Practical considerations in the use of polarized light microscopy in the analysis of the collagen network in articular cartilage

Polarized light microscopy is a traditional method for visualizing the collagen network architecture of articular cartilage. Articular cartilage repair and tissue engineering studies have raised new demands for techniques capable of quantitative characterization of the scar and repair tissues, including properties of the collagen network. Modern polarized light microscopy can be used to measure collagen fibril orientation, parallelism, and birefringence. New commercial instruments are computer controlled and the measurements are easy to perform. However, often the interpretation of results causes difficulties, even errors, because the theoretical aspects of the technique are demanding. The aim of this study was to describe the instrumentation and properties of a modern polarized light microscope, to point out some sources of error in the interpretation of the results, and to recall the theoretical background of the polarized light microscopy. Microsc. Res. Tech., 2008. © 2007 Wiley‐Liss, Inc.

[1]  Jukka S. Jurvelin,et al.  Structure-Function Relationships in Enzymatically Modified Articular Cartilage , 2003, Cells Tissues Organs.

[2]  T Lapveteläinen,et al.  Decreased birefringence of the superficial zone collagen network in the canine knee (stifle) articular cartilage after long distance running training, detected by quantitative polarised light microscopy. , 1996, Annals of the rheumatic diseases.

[3]  R. Azzam,et al.  Polarized light in optics and spectroscopy , 1990 .

[4]  Edward Collett,et al.  Polarized light. Fundamentals and applications , 1993 .

[5]  R M Aspden,et al.  Birefringence of articular cartilage and the distribution on collagen fibril orientations. , 1983, Connective tissue research.

[6]  Juha Töyräs,et al.  Spatial assessment of articular cartilage proteoglycans with Gd‐DTPA‐enhanced T1 imaging , 2002, Magnetic resonance in medicine.

[7]  R Mendelsohn,et al.  FTIR microscopic imaging of collagen and proteoglycan in bovine cartilage. , 2001, Biopolymers.

[8]  R. Oldenbourg,et al.  New polarized light microscope with precision universal compensator , 1995, Journal of microscopy.

[9]  D. Maurice The structure and transparency of the cornea , 1957, The Journal of physiology.

[10]  Y. Xia,et al.  Quantitative in situ correlation between microscopic MRI and polarized light microscopy studies of articular cartilage. , 2001, Osteoarthritis and cartilage.

[11]  L H Kidder,et al.  Imaging of collagen and proteoglycan in cartilage sections using Fourier transform infrared spectral imaging. , 2001, Arthritis and rheumatism.

[12]  Yang Xia,et al.  Imaging the physical and morphological properties of a multi‐zone young articular cartilage at microscopic resolution , 2003, Journal of magnetic resonance imaging : JMRI.

[13]  J. Arokoski,et al.  Electron microscopic stereological study of collagen fibrils in bovine articular cartilage: volume and surface densities are best obtained indirectly (from length densities and diameters) using isotropic uniform random sampling , 1999, Journal of anatomy.

[14]  J. Arokoski,et al.  Specimen preparation and quantification of collagen birefringence in unstained sections of articular cartilage using image analysis and polarizing light microscopy , 1997, The Histochemical Journal.

[15]  Y. Xia,et al.  Characteristics of topographical heterogeneity of articular cartilage over the joint surface of a humeral head. , 2002, Osteoarthritis and cartilage.

[16]  L. Módis Organization of the Extracellular Matrix: A Polarization Microscopic Approach , 1990 .

[17]  T. Wilson,et al.  Quantitative polarized light microscopy , 2003, Journal of microscopy.