Patellofemoral evaluation after total knee arthroplasty. Validation of a new weight-bearing axial radiographic view.

BACKGROUND Radiographic assessment of the patella after total knee arthroplasty is typically performed with use of static, unloaded views that may not reproduce the in vivo patellofemoral kinematics. The purpose of the present study was to evaluate and validate the reliability and reproducibility of a weight-bearing radiographic assessment of the patellofemoral joint in patients who have undergone total knee arthroplasty. METHODS Radiographs were made for 100 knees in sixty-nine patients who had undergone total knee arthroplasty. Radiographic assessment of the patellofemoral joint was performed with use of both the standard Merchant axial view and a modification of that view. The Merchant axial view was modified by positioning the standing patient in the semi-squatted position with the knees in 45 degrees of flexion. The relationship between the x-ray source, the angle of incidence on the joint, and the cassette position was kept unchanged from the original view. The standing position and consequent muscle involvement were the only differences. RESULTS Compared with the standard Merchant axial view, the weight-bearing axial view showed a number of patellofemoral tracking changes. Specifically, lateral tilt and subluxation of the patella were significantly reduced; the rate of exposed, uncovered patellar bone contact with the femoral trochlea was significantly increased; and radiographic evidence of maltracking was more closely correlated with clinical symptoms. CONCLUSIONS An axial weight-bearing radiographic view with the patient in the semi-squatting position was developed to reproduce patellofemoral joint loading. This view demonstrates that the position of the patella, as seen on the standard unloaded Merchant view, changes during squatting. Utilization of this axial weight-bearing view to evaluate total knee arthroplasty may provide additional information over standard radiographic views.

[1]  L. S. M. Gomes,et al.  Patellar prosthesis positioning in total knee arthroplasty , 1988 .

[2]  S. Koskinen,et al.  Dynamic Lateral Patellar Tilt in the Anterior Cruciate Ligament-Deficient Knee , 2001, The American journal of sports medicine.

[3]  S. Tennant,et al.  Patello-femoral tracking in the weight-bearing knee: a study of asymptomatic volunteers utilising dynamic magnetic resonance imaging: a preliminary report , 2001, Knee Surgery, Sports Traumatology, Arthroscopy.

[4]  C. Ranawat,et al.  The patellofemoral joint in total condylar knee arthroplasty. Pros and cons based on five- to ten-year follow-up observations. , 1986, Clinical orthopaedics and related research.

[5]  Michael J Dunbar,et al.  Extensor Mechanism Failure Associated With Total Knee Arthroplasty: Prevention and Management , 2003, The Journal of the American Academy of Orthopaedic Surgeons.

[6]  R. Buzzi,et al.  Patellofemoral functional results and complications with the posterior stabilized total condylar knee prosthesis. , 1988, The Journal of arthroplasty.

[7]  J. Toft Stress radiography of the patello-femoral joint. , 1981, Italian journal of orthopaedics and traumatology.

[8]  K. M. Singer,et al.  Patellofemoral disorders: physical and radiographic evaluation. Part II: Radiographic examination. , 1984, Clinical orthopaedics and related research.

[9]  D E Dupuy,et al.  Kinematic CT of the patellofemoral joint. , 1997, AJR. American journal of roentgenology.

[10]  A. C. Merchant,et al.  Roentgenographic analysis of patellofemoral congruence. , 1974, The Journal of bone and joint surgery. American volume.

[11]  F G Shellock,et al.  Development and clinical application of kinematic MRI of the patellofemoral joint using an extremity MR system. , 1999, Medicine and science in sports and exercise.

[12]  F. Shellock,et al.  Assessment of patellofemoral relationships using kinematic MRI: Comparison between qualitative and quantitative methods , 2002, Journal of magnetic resonance imaging : JMRI.

[13]  R. P. Csintalan,et al.  The influence of tibial and femoral rotation on patellofemoral contact area and pressure. , 2003, The Journal of orthopaedic and sports physical therapy.

[14]  M. Pagnano,et al.  Asymmetric patella resurfacing in total knee arthroplasty. , 2000, The American journal of knee surgery.

[15]  R. Scott,et al.  The patellofemoral component of total knee arthroplasty. , 1988, Clinical orthopaedics and related research.

[16]  T. Q. Lee,et al.  The influence of fixed rotational deformities of the femur on the patellofemoral contact pressures in human cadaver knees. , 1994, Clinical orthopaedics and related research.

[17]  Eugene Ozhinsky,et al.  Magnetic resonance imaging of patellofemoral kinematics with weight-bearing. , 2003, The Journal of bone and joint surgery. American volume.

[18]  N. Egund,et al.  The Axial View of the Patello-Femoral Joint , 1986, Acta radiologica: diagnosis.

[19]  Scott Rd Prosthetic replacement of the patellofemoral joint. , 1979 .

[20]  Samuel R Ward,et al.  Patellofemoral kinematics during weight-bearing and non-weight-bearing knee extension in persons with lateral subluxation of the patella: a preliminary study. , 2003, The Journal of orthopaedic and sports physical therapy.

[21]  S. Verhulst,et al.  Patellar tilt in total knee arthroplasty. , 1996, American journal of orthopedics.

[22]  A. Tria,et al.  Resurfacing of the patella. , 1980, The Journal of bone and joint surgery. American volume.

[23]  Yi-Fen Shih,et al.  Measurement of Patellar Tracking: Assessment and Analysis of the Literature , 2003, Clinical orthopaedics and related research.

[24]  F. C. Ewald Leg-lift technique for simultaneous femoral, tibial, and patellar prosthetic cementing, “rule of no thumb ” for patellar tracking, and steel rod rule for ligament tension , 1991 .

[25]  O. Karaoğlan,et al.  Kinematic and dynamic axial computed tomography of the patello-femoral joint in patients with anterior knee pain , 2005, Knee Surgery, Sports Traumatology, Arthroscopy.

[26]  E. Salvati,et al.  Patella position in the normal knee joint. , 1971, Radiology.

[27]  K. An,et al.  The influence of weakness in the vastus medialis oblique muscle on the patellofemoral joint: an in vitro biomechanical study. , 2000, Clinical biomechanics.

[28]  D. Eckhoff,et al.  Lateral patellar burnishing in total knee arthroplasty following medialization of the patellar button. , 1995, The Journal of arthroplasty.

[29]  H. Labelle,et al.  The abnormal lateral patellofemoral angle: a diagnostic roentgenographic sign of recurrent patellar subluxation. , 1978, The Journal of bone and joint surgery. American volume.

[30]  B. Masri,et al.  The effect of knee flexion and quadriceps contraction on the axial view of the patella. , 1995, Clinical journal of sport medicine : official journal of the Canadian Academy of Sport Medicine.

[31]  A. Amis,et al.  Patellofemoral malalignment: looking beyond the viewbox. , 2002, Clinics in sports medicine.

[32]  K. Vince,et al.  Patellar tilt and subluxation following subvastus and parapatellar approach in total knee arthroplasty. Implication for surgical technique. , 1996, The Journal of arthroplasty.

[33]  L. Whiteside,et al.  The effect of patellar button placement and femoral component design on patellar tracking in total knee arthroplasty. , 1992, Clinical orthopaedics and related research.

[34]  L. Dorr,et al.  Patellar tilt and subluxation in total knee arthroplasty. Relationship to pain, fixation, and design. , 1993, Clinical orthopaedics and related research.

[35]  Turner Gw,et al.  Erect position/tangential projection of the patellofemoral joint. , 1982 .

[36]  L. Dorr,et al.  Rationale of the Knee Society clinical rating system. , 1989, Clinical orthopaedics and related research.

[37]  J. Rand Patellar resurfacing in total knee arthroplasty. , 1990, Clinical orthopaedics and related research.

[38]  J E Bechtold,et al.  Patellar prosthesis positioning in total knee arthroplasty. A roentgenographic study. , 1988, Clinical orthopaedics and related research.

[39]  J D Reuben,et al.  The effect of femoral component position on the kinematics of total knee arthroplasty. , 1993, Clinical orthopaedics and related research.

[40]  J. P. Peden,et al.  Accuracy of haptic assessment of patellar symmetry in total knee arthroplasty. , 2004, The Journal of arthroplasty.

[41]  S. Harwin Patellofemoral complications in symmetrical total knee arthroplasty. , 1998, The Journal of arthroplasty.

[42]  R. Barrack,et al.  An analysis of Food and Drug Administration medical device reports relating to total joint components. , 1997, The Journal of arthroplasty.

[43]  D. Hungerford,et al.  Eliminating patellofemoral complications in total knee arthroplasty: clinical and radiographic results of 121 consecutive cases using the Duracon system. , 1999, The Journal of arthroplasty.

[44]  J. C. Hughston Subluxation of the patella. , 1968, The Journal of bone and joint surgery. American volume.