Filtered Backprojection Reconstruction and Redundancy in Compton Camera Imaging

During the acquisition process with the Compton gamma-camera, integrals of the intensity distribution of the source on conical surfaces are measured. They represent the Compton projections of the intensity. The inversion of the Compton transform reposes on a particular Fourier-Slice theorem. This paper proposes a filtered backprojection algorithm for image reconstruction from planar Compton camera data. We show how different projections are related together and how they may be combined in the tomographical reconstruction step. Considering a simulated Compton imaging system, we conclude that the proposed method yields accurate reconstructed images for simple sources. An elongation of the source in the direction orthogonal to the camera may be observed and is to be related to the truncation of the projections induced by the finite extent of the device. This phenomenon was previously observed with other reconstruction methods, e.g., iterative maximum likelihood expectation maximization. The redundancy of the Compton transform is thus an important feature for the reduction of noise in Compton images, since the ideal assumptions of infinite width and observation time are never met in practice. We show that a selection operated on the set of data allows to partially get around projection truncation, at the expense of an enhancement of the noise in the images.

[1]  Rémy Prost,et al.  Analytical inversion of the Compton transform using the full set of available projections , 2009 .

[2]  Philip J. Bones,et al.  Towards direct reconstruction from a gamma camera based on Compton scattering , 1994, IEEE Trans. Medical Imaging.

[3]  Robert Andritschke,et al.  MEGAlib – The Medium Energy Gamma-ray Astronomy Library , 2006 .

[4]  J. M. Nightingale,et al.  A proposed γ camera , 1974, Nature.

[5]  T. Tomitani,et al.  An analytical image reconstruction algorithm to compensate for scattering angle broadening in Compton cameras. , 2003, Physics in medicine and biology.

[6]  Bruce Smith,et al.  Reconstruction methods and completeness conditions for two Compton data models. , 2005, Journal of the Optical Society of America. A, Optics, image science, and vision.

[7]  Taewoong Lee,et al.  A compact Compton camera using scintillators for the investigation of nuclear materials , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[8]  G T Gullberg,et al.  Application of spherical harmonics to image reconstruction for the Compton camera. , 1998, Physics in medicine and biology.

[9]  Sudhakar Chelikani,et al.  Optimizing Compton camera geometries. , 2004, Physics in medicine and biology.

[10]  M.-H. A. Huang,et al.  DETECTION AND IMAGING OF THE CRAB NEBULA WITH THE NUCLEAR COMPTON TELESCOPE , 2011, 1106.0323.

[11]  Bruce D. Smith Line-reconstruction from Compton cameras: data sets and a camera design , 2011 .

[12]  Jeffrey A. Fessler,et al.  Benefits of Position-Sensitive Detectors for Radioactive Source Detection , 2010, IEEE Transactions on Signal Processing.

[13]  L. Parra,et al.  Reconstruction of cone-beam projections from Compton scattered data , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[14]  Li Han,et al.  Statistical performance evaluation and comparison of a Compton medical imaging system and a collimated Anger camera for higher energy photon imaging , 2008, Physics in medicine and biology.

[15]  A. Zoglauer,et al.  A Tracking Compton-Scattering Imaging System for Hadron Therapy Monitoring , 2010, IEEE Transactions on Nuclear Science.