Calculation of critical loading condition with nose curve using homotopy continuation method

A new method is presented for calculating the nose curves and critical loading conditions of power systems. The nose curve (PV curve), which donates the relationship between total load and system voltages, is calculated by a new approach based on the homotopy continuation method. The critical loading condition, which might be called the bifurcation point, is also calculated precisely as the final point of the nose curve. This method does not require an exhausting cut-and-try process or a rough-approximation process. It is based on the conventional Newton-Raphson load flow calculation, but it overcomes the numerical difficulties associated with the singularity of the Jacobian matrix. The results of applying the proposed method to the IEEE 118-bus system and to other large practical systems (e.g., a 496-bus system) verify its robustness and feasibility. >

[1]  Jerome Meisel,et al.  The Generation of Quasi Steady-State Load-Flow Trajectories and Multiple Singular Point Solutions , 1971 .

[2]  G. Reddien On Newton’s Method for Singular Problems , 1978 .

[3]  J. Yorke,et al.  The homotopy continuation method: numerically implementable topological procedures , 1978 .

[4]  Y. Tamura,et al.  Relationship Between Voltage Instability and Multiple Load FLow Solutions in Electric Power Systems , 1983, IEEE Transactions on Power Apparatus and Systems.

[5]  J. Carpentier,et al.  VOLTAGE COLLAPSE PROXIMITY INDICATORS COMPUTED FROM AN OPTIMAL POWER FLOW , 1984 .

[6]  G. Price,et al.  A Generalized Circle Diagram Approach For Global Analysis Of Transmission System Performance , 1984, IEEE Transactions on Power Apparatus and Systems.

[7]  A. Griewank On Solving Nonlinear Equations with Simple Singularities or Nearly Singular Solutions , 1985 .

[8]  Leon Y. Bahar,et al.  Static bifurcations in electric power networks: Loss of steady-state stability and voltage collapse , 1986 .

[9]  H. Glavitsch,et al.  Estimating the Voltage Stability of a Power System , 1986, IEEE Transactions on Power Delivery.

[10]  R. Fischl,et al.  An Algorithm for Automatically Tuning the Weights of Performance Indices for Monitoring Power System Loading or Security , 1986, IEEE Transactions on Power Systems.

[11]  Marija Ilic-Spong,et al.  Discrete Models of Slow Voltage Dynamics for Under Load Tap-Changing Transformer Coordination , 1987, IEEE Power Engineering Review.

[12]  Robert J. Thomas,et al.  A posturing strategy against voltage instabilities in electric power systems , 1988 .

[13]  R.J. Thomas,et al.  On voltage collapse in electric power systems , 1989, Conference Papers Power Industry Computer Application Conference.

[14]  A.G. Phadke,et al.  Dynamic simulation of voltage collapse , 1989, Conference Papers Power Industry Computer Application Conference.

[15]  K. Iba,et al.  A method for finding a pair of multiple load flow solutions in bulk power systems , 1989, Conference Papers Power Industry Computer Application Conference.

[16]  Y. Sekine,et al.  Cascaded voltage collapse , 1990 .

[17]  A. Semlyen,et al.  Calculation of the extreme loading condition of a power system for the assessment of voltage stability , 1991, IEEE Power Engineering Review.