Induction machine fault diagnosis using an external radial flux sensor

This paper presents a method for detecting faults in the induction machine using a flux sensor which measures the external radial leakage magnetic field of the machine. The procedure uses the spectral lines that correspond to the slotting effect which causes harmonics in the machine air gap. These harmonic frequencies, which are about a few kHz occur in a part of the spectra which is not very dense compared to the one that corresponds to the low frequencies due to the supply or the rotor revolution speed. The considered components can also be detected in the radial magnetic field flowing out of the machine. It can be shown that specific faults lead to additional spectral lines which appear clearly near the original ones due to the slotting effect. Two faults, which can be detected with the same magnetic flux sensor, are presented in this paper: the first one corresponds to a broken rotor bar, the second one is a stator inter turn short circuit.

[1]  G.E. Dawson,et al.  The detection of broken bars in the cage rotor of an induction machine , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[2]  H. Henao,et al.  A frequency-domain detection of stator winding faults in induction machines using an external flux sensor , 2002, Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344).

[3]  H.A. Toliyat,et al.  Interbar currents and axial fluxes in healthy and faulty induction motors , 2002, Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344).

[4]  D. Roger,et al.  Induction machine speed sensor based on stator current measurement , 1996 .

[5]  H.A. Toliyat,et al.  A novel approach for broken rotor bar detection in cage induction motors , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[6]  Gojko Joksimovic,et al.  The detection of inter-turn short circuits in the stator windings of operating motors , 2000, IEEE Trans. Ind. Electron..

[7]  C. Pachaud,et al.  Surveillance par analyse des vibrations , 1991 .

[8]  Daniel Roger,et al.  Magnetic noise reduction of induction machines , 2003 .

[9]  D. Belkhayat,et al.  Active reduction of magnetic noise in asynchronous machine controlled by stator current harmonics , 1997 .

[10]  Antonio J. Marques Cardoso,et al.  Inter-turn stator winding fault diagnosis in three-phase induction motors, by Park's Vector approach , 1997 .

[11]  W. T. Thomson,et al.  Current signature analysis to detect induction motor faults , 2001 .

[12]  J. Penman,et al.  Detection and location of interturn short circuits in the stator windings of operating motors , 1994 .

[13]  H. G. Sedding,et al.  Current monitoring for detecting inter-turn short circuits in induction motors , 2001 .

[14]  J. Brudny Modélisation de la denture des machines asynchrones. Phénomène de résonance , 1997 .