ANALYSIS OF RIGHT VENTRICULAR REMODELING USING CURVATURE HISTOGRAM COMPARISON

Understanding and quantifying right ventricular (RV) remodeling in repaired Tetralogy of Fallot (TOF) is crucial for patient management and therapy planning, i.e., in determining the optimal time for pulmonary valve replacement. However, quantification of RV remodeling is usually hampered by its complex geometry. This paper presents a computer-aided cardiac assessment methodology to quantitate RV remodeling in terms of a histogram similarity index, based on the surface curvature distribution of three-dimensional (3D) RV geometries at both the end-diastole and end-systole phases. These 3D RV geometries are reconstructed from border delineated cardiac MRI images, whereby a surface fitting algorithm is then used to calculate the curvature distribution of the 3D models. The curvature histograms at ED and ES are computed and their similarities are measured using the Bhattacharya Similarity Metric, which is denoted as hdist. Based on an initial study involving 5 TOF patients and 5 normal subjects, we observed that the mean hdist for the normal controls is significantly higher (p = 0.0015 < 0.05 and p = 0.004 < 0.05; student t-test and Mann-Whitney- Wilcoxon test, respectively) as compared to that of the TOF patients. This suggests that hdist can be used as a discriminant between TOF patients and normal control.

[1]  Dorin Comaniciu,et al.  Real-time tracking of non-rigid objects using mean shift , 2000, Proceedings IEEE Conference on Computer Vision and Pattern Recognition. CVPR 2000 (Cat. No.PR00662).

[2]  I. Konstantinov,et al.  Late complications of repair of tetralogy of Fallot and indications for pulmonary valve replacement. , 2005, Seminars in thoracic and cardiovascular surgery.

[3]  Liang Zhong,et al.  A geometrical approach for evaluating left ventricular remodeling in myocardial infarct patients , 2012, Comput. Methods Programs Biomed..

[4]  Liang Zhong,et al.  A curvature-based approach for left ventricular shape analysis from cardiac magnetic resonance imaging , 2009, Medical & Biological Engineering & Computing.

[5]  Geoffrey I. Webb,et al.  Pulmonary valve replacement in adults late after repair of tetralogy of fallot: are we operating too late? , 2000, Journal of the American College of Cardiology.

[6]  Liang Zhong,et al.  Right ventricular regional wall curvedness and area strain in patients with repaired tetralogy of Fallot. , 2012, American journal of physiology. Heart and circulatory physiology.

[7]  T. Graham Ventricular size and function assessed by cardiac MRI predict major adverse clinical outcomes late after tetralogy of Fallot repair , 2009 .

[8]  M. Scherillo,et al.  Right ventricular myocardial dysfunction in adult patients late after repair of tetralogy of fallot. , 2004, International journal of cardiology.

[9]  R G Gould,et al.  Measurement of right and left ventricular volumes in healthy individuals with cine MR imaging. , 1987, Radiology.

[10]  A. Roos,et al.  Clinical Applications of Cardiac Magnetic Resonance Imaging After Repair of Tetralogy of Fallot , 2000, Pediatric Cardiology.

[11]  Jeroen J. Bax,et al.  Right ventricular function after pulmonary valve replacement in patients with tetralogy of Fallot. , 2004, Radiology.

[12]  Andrea J. van Doorn,et al.  Surface shape and curvature scales , 1992, Image Vis. Comput..

[13]  S. Siu,et al.  Risk factors for arrhythmia and sudden cardiac death late after repair of tetralogy of Fallot: a multicentre study , 2000, The Lancet.

[14]  G. Marx,et al.  Restoration of the Pulmonary Valve Reduces Right Ventricular Volume Overload After Previous Repair of Tetralogy of Fallot , 1993, Circulation.

[15]  Dudley J Pennell,et al.  Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance. , 2006, European heart journal.

[16]  P. D. del Nido,et al.  Patient-specific MRI-based 3D FSI RV/LV/patch models for pulmonary valve replacement surgery and patch optimization. , 2008, Journal of biomechanical engineering.

[17]  A. Zwinderman,et al.  Long-term effect of pulmonary valve replacement on QRS duration in patients with corrected tetralogy of Fallot , 2006, Heart.

[18]  Tal Geva,et al.  Indications and timing of pulmonary valve replacement after tetralogy of Fallot repair. , 2007, Seminars in thoracic and cardiovascular surgery. Pediatric cardiac surgery annual.

[19]  V. Fuster,et al.  Long-term outcome in patients undergoing surgical repair of tetralogy of Fallot. , 1993, The New England journal of medicine.