Correction of motion artifacts in endoscopic optical coherence tomography and autofluorescence images based on azimuthal en face image registration

Abstract. We present a method for the correction of motion artifacts present in two- and three-dimensional in vivo endoscopic images produced by rotary-pullback catheters. This method can correct for cardiac/breathing-based motion artifacts and catheter-based motion artifacts such as nonuniform rotational distortion (NURD). This method assumes that en face tissue imaging contains slowly varying structures that are roughly parallel to the pullback axis. The method reduces motion artifacts using a dynamic time warping solution through a cost matrix that measures similarities between adjacent frames in en face images. We optimize and demonstrate the suitability of this method using a real and simulated NURD phantom and in vivo endoscopic pulmonary optical coherence tomography and autofluorescence images. Qualitative and quantitative evaluations of the method show an enhancement of the image quality.

[1]  Pierre Lane,et al.  3D-printed phantom for the characterization of non-uniform rotational distortion (Conference Presentation) , 2016, SPIE BiOS.

[2]  Brett E Bouma,et al.  Rotational distortion correction in endoscopic optical coherence tomography based on speckle decorrelation. , 2015, Optics letters.

[3]  Zhao Wang,et al.  Motion artifacts associated with in vivo endoscopic OCT images of the esophagus , 2011, Optics express.

[4]  Zhao Wang,et al.  Correction of rotational distortion for catheter-based en face OCT and OCT angiography. , 2014, Optics letters.

[5]  Pierre Lane,et al.  Endoscopic Doppler optical coherence tomography and autofluorescence imaging of peripheral pulmonary nodules and vasculature. , 2015, Biomedical optics express.

[6]  Mari Mino-Kenudson,et al.  Identifying intestinal metaplasia at the squamocolumnar junction by using optical coherence tomography. , 2007, Gastrointestinal endoscopy.

[7]  Matilda Larsson,et al.  Automatic three-dimensional registration of intravascular optical coherence tomography images. , 2012, Journal of biomedical optics.

[8]  Calum MacAulay,et al.  Multimodal tissue imaging: using coregistered optical tomography data to estimate tissue autofluorescence intensity change due to scattering and absorption by neoplastic epithelial cells , 2013, Journal of biomedical optics.

[9]  Johan G. Bosch,et al.  Azimuthal Registration of Image Sequences Affected by Nonuniform Rotation Distortion , 2008, IEEE Transactions on Information Technology in Biomedicine.

[10]  Calum MacAulay,et al.  Lung vasculature imaging using speckle variance optical coherence tomography , 2012, Photonics West - Biomedical Optics.

[11]  Pierre Lane,et al.  Endoscopic high-resolution autofluorescence imaging and OCT of pulmonary vascular networks. , 2016, Optics letters.

[12]  Brett E Bouma,et al.  Optical coherence tomography– 15 years in cardiology. , 2013, Circulation journal : official journal of the Japanese Circulation Society.

[13]  Brett E. Bouma,et al.  Optical Coherence Tomography , 2013 .

[14]  Calum MacAulay,et al.  Coregistered autofluorescence-optical coherence tomography imaging of human lung sections , 2014, Journal of biomedical optics.

[15]  Barry Vuong,et al.  In vivo feasibility of endovascular Doppler optical coherence tomography , 2012, Biomedical optics express.