CCD Optical Tomography System to Detect Solid Contamination in Crystal-Clear Water

The existence of foreign objects in crystal-clear water in beverage industries may cause major safety and health issues. The current observation of solid contamination such as X-ray and metal detector involves hazardous radiation. Some of the sensors applied intrusive and invasive techniques. This may cause the instability of the process flow. Therefore, this paper aims to develop a noninvasive and nonintrusive charge-coupled device optical tomography (CCD OPT) system to detect solid contamination in crystal-clear water. Investigations on three different opacity levels of objects, opaque, translucent, and transparent, are involved. The first experiment investigates the velocity and acceleration of the free-falling object. It is conducted to validate the accuracy of the system to detect the appearance of foreign object. The experiment result indicated that the system reached 82% accuracy. The second experiment reconstructs cross-sectional image of the process flow. The image reconstruction results are analyzed using the area error (AE) method. The image reconstruction AE range is between 0.0372 and 0.7269. The AE results show that the system has the capability to detect different opacity of objects which exist in crystal-clear water. Both experiments prove that the CCD OPT system is able to detect solid contamination in crystal-clear water.

[1]  R. G. Jackson Chapter 10 – The development of optical systems for process imaging , 1995 .

[2]  Zhaozheng Yin,et al.  Seeing the invisible in differential interference contrast microscopy images , 2016, Medical Image Anal..

[3]  Ruzairi Abdul Rahim,et al.  Analysis on the Effect of Sensor Views in Image Reconstruction Produced by Optical Tomography System Using Charge-Coupled Device , 2018, IEEE Transactions on Image Processing.

[4]  Sallehuddin Ibrahim Measurement of gas bubbles in a vertical water column using optical tomography. , 2000 .

[5]  Sadao Yamazaki,et al.  Basic analysis of a metal detector , 2002, IEEE Trans. Instrum. Meas..

[6]  Simon R. Arridge,et al.  Application of the finite-element method for the forward and inverse models in optical tomography , 1993, Journal of Mathematical Imaging and Vision.

[7]  Juliza Jamaludin,et al.  Optical tomography system using charge-coupled device , 2016 .

[8]  Jinhui Tang,et al.  Multi-Grained Random Fields for Mitosis Identification in Time-Lapse Phase Contrast Microscopy Image Sequences , 2017, IEEE Transactions on Medical Imaging.

[9]  Takeo Kanade,et al.  Automated Mitosis Detection of Stem Cell Populations in Phase-Contrast Microscopy Images , 2011, IEEE Transactions on Medical Imaging.

[10]  R. A. Rahim,et al.  Charge coupled device based on optical tomography system in detecting air bubbles in crystal clear water , 2016 .

[11]  Joanna Trafialek,et al.  The Risk Analysis of Metallic Foreign Bodies in Food Products , 2016 .

[12]  Juliza Jamaludin,et al.  Charge-coupled device based on optical tomography system for monitoring two-phase flow , 2017 .

[13]  Mohd Hafiz Fazalul Rahiman,et al.  Simulation Study of Microwave Imaging for Brain Disease Diagnostic , 2018 .

[14]  Juliza Jamaludin Optical tomography system for bubbles detection in liquid medium , 2013 .

[15]  Kihong Park,et al.  Application of laser-induced breakdown spectroscopy for real-time detection of contamination particles during the manufacturing process. , 2018, Applied optics.

[16]  Ruzairi Abdul Rahim,et al.  Online Optical Tomography System for Detecting and Measuring the Diameters of Solid and Transparent Objects , 2016, IEEE Sensors Journal.

[17]  Li Li,et al.  Laser-induced damages to charge coupled device detector using a high-repetition-rate and high-peak-power laser , 2013 .

[18]  Zhenqiang Yao,et al.  An experimental investigation of underwater pulsed laser forming , 2014 .

[19]  J. Fraser,et al.  An extrinsic silicon charge coupled device for detecting infrared radiation , 1974 .

[20]  R. D. Poshusta Error Analysis , 2019, Numerical Methods.

[21]  J. H. Wilkinson,et al.  Error analysis , 2003 .

[22]  Ruzairi Abdul Rahim,et al.  Optical tomography sensor configuration using two orthogonal and two rectilinear projection arrays , 2005 .

[23]  Masturah Tunnur Mohamad Talib,et al.  Simulation of Invasive Ultrasonic Tomography for Three Phase Mixture , 2018 .

[24]  M. Chaudhry,et al.  Radiation exposure and privacy concerns surrounding full-body scanners in airports , 2014 .

[25]  I. I. Rushakov,et al.  Computed Tomography , 2019, Compendium of Biomedical Instrumentation.

[26]  Guotian He,et al.  A high-speed image sensing technique with adjustable frame rate based on an ordinary CCD , 2008 .

[27]  A. Choudhury Object appearance and colour , 2014 .