Measuring and Reflecting Depth of Anesthesia Using Wavelet and Power Spectral Density

This paper evaluates depth of anesthesia (DoA) monitoring using a new index. The proposed method preconditions raw EEG data using an adaptive threshold technique to remove spikes and low-frequency noise. We also propose an adaptive window length technique to adjust the length of the sliding window. The information pertinent to DoA is then extracted to develop a feature function using discrete wavelet transform and power spectral density. The evaluation demonstrates that the new index reflects the patient's transition from consciousness to unconsciousness with the induction of anesthesia in real time.

[1]  David L. Donoho,et al.  Nonlinear Wavelet Methods for Recovery of Signals, Densities, and Spectra from Indirect and Noisy Da , 1993 .

[2]  Michel Struys,et al.  Monitoring the depth of anaesthesia using bispectral analysis and closed-loop controlled administration of propofol , 2001 .

[3]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[4]  C. Lennmarken,et al.  Awareness during anaesthesia: a prospective case study , 2000, The Lancet.

[5]  I. Daubechies Ten Lectures on Wavelets , 1992 .

[6]  Pere Caminal,et al.  Detrended Fluctuation Analysis of EEG as a Measure of Depth of Anesthesia , 2007, IEEE Transactions on Biomedical Engineering.

[7]  S. Roberts,et al.  Increasing the depth of anesthesia assessment. , 2007, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.

[8]  J. Jakobsson,et al.  Cerebral state index during anaesthetic induction: a comparative study with propofol or nitrous oxide , 2005, Acta anaesthesiologica Scandinavica.

[9]  Fredrik Granath,et al.  Mortality Within 2 Years After Surgery in Relation to Low Intraoperative Bispectral Index Values and Preexisting Malignant Disease , 2009, Anesthesia and analgesia.

[10]  Juha Karhunen,et al.  Sinusoidal frequency estimation by signal subspace approximation , 1992, IEEE Trans. Signal Process..

[11]  D. Mathews,et al.  Increases in bispectral index lead to interventions that prevent possible intraoperative awareness. , 2005, British journal of anaesthesia.

[12]  David L. Donoho,et al.  De-noising by soft-thresholding , 1995, IEEE Trans. Inf. Theory.

[13]  Tarmo Lipping,et al.  Comparison of entropy and complexity measures for the assessment of depth of sedation , 2006, IEEE Transactions on Biomedical Engineering.

[14]  S. Roberts,et al.  EEG signal processing in anaesthesia. Use of a neural network technique for monitoring depth of anaesthesia. , 2002, British journal of anaesthesia.

[15]  Yan Li,et al.  Theoretical basis for identification of different anesthetic states based on routinely recorded EEG during operation , 2009, Comput. Biol. Medicine.

[16]  J. Hall,et al.  Bispectral index: comparison of two montages. , 1998, British journal of anaesthesia.

[17]  Sang Joon Kim,et al.  A Mathematical Theory of Communication , 2006 .

[18]  D. Tempe,et al.  Is there any alternative to the Bispectral Index Monitor? , 2004, British journal of anaesthesia.

[19]  J. Bruhn,et al.  Depth of anaesthesia monitoring: what's available, what's validated and what's next? , 2006, British journal of anaesthesia.

[20]  Yan Li,et al.  Improving the accuracy of depth of anaesthesia using modified detrended fluctuation analysis method , 2010, Biomed. Signal Process. Control..

[21]  W. Marsden I and J , 2012 .

[22]  Dong Wang,et al.  Entropy-Based Method of Choosing the Decomposition Level in Wavelet Threshold De-noising , 2010, Entropy.

[23]  Yan Li,et al.  An Improved Detrended Moving-Average Method for Monitoring the Depth of Anesthesia , 2010, IEEE Transactions on Biomedical Engineering.

[24]  Erik W. Jensen,et al.  EEG complexity as a measure of depth of anesthesia for patients , 2001, IEEE Trans. Biomed. Eng..

[25]  Kris Jamsen,et al.  Awareness During Anesthesia in Children: A Prospective Cohort Study , 2005, Anesthesia and analgesia.

[26]  R. Schmidt,et al.  Multiple source DF signal processing: An experimental system , 1986 .

[27]  S. Mallat A wavelet tour of signal processing , 1998 .

[28]  J. Bruhn,et al.  Comparability of Narcotrend index and bispectral index during propofol anaesthesia. , 2004, British journal of anaesthesia.

[29]  E. Kochs,et al.  Time Delay of Index Calculation: Analysis of Cerebral State, Bispectral, and Narcotrend Indices , 2006, Anesthesiology.

[30]  J. Bruhn,et al.  Comparability of Narcotrend index and bispectral index during propofol anaesthesia. , 2004 .

[31]  K. Heilman,et al.  Predictors of Cognitive Dysfunction after Major Noncardiac Surgery , 2008, Anesthesiology.

[32]  C. K. Yuen,et al.  Digital spectral analysis , 1979 .

[33]  Petre Stoica,et al.  Markov-based eigenanalysis method for frequency estimation , 1994, IEEE Trans. Signal Process..

[34]  I. Rampil A Primer for EEG Signal Processing in Anesthesia , 1998, Anesthesiology.

[35]  K. L. Doty Digital Spectral Analysis of Audio Signals , 1965 .

[36]  K. Kuizenga,et al.  Biphasic EEG changes in relation to loss of consciousness during induction with thiopental, propofol, etomidate, midazolam or sevoflurane. , 2001, British journal of anaesthesia.

[37]  R. Chabot,et al.  Patient state index. , 2002, Best practice & research. Clinical anaesthesiology.

[38]  J. Jakobsson,et al.  Nitrous oxide does not alter bispectral index: study with nitrous oxide as sole agent and as an adjunct to i.v. anaesthesia. , 1999, British journal of anaesthesia.

[39]  Peter S. Sebel,et al.  Development and Clinical Application of Electroencephalographic Bispectrum Monitoring , 2000, Anesthesiology.

[40]  Karen B. Domino,et al.  The Incidence of Awareness During Anesthesia: A Multicenter United States Study , 2004, Anesthesia and analgesia.

[41]  Matthias Kreuzer,et al.  Narcotrend® Does Not Adequately Detect the Transition between Awareness and Unconsciousness in Surgical Patients , 2004, Anesthesiology.

[42]  C. Lennmarken,et al.  Victims of awareness , 2002, Acta anaesthesiologica Scandinavica.

[43]  B. Bonke,et al.  Awareness and Recall during General Anesthesia: Facts and Feelings , 1993, Anesthesiology.

[44]  Simon Haykin,et al.  Adaptive filter theory (2nd ed.) , 1991 .

[45]  E Kochs,et al.  Does bispectral analysis add anything but complexity? BIS sub-components may be superior to BIS for detection of awareness. , 2004, British journal of anaesthesia.

[46]  Jeffrey C. Sigl,et al.  Anesthetic Management and One-Year Mortality After Noncardiac Surgery , 2005, Anesthesia and analgesia.

[47]  P ? ? ? ? ? ? ? % ? ? ? ? , 1991 .

[48]  Guy Albert Dumont,et al.  Quantifying cortical activity during general anesthesia using wavelet analysis , 2006, IEEE Transactions on Biomedical Engineering.

[49]  Martin Vetterli,et al.  Wavelets and filter banks: theory and design , 1992, IEEE Trans. Signal Process..

[50]  Rebecca Grant Knapp,et al.  Introductory Biostatistics for the Health Sciences. , 1984 .