Fibre optic radiation sensor systems for particle accelerators
暂无分享,去创建一个
[1] W. Gaebler. Characteristics Of Fiber Optic Radiation Detectors , 1984, Other Conferences.
[2] T. Suzuki,et al. Application of Nd3+-doped silica fibers to radiation sensing devices , 1987, Other Conferences.
[3] Peter B. Lyons,et al. Review Of High Bandwidth Fiber Optics Radiation Sensors , 1986, Optics & Photonics.
[4] H. Henschel,et al. Induced Loss After Pulsed And Continuous Irradiation Of Single Mode And Graded Index Fibres , 1989, Other Conferences.
[5] Otmar Koehn,et al. Neutron fluence and dose measurements by optical fibers , 1997, Other Conferences.
[6] R. Maurer,et al. Effect of neutron- and gamma-radiation on glass optical waveguides. , 1973, Applied optics.
[7] H. Henschel,et al. Comparison between fast neutron and gamma irradiation of optical fibres , 1997 .
[8] H. Henschel,et al. Regeneration of irradiated optical fibres by photobleaching? , 1999, 1999 Fifth European Conference on Radiation and Its Effects on Components and Systems. RADECS 99 (Cat. No.99TH8471).
[9] H. Henschel,et al. Calculation of fast neutron dose in plastic-coated optical fibres , 1997 .
[10] E. Janata. Determination of location and intensity of radiation through detection of Cherenkov emission in optical fibers. Part 1: Method and experimental , 2002 .
[11] E. Friebele. Optical Fiber Waveguides In Radiation Environments , 1979 .
[12] Ronald H. West. P-doped optical fibers in dosimetry , 2002, SPIE Remote Sensing.
[13] Gingerich,et al. Radiation-induced defects in glasses: Origin of power-law dependence of concentration on dose. , 1993, Physical review letters.
[14] Kenichi Watanabe,et al. Radiation distribution sensing with normal optical fiber , 2000 .
[15] B. J. Faraday,et al. The Fiber Optic Dosimeter on the Navigational Technology Satellite 2 , 1978, IEEE Transactions on Nuclear Science.
[16] Dennis Derickson,et al. Fiber optic test and measurement , 1998 .
[17] H. Henschel,et al. Radiation-induced loss of rare earth doped silica fibres , 1997 .
[18] H. Henschel,et al. Optical fibres as radiation dosimeters , 1992 .
[19] B. Faatz,et al. Radiation exposure and magnetic performance of the undulator system for the VUV FEL at the TESLA Test Facility Phase-1 after 3 years of operation , 2003 .
[20] B. D. Evans,et al. Permanent and transient radiation induced losses in optical fibers , 1974 .
[21] Harald Bueker,et al. Physical properties and concepts for applications of attenuation-based fiber optic dosimeters for medical instrumentation , 1992, Photonics West - Lasers and Applications in Science and Engineering.