13]  P. Burns,et al.  Pulse inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[14]  E L Ritman,et al.  Impact of coronary vasa vasorum functional structure on coronary vessel wall perfusion distribution. , 2003, American journal of physiology. Heart and circulatory physiology.

[15]  Jianguo Ma,et al.  An acoustic filter based on layered structure. , 2015, Applied physics letters.

[16]  Xiaoning Jiang,et al.  Design factors of intravascular dual frequency transducers for super-harmonic contrast imaging and acoustic angiography , 2015, Physics in medicine and biology.

[17]  Juan F Granada,et al.  Imaging of the vasa vasorum , 2008, Nature Clinical Practice Cardiovascular Medicine.

[18]  Paul A Dayton,et al.  Improving Sensitivity in Ultrasound Molecular Imaging by Tailoring Contrast Agent Size Distribution: In Vivo Studies , 2010, Molecular imaging.

[19]  P. Fitzgerald,et al.  Intravascular ultrasound: state of the art and future directions. , 1998, The American journal of cardiology.

[20]  F Forsberg,et al.  Ultrasonic characterization of the nonlinear properties of contrast microbubbles. , 2000, Ultrasound in medicine & biology.

[21]  Flordeliza S. Villanueva,et al.  Radial modulation contrast imaging using a 20-mhz single-element intravascular ultrasound catheter , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[22]  Juan J. Badimon,et al.  Plaque Neovascularization Is Increased in Ruptured Atherosclerotic Lesions of Human Aorta: Implications for Plaque Vulnerability , 2004, Circulation.

[23]  Geoffrey D Rubin,et al.  Atherosclerotic Vascular Disease Conference: Writing Group IV: imaging. , 2004, Circulation.

[24]  Qifa Zhou,et al.  Integrated IVUS-OCT for real-time imaging of coronary atherosclerosis. , 2014, JACC. Cardiovascular imaging.

[25]  Jianguo Ma,et al.  Anti-Matching Design for Wave Isolation in Dual Frequency Transducer for Intravascular Super-Harmonic Imaging , 2014 .

[26]  Jianguo Ma,et al.  A preliminary engineering design of intravascular dual-frequency transducers for contrast-enhanced acoustic angiography and molecular imaging , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[27]  Nico de Jong,et al.  Nonlinear intravascular ultrasound contrast imaging. , 2006, Ultrasound in medicine & biology.

[28]  Paul A Dayton,et al.  High-resolution, high-contrast ultrasound imaging using a prototype dual-frequency transducer: In vitro and in vivo studies , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[29]  Marc Sirol,et al.  Neovascularization in Human Atherosclerosis , 2006, Circulation.

[30]  Qifa Zhou,et al.  Multi-frequency intravascular ultrasound (IVUS) imaging , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[31]  M. Lewandowski,et al.  High frequency coded imaging system with RF , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[32]  K. Ferrara,et al.  A new imaging strategy using wideband transient response of ultrasound contrast agents , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[33]  K. Kirk Shung,et al.  Harmonic distortion reduction technique of the power amplifier for very high frequency ultrasonic transducer applications , 2013, 2013 IEEE International Ultrasonics Symposium (IUS).

[34]  N. de Jong,et al.  P2A-3 High Frequency Attenuation and Size Distribution Measurements of Definity and Manipulated Definity Populations , 2006, 2006 IEEE Ultrasonics Symposium.

[35]  Qifa Zhou,et al.  Micromachined PIN-PMN-PT crystal composite transducer for high-frequency intravascular ultrasound (IVUS) imaging , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[36]  F. Stuart Foster,et al.  Dual-Frequency Piezoelectric Transducers for Contrast Enhanced Ultrasound Imaging , 2014, Sensors.

[37]  E. Madsen,et al.  Tissue mimicking materials for ultrasound phantoms. , 1978, Medical physics.

[38]  E. Tuzcu,et al.  Coronary Plaque Classification With Intravascular Ultrasound Radiofrequency Data Analysis , 2002, Circulation.

[39]  Ryan C. Gessner,et al.  Acoustic Angiography: A New Imaging Platform for High Resolution Mapping of Microvasculature and Tumor Assessment , 2013 .

[40]  Mark M. Kockx,et al.  Phagocytosis and Macrophage Activation Associated With Hemorrhagic Microvessels in Human Atherosclerosis , 2003, Arteriosclerosis, thrombosis, and vascular biology.

[41]  V. Fuster,et al.  Coronary plaque disruption. , 1995, Circulation.

[42]  Qifa Zhou,et al.  Contrast-enhanced intravascular ultrasound pulse sequences for bandwidth-limited transducers. , 2013, Ultrasound in medicine & biology.

[43]  F. Stuart Foster,et al.  Acoustic Angiography: A New Imaging Modality for Assessing Microvasculature Architecture , 2013, Int. J. Biomed. Imaging.

[44]  P. Tortoli,et al.  A programmable real-time system for development and test of new ultrasound investigation methods , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[45]  Qifa Zhou,et al.  A configurable dual-frequency transmit/receive system for acoustic angiography imaging , 2014, 2014 IEEE International Ultrasonics Symposium.

[46]  Paul A. Dayton,et al.  Acoustic characterization of contrast-to-tissue ratio and axial resolution for dual-frequency contrast-specific acoustic angiography imaging , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[47]  Nico de Jong,et al.  Subharmonic contrast intravascular ultrasound for vasa vasorum imaging. , 2007, Ultrasound in medicine & biology.

[48]  P. Stone,et al.  Circadian variation and triggers of onset of acute cardiovascular disease. , 1989, Circulation.

[49]  Paul A Dayton,et al.  Quantification of Microvascular Tortuosity during Tumor Evolution Using Acoustic Angiography. , 2015, Ultrasound in medicine & biology.

[50]  O. Olssón,et al.  Vertebral Angiography in the Diagnosis of Acoustic Nerve Tumours , 1953 .

[51]  Nico de Jong,et al.  Contrast Harmonic Intravascular Ultrasound: A Feasibility Study for Vasa Vasorum Imaging , 2006, Investigative radiology.

[52]  Mark Borden,et al.  Ultrasound microbubble contrast agents: fundamentals and application to gene and drug delivery. , 2007, Annual review of biomedical engineering.