Image guidance of endovascular interventions on a clinical MR scanner

Magnetic resonance imaging (MRI) offers potential advantages over conventional X-ray techniques for guiding and evaluating vascular interventions. Image guidance of such interventions via passive catheter tracking requires real-time image processing. Commercially available MR scanners currently do not provide this functionality. This paper describes an image processing environment that allows near-real-time MR-guided vascular interventions. It demonstrates (1) that flexibility can be achieved by separating the scanner and the image processing/display system, thereby preserving the stability of the scanner and (2) that sufficiently rapid visualization can be achieved by low-cost workstations equipped with graphics hardware. The setup of the hardware and the software is described in detail. Furthermore, image processing techniques are presented for guiding the interventionalist through simple vascular anatomy. Finally, results of a phantom balloon angioplasty experiment are presented.

[1]  Brent B. Welch Practical programming in Tcl and TK (2. ed.) , 1997 .

[2]  S J Riederer,et al.  Real‐time MR fluoroscopic data acquisition and image reconstruction , 1989, Magnetic resonance in medicine.

[3]  C L Dumoulin,et al.  Intravascular MR tracking catheter: preliminary experimental evaluation. , 1995, AJR. American journal of roentgenology.

[4]  M A Viergever,et al.  MR-guided endovascular interventions: susceptibility-based catheter and near-real-time imaging technique. , 1997, Radiology.

[5]  Tomoyuki Haishi,et al.  Real-Time NMR Imaging Systems Using Personal Computers , 1997 .

[6]  R. Lufkin,et al.  Interventional MR imaging. , 1995, Radiology.

[7]  Tom Duff,et al.  Compositing digital images , 1984, SIGGRAPH.

[8]  Douglas A. Ortendahl,et al.  Fluoroscopic MR imaging at 0.064 Tesla , 1991 .

[9]  Kullervo Hynynen,et al.  MR temperature mapping of focused ultrasound surgery , 1994, Magnetic resonance in medicine.

[10]  D L Rubin,et al.  Magnetic susceptibility effects and their application in the development of new ferromagnetic catheters for magnetic resonance imaging. , 1990, Investigative radiology.

[11]  K J Zuiderveld,et al.  MR‐guided balloon angioplasty: In vitro demonstration of the potential of MRI for guiding, monitoring, and evaluating endovascular interventions , 1998, Journal of magnetic resonance imaging : JMRI.

[12]  J N Lee,et al.  MR fluoroscopy: Technical feasibility , 1988, Magnetic resonance in medicine.

[13]  F A Jolesz,et al.  Interventional use of magnetic resonance imaging. , 1994, Magnetic resonance quarterly.

[14]  P. Röschmann,et al.  Susceptibility artefacts in NMR imaging. , 1985, Magnetic resonance imaging.

[15]  R W Cox,et al.  Real‐Time Functional Magnetic Resonance Imaging , 1995, Magnetic resonance in medicine.

[16]  E Grabbe,et al.  MR imaging-guided breast intervention: experience with two systems. , 1995, Radiology.

[17]  J. J. van Vaals,et al.  “Keyhole” method for accelerating imaging of contrast agent uptake , 1993, Journal of magnetic resonance imaging : JMRI.

[18]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[19]  C J Hardy,et al.  Real‐time interactive MRI on a conventional scanner , 1997, Magnetic resonance in medicine.

[20]  F. Jolesz,et al.  Interactive MR-guided biopsy in an open-configuration MR imaging system. , 1995, Radiology.

[21]  F A Jolesz,et al.  Focused US system for MR imaging-guided tumor ablation. , 1995, Radiology.

[22]  A F Gmitro,et al.  A real‐time reconstruction system for magnetic resonance imaging , 1996, Magnetic resonance in medicine.

[23]  C L Dumoulin,et al.  MR imaging-guided intravascular procedures: initial demonstration in a pig model. , 1997, Radiology.

[24]  G. Adam,et al.  Interactive MR Fluoroscopy on a Clinical Scanner , .

[25]  S. Souza,et al.  Real‐time position monitoring of invasive devices using magnetic resonance , 1993, Magnetic resonance in medicine.

[26]  Remko van der Weide,et al.  Hemodialysis Access Flow Phantom , 1998 .

[27]  M A Viergever,et al.  Visualization of dedicated catheters using fast scanning techniques with potential for MR‐guided vascular interventions , 1996, Magnetic resonance in medicine.