Algorithm for design of controlled motion of adjacent structures

This paper presents a versatile and robust algorithm for the optimal design of adjacent structural systems linked by passive energy dissipation devices. The algorithm works both with stationary and nonstationary force input. It is a two-stage design procedure that (i) determines an active control law, and then (ii) adds damper and stiffness coefficients that are computed based on the minimization of the difference between the response of the actively controlled system and an equivalent passive control system. The algorithm is an iterative procedure that leads to a close form global optimal solution for the damping and stiffness coefficients in such a way to obtain a response as close as possible to the active control. The method is tested for two adjacent ten-degree-of-freedom spring-dashpot-mass systems. Sensitivity analysis is carried out studying the effects of period variation, the number of DOFs variation and link location using a stationary band-limited white noise input as ground acceleration. Results show that the same performance can be achieved with less amount of damping when the linear damper is located at the last mass of the system. When dampers are located in one of the node of the mode shape, the total amount of damping is higher to achieve the same performance. Copyright © 2009 John Wiley & Sons, Ltd.

[1]  B. F. Spencer,et al.  Active Structural Control: Theory and Practice , 1992 .

[2]  Gian Paolo Cimellaro Improving seismic resilience of structural systems through integrated design of smart structures , 2007 .

[3]  Tomaso Trombetti,et al.  ADDED VISCOUS DAMPERS IN SHEAR-TYPE STRUCTURES: THE EFFECTIVENESS OF MASS PROPORTIONAL DAMPING , 2004 .

[4]  Yl L. Xu,et al.  Dynamic response of damper-connected adjacent buildings under earthquake excitation , 1999 .

[5]  Andrei M. Reinhorn,et al.  Design of Supplemental Dampers for Control of Structures , 1996 .

[6]  Erik A. Johnson,et al.  Semiactive Connected Control Method for Adjacent Multidegree-of-Freedom Buildings , 2007 .

[7]  R. E. Klein,et al.  Semi-Active Control of Wind Induced Oscillations in Structures , 1987 .

[8]  R. S. Jangid,et al.  Seismic analysis of structures connected with friction dampers , 2006 .

[9]  Bruce D. Westermo,et al.  The dynamics of interstructural connection to prevent pounding , 1989 .

[10]  I. Takewaki An approach to stiffness-damping simultaneous optimization , 2000 .

[11]  Jinkoo Kim,et al.  Seismic performance of structures connected by viscoelastic dampers , 2006 .

[12]  Yl L. Xu,et al.  Experimental Seismic Study of Adjacent Buildings with Fluid Dampers , 2003 .

[13]  Andre Filiatrault,et al.  Nonlinear earthquake response of structurally interconnected buildings , 1992 .

[14]  Fumio Doi,et al.  Bending and Torsional Vibration Control for Flexible Structures arranged in Parallel. , 1998 .

[15]  J. Enrique Luco,et al.  Optimal damping between two adjacent elastic structures , 1998 .

[16]  Andrei M. Reinhorn,et al.  Evaluation, Prevention and Mitigation of Pounding Effects in Building Structures , 1997 .