The benefits of combining utility-controlled demand response with residential zoned cooling

This paper evaluates the effectiveness of combining direct load control with a residential zoned-cooling technology in meeting the objectives of reducing peak demand and maintaining home comfort level. In contrast, the traditional approach has been for utilities to smooth summer peak cooling loads, by controlling the cooling load of the whole house. While accounting for weather, dwelling characteristics and demographics, with detailed field data, we are able to develop empirical models to evaluate the benefits of utility control of cooling loads for a residential zoned cooling system during summer peak-demand periods and to compare with non-zoned systems. A zoned house allows for an upper floor cooling interruption without affecting the comfort on the main floor. An upper floor interruption for a full 4 h during the day leads to an average peak air conditioning change of −0.52 kW, approximately 1.6 times the reduction from the curtailment of cooling by cycling the air conditioning serving the whole house.