Accuracy analysis of automatic distortion correction

The paper addresses the problem of the automatic distortion removal from images acquired with non-metric SLR camera equipped with prime lenses. From the photogrammetric point of view the following question arises: is the accuracy of distortion control data provided by the manufacturer for a certain lens model (not item) suffi cient in order to achieve demanded accuracy? In order to obtain the reliable answer to the aforementioned problem the two kinds of tests were carried out for three lens models. Firstly the multi-variant camera calibration was conducted using the software providing full accuracy analysis. Secondly the accuracy analysis using check points took place. The check points were measured in the images resampled based on estimated distortion model or in distortion-free images simply acquired in the automatic distortion removal mode. The extensive conclusions regarding application of each calibration approach in practice are given. Finally the rules of applying automatic distortion removal in photogrammetric measurements are suggested.

[1]  L. Grammatikopoulos,et al.  A UNIFIED APPROACH FOR AUTOMATIC CAMERA CALIBRATION FROM VANISHING POINTS , 2006 .

[2]  Carlos Ricolfe-Viala,et al.  Correcting non-linear lens distortion in cameras without using a model , 2010 .

[3]  E. Pastucha Research on the influence of the approximated principal distance on the accuracy of orthophotoplans out of historic polychrome (on flat and quasi-flat surface) , 2012 .

[4]  R. Tokarczyk,et al.  Ocena dokładności rekonstrukcji obiektu z wykorzystaniem aparatu cyfrowego Kodak DC 260 , 1999 .

[5]  T. Clarke,et al.  The Development of Camera Calibration Methods and Models , 1998 .

[6]  Anuar Ahmad,et al.  Calibration of high resolution digital camera based on different photogrammetric methods , 2014 .

[7]  Duane C. Brown,et al.  Close-Range Camera Calibration , 1971 .

[8]  R. Tokarczyk,et al.  Automatyczna identyfikacja punktów pola testowego AGH z wykorzystaniem pakietu MATLAB , 2007 .

[9]  R. Tokarczyk,et al.  Wykorzystanie aparatu cyfrowego telefonu komórkowego do wizualizacji 3D kapliczki , 2007 .

[10]  João Pedro Barreto,et al.  A New Solution for Camera Calibration and Real-Time Image Distortion Correction in Medical Endoscopy–Initial Technical Evaluation , 2012, IEEE Transactions on Biomedical Engineering.

[11]  Έλλη Πέτσα,et al.  A unified approach for automatic camera calibration from vanishing points , 2015 .

[12]  Dystorsja obiektywów kamer termograficznych , 2011 .

[13]  Joris J.J. Dirckx,et al.  Real-time geometric lens distortion correction using a graphics processing unit , 2012 .