Comparison of CFD and MRI Flow and Velocities in an In Vitro Large Artery Bypass Graft Model

Bypass graft failures have been attributed to various hemodynamic factors, including flow stasis and low shear stress. Ideally, surgeries would minimize the occurrence of these detrimental flow conditions, but surgeons cannot currently assess this. Numerical simulation techniques have been proposed as one method for predicting changes in flow distributions and patterns from surgical bypass procedures, but comparisons against experimental results are needed to assess their usefulness. Previous in vitro studies compared simulated results against experimentally obtained measurements, but they focused on peripheral arteries, which have lower Reynolds numbers than those found in the larger arteries. In this study, we compared simulation results against measurements obtained using magnetic resonance imaging (MRI) techniques for a phantom model of a stenotic vessel with a bypass graft under conditions suitable for surgical planning purposes and with inlet Reynolds numbers closer to those found in the larger arteries. Comparisons of flow rate and velocity profiles were performed at maximum and minimum flows at four locations and used simulation results that were temporally and spatially averaged, key postprocessing when comparing against phase contrast MRI measurements. The maximum error in the computed volumetric flow rates was 6% of the measured values, and excellent qualitative agreement was obtained for the through-plane velocity profiles in both magnitude and shape. The in-plane velocities also agreed reasonably well at most locations.

[1]  R. Whitmore,et al.  Rheology of the circulation , 1968 .

[2]  W. Daenen,et al.  Aortofemoral grafting: factors influencing late results. , 1980, Surgery.

[3]  D. Giddens,et al.  Characterization and evolution poststenotic flow disturbances. , 1981, Journal of biomechanics.

[4]  C. Zarins,et al.  Carotid Bifurcation Atherosclerosis: Quantitative Correlation of Plaque Localization with Flow Velocity Profiles and Wall Shear Stress , 1983, Circulation research.

[5]  G. Hutchins,et al.  Arterial geometry affects hemodynamics. A potential risk factor for athersoclerosis. , 1983, Atherosclerosis.

[6]  D. Brewster,et al.  Factors affecting patency of femoropopliteal bypass grafts. , 1983, Surgery, gynecology & obstetrics.

[7]  D N Firmin,et al.  Blood flow imaging by cine magnetic resonance. , 1986, Journal of computer assisted tomography.

[8]  J. S. Yao,et al.  Technical defects as a cause of early graft failure after femorodistal bypass. , 1987, Archives of surgery.

[9]  R. Herfkens,et al.  Phase contrast cine magnetic resonance imaging. , 1991, Magnetic resonance quarterly.

[10]  S Glagov,et al.  Anastomotic intimal hyperplasia: mechanical injury or flow induced. , 1992, Journal of vascular surgery.

[11]  N J Pelc,et al.  Quantitative magnetic resonance flow imaging. , 1994, Magnetic resonance quarterly.

[12]  J C Gore,et al.  Validation of volume flow measurements with cine phase‐contrast MR imaging for peripheral arterial waveforms , 1995, Journal of magnetic resonance imaging : JMRI.

[13]  J. Freischlag,et al.  Ongoing vascular laboratory surveillance is essential to maximize long-term in situ saphenous vein bypass patency. , 1996, Journal of Vascular Surgery.

[14]  R Frayne,et al.  MR measurement and numerical simulation of steady flow in an end-to-side anastomosis model. , 1996, Journal of biomechanics.

[15]  C. R. Ethier,et al.  Flow waveform effects on end-to-side anastomotic flow patterns. , 1998, Journal of biomechanics.

[16]  M. Alley,et al.  Ultrafast contrast-enhanced three-dimensional MR angiography: state of the art. , 1998, Radiographics : a review publication of the Radiological Society of North America, Inc.

[17]  Thomas J. R. Hughes,et al.  Finite element modeling of blood flow in arteries , 1998 .

[18]  B. Rutt,et al.  Hemodynamics of human carotid artery bifurcations: computational studies with models reconstructed from magnetic resonance imaging of normal subjects. , 1998, Journal of vascular surgery.

[19]  B. Kuban,et al.  Validated computation of physiologic flow in a realistic coronary artery branch. , 1997, Journal of biomechanics.

[20]  C. Taylor,et al.  Predictive medicine: computational techniques in therapeutic decision-making. , 1999, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[21]  F. N. van de Vosse,et al.  The influence of the non-Newtonian properties of blood on the flow in large arteries: steady flow in a carotid bifurcation model. , 1999, Journal of biomechanics.

[22]  D Saloner,et al.  Influence of stenosis morphology on flow through severely stenotic vessels: implications for plaque rupture. , 2000, Journal of biomechanics.

[23]  C. R. Ethier,et al.  Steady flow separation patterns in a 45 degree junction , 2000, Journal of Fluid Mechanics.

[24]  René M. Botnar,et al.  Hemodynamics in the carotid artery bifurcation: a comparison between numerical simulations and in vitro MRI measurements. , 2000, Journal of biomechanics.

[25]  D. Giddens,et al.  Pulsatile flow in an end-to-side vascular graft model: comparison of computations with experimental data. , 2001, Journal of biomechanical engineering.

[26]  C Bertolotti,et al.  Numerical and experimental models of post-operative realistic flows in stenosed coronary bypasses. , 2001, Journal of biomechanics.

[27]  D J Doorly,et al.  Assessing the accuracy of two‐dimensional phase‐contrast MRI measurements of complex unsteady flows , 2001, Journal of magnetic resonance imaging : JMRI.

[28]  M. Kahn,et al.  Comparative decades of experience with glutaraldehyde-tanned human umbilical cord vein graft for lower limb revascularization: an analysis of 1275 cases. , 2002, Journal of vascular surgery.

[29]  Christopher J. Elkins,et al.  Rapid In-Vitro Physiologic Flow Experimentation Using Rapid Prototyping and Particle Image Velocimetry , 2003 .

[30]  Ryan B. Wicker,et al.  Rapid experimentation in complex internal flow passages using SLA and MRV , 2003 .

[31]  Gerald M. Saidel,et al.  Role of O2 in Regulation of Lactate Dynamics during Hypoxia: Mathematical Model and Analysis , 2004, Annals of Biomedical Engineering.

[32]  Thomas J. R. Hughes,et al.  Finite Element Modeling of Three-Dimensional Pulsatile Flow in the Abdominal Aorta: Relevance to Atherosclerosis , 2004, Annals of Biomedical Engineering.

[33]  Charles A. Taylor,et al.  In Vivo Validation of Numerical Prediction of Blood Flow in Arterial Bypass Grafts , 2002, Annals of Biomedical Engineering.

[34]  Graves Ej,et al.  National Hospital Discharge Survey , 2004 .