Modeling pulsatile flow in aortic aneurysms: effect of non-Newtonian properties of blood.

Pulsatile flow in an axisymmetric rigid-walled model of an abdominal aorta aneurysm was analyzed numerically for various aneurysm dilations using physiologically realistic resting waveform at time-averaged Reynolds number of 300 and peak Reynolds number of 1607. Discretization of the governing equations was achieved using a finite element scheme based on the Galerkin method of weighted residuals. Comparisons with previously published work on the basis of special cases were performed and found to be in excellent agreement. Our findings indicate that the velocity fields are significantly affected by non-Newtonian properties in pathologically altered configurations. Non-Newtonian fluid shear stress is found to be greater than Newtonian fluid shear stress during peak systole. Further, the maximum shear stress is found to occur near the distal end of AAA during peak systole. The impact of non-Newtonian blood flow characteristics on pressure compared to Newtonian model is found insignificant under resting conditions. Viscous and inertial forces associated with blood flow are responsible for the changes in the wall that result in thrombus deposition and dilation while rupture of AAA is more likely determined by much larger mechanical stresses imposed by pulsatile pressure on the wall of AAA.

[1]  D. Brewster,et al.  Autopsy Study of Unoperated Abdominal Aortic Aneurysms: The Case for Early Resection , 1977, Circulation.

[2]  Robert A Peattie,et al.  Pulsatile flow in fusiform models of abdoiminal aortic aneurysms: flow fields, velocity patterns and flow-induced wall stresses. , 2004, Journal of biomechanical engineering.

[3]  R. Budwig,et al.  Steady flow in abdominal aortic aneurysm models. , 1993, Journal of biomechanical engineering.

[4]  L P Chua,et al.  A numerical investigation on the steady and pulsatile flow characteristics in axi-symmetric abdominal aortic aneurysm models with some experimental evaluation. , 1999, Journal of medical engineering & technology.

[5]  T. Fukushima,et al.  Visualization and finite element analysis of pulsatile flow in models of the abdominal aortic aneurysm. , 1989, Biorheology.

[6]  Hun Jung,et al.  Asymmetric flows of non-Newtonian fluids in symmetric stenosed artery , 2004 .

[7]  A. J. Valente,et al.  Regulation of low shear flow-induced HAEC VCAM-1 expression and monocyte adhesion. , 1999, American journal of physiology. Cell physiology.

[8]  P. Hood,et al.  A numerical solution of the Navier-Stokes equations using the finite element technique , 1973 .

[9]  E A Finol,et al.  The effect of asymmetry in abdominal aortic aneurysms under physiologically realistic pulsatile flow conditions. , 2003, Journal of biomechanical engineering.

[10]  A P Yoganathan,et al.  Two-dimensional velocity measurements in a pulsatile flow model of the normal abdominal aorta simulating different hemodynamic conditions. , 1993, Journal of biomechanics.

[11]  T W Taylor,et al.  Three-dimensional simulation of blood flow in an abdominal aortic aneurysm--steady and unsteady flow cases. , 1994, Journal of biomechanical engineering.

[12]  Y. Cho,et al.  Effects of the non-Newtonian viscosity of blood on flows in a diseased arterial vessel. Part 1: Steady flows. , 1991, Biorheology.

[13]  E A Finol,et al.  Blood flow in abdominal aortic aneurysms: pulsatile flow hemodynamics. , 2001, Journal of biomechanical engineering.

[14]  H. Steiger,et al.  Hemodynamic stress in lateral saccular aneurysms. , 1987 .

[15]  J P Shillingford,et al.  Pressure-flow relationships and vascular impedance in man. , 1970, Cardiovascular research.

[16]  E M Pedersen,et al.  Pulsatile flow visualization in a model of the human abdominal aorta and aortic bifurcation. , 1992, Journal of biomechanics.

[17]  R. Sani,et al.  On the time-dependent solution of the incompressible Navier-Stokes equations in two and three dimensions , 1980 .

[18]  R. Budwig,et al.  Model studies of the flow in abdominal aortic aneurysms during resting and exercise conditions. , 1999, Journal of biomechanics.

[19]  S S Gambhir,et al.  Effect of intraluminal thrombus on abdominal aortic aneurysm wall stress. , 1997, Journal of vascular surgery.

[20]  L Niu,et al.  Steady flow in an aneurysm model: correlation between fluid dynamics and blood platelet deposition. , 1996, Journal of biomechanical engineering.

[21]  A. Leuprecht,et al.  Computer Simulation of Non-Newtonian Effects on Blood Flow in Large Arteries , 2001, Computer methods in biomechanics and biomedical engineering.

[22]  K. Perktold On the paths of fluid particles in an axisymmetrical aneurysm. , 1987, Journal of biomechanics.

[23]  Flow Studies in a Model of the Abdominal Aorta , 1990 .

[24]  Charles A. Taylor,et al.  In Vivo Validation of Numerical Prediction of Blood Flow in Arterial Bypass Grafts , 2002, Annals of Biomedical Engineering.

[25]  Michael M. Resch,et al.  Pulsatile non-Newtonian flow characteristics in a three-dimensional human carotid bifurcation model. , 1991, Journal of biomechanical engineering.