Towards Precise Interpretation of Oil Transformers via Novel Combined Techniques Based on DGA and Partial Discharge Sensors
暂无分享,去创建一个
Matti Lehtonen | Karar Mahmoud | Sayed A. Ward | Mohamed M. F. Darwish | Adel El-Faraskoury | Mohamed Badawi | Shimaa A. Ibrahim | M. Lehtonen | S. Ward | M. Darwish | Mohamed Badawi | K. Mahmoud | Adel El-Faraskoury | S. Ibrahim
[1] Matti Lehtonen,et al. An Effective Bi-Stage Method for Renewable Energy Sources Integration into Unbalanced Distribution Systems Considering Uncertainty , 2021, Processes.
[2] Matti Lehtonen,et al. Robust Design of ANFIS-Based Blade Pitch Controller for Wind Energy Conversion Systems Against Wind Speed Fluctuations , 2021, IEEE Access.
[3] He Yigang,et al. A Deep Parallel Diagnostic Method for Transformer Dissolved Gas Analysis , 2020, Applied Sciences.
[4] Matti Lehtonen,et al. An Efficient Fuzzy-Logic Based Variable-Step Incremental Conductance MPPT Method for Grid-Connected PV Systems , 2021, IEEE Access.
[5] A. Abu-Siada,et al. A review of dissolved gas analysis measurement and interpretation techniques , 2014, IEEE Electrical Insulation Magazine.
[6] Matti Lehtonen,et al. Deep Learning-Based Industry 4.0 and Internet of Things towards Effective Energy Management for Smart Buildings , 2021, Sensors.
[7] Subham Dawn,et al. Novel prediction‐reliability based graphical DGA technique using multi‐layer perceptron network & gas ratio combination algorithm , 2019, IET Science, Measurement & Technology.
[8] Matti Lehtonen,et al. Reliable Industry 4.0 Based on Machine Learning and IoT for Analyzing, Monitoring, and Securing Smart Meters , 2021, Sensors.
[9] Ahmed Abu-Siada,et al. Improved Consistent Interpretation Approach of Fault Type within Power Transformers Using Dissolved Gas Analysis and Gene Expression Programming , 2019, Energies.
[10] Diaa-Eldin A. Mansour,et al. Development of a new graphical technique for dissolved gas analysis in power transformers based on the five combustible gases , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.
[11] Tamás Orosz,et al. Evolution and Modern Approaches of the Power Transformer Cost Optimization Methods , 2019, Period. Polytech. Electr. Eng. Comput. Sci..
[12] Ieee Standards Board. IEEE guide for the interpretation of gases generated in oil-immersed transformers , 1992 .
[13] Matti Lehtonen,et al. Enhancing Diagnostic Accuracy of Transformer Faults Using Teaching-Learning-Based Optimization , 2021, IEEE Access.
[14] Matti Lehtonen,et al. Fast Corona Discharge Assessment Using FDM integrated With Full Multigrid Method in HVDC Transmission Lines Considering Wind Impact , 2020, IEEE Access.
[15] Tao Yu,et al. Dissolved Gas Analysis Principle-Based Intelligent Approaches to Fault Diagnosis and Decision Making for Large Oil-Immersed Power Transformers: A Survey , 2018 .
[16] J. L. Guardado,et al. A Comparative Study of Neural Network Efficiency in Power Transformers Diagnosis Using Dissolved Gas Analysis , 2001, IEEE Power Engineering Review.
[18] M. Lehtonen,et al. Development of industrial scale PVC nanocomposites with comprehensive enhancement in dielectric properties , 2019, IET Science, Measurement & Technology.
[19] A. O. Akumu,et al. Power Transformer Fault Severity Estimation Based on Dissolved Gas Analysis and Energy of Fault Formation Technique , 2019, J. Electr. Comput. Eng..
[20] Xi Gongwei,et al. Study on the development and test method of SnO2-based gas sensor array for dissolved gas analysis , 2017, 2017 13th IEEE International Conference on Electronic Measurement & Instruments (ICEMI).
[21] M. Lehtonen,et al. Recent Advances in Polymer Nanocomposites Based on Polyethylene and Polyvinylchloride for Power Cables , 2020, Materials.
[22] Matti Lehtonen,et al. Assessment of an Improved Three-Diode against Modified Two-Diode Patterns of MCS Solar Cells Associated with Soft Parameter Estimation Paradigms , 2021, Applied Sciences.
[23] Sukhbir Singh,et al. Duval Triangle: A Noble Technique for DGA in Power Transformers , 2010 .
[25] Mario Manana,et al. Dissolved Gas Analysis Equipment for Online Monitoring of Transformer Oil: A Review , 2019, Sensors.
[26] Ayman Hoballah,et al. Hybrid Grey Wolf Optimizer for Transformer Fault Diagnosis Using Dissolved Gases Considering Uncertainty in Measurements , 2020, IEEE Access.
[27] Gilberto Francisco Martha de Souza,et al. Wavelet-Like Transform to Optimize the Order of an Autoregressive Neural Network Model to Predict the Dissolved Gas Concentration in Power Transformer Oil from Sensor Data , 2020, Sensors.
[28] Mamdouh Abdel-Akher,et al. Implementation of three-phase transformer model in radial load-flow analysis , 2013 .
[29] Mahmoud N. Ali,et al. Promising MPPT Methods Combining Metaheuristic, Fuzzy-Logic and ANN Techniques for Grid-Connected Photovoltaic † , 2021, Sensors.
[30] S. A. Ward. Evaluating transformer condition using DGA oil analysis , 2003, 2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.
[31] Matti Lehtonen,et al. Optimal Harmonic Mitigation in Distribution Systems with Inverter Based Distributed Generation , 2021, Applied Sciences.
[32] Matti Lehtonen,et al. An Improved Neural Network Algorithm to Efficiently Track Various Trajectories of Robot Manipulator Arms , 2021, IEEE Access.
[33] V. Miranda,et al. Diagnosing Faults in Power Transformers With Autoassociative Neural Networks and Mean Shift , 2012, IEEE Transactions on Power Delivery.
[34] Xiaohui Yang,et al. Bio-Inspired PHM Model for Diagnostics of Faults in Power Transformers Using Dissolved Gas-in-Oil Data , 2019, Sensors.
[35] Sherif S. M. Ghoneim,et al. Dissolved Gas Analysis as a Diagnostic Tools for Early Detection of Transformer Faults , 2012 .
[36] Maria Isabel Ribeiro,et al. Gaussian Probability Density Functions: Properties and Error Characterization , 2004 .
[37] Nagy I. Elkalashy,et al. Conditional probability-based interpretation of dissolved gas analysis for transformer incipient faults , 2017 .
[38] M. Lehtonen,et al. Impact of Nanoparticles Functionalization on Partial Discharge Activity within PVC/SiO2 Nanocomposites , 2018, 2018 IEEE 2nd International Conference on Dielectrics (ICD).
[39] M. Rafiq,et al. Use of vegetable oils as transformer oils – a review , 2015 .
[40] Matti Lehtonen,et al. Optimal Estimation of Proton Exchange Membrane Fuel Cells Parameter Based on Coyote Optimization Algorithm , 2021, Applied Sciences.
[41] Jawad Faiz,et al. Dissolved gas analysis evaluation in electric power transformers using conventional methods a review , 2017, IEEE Transactions on Dielectrics and Electrical Insulation.
[43] M. Lehtonen,et al. Experimental measurements of partial discharge activity within LDPE/TiO2 nanocomposites , 2017, 2017 Nineteenth International Middle East Power Systems Conference (MEPCON).
[44] Laurent Lamarre,et al. The duval pentagon-a new complementary tool for the interpretation of dissolved gas analysis in transformers , 2014, IEEE Electrical Insulation Magazine.
[45] Osama E. Gouda,et al. Condition assessment of power transformers based on dissolved gas analysis , 2019 .