Spatial Filtering Improves EMG Classification Accuracy Following Targeted Muscle Reinnervation

The combination of targeted muscle reinnervation (TMR) and pattern classification of electromyography (EMG) has shown great promise for multifunctional myoelectric prosthesis control. In this study, we hypothesized that surface EMG recordings with high spatial resolution over reinnervated muscles could capture focal muscle activity and improve the classification accuracy of identifying intended movements. To test this hypothesis, TMR subjects with transhumeral or shoulder disarticulation amputations were recruited. Spatial filters such as single differential filters, double differential filters, and various two-dimensional, high-order spatial filters were used, and the classification accuracies for fifteen different movements were calculated. Compared with monopolar recordings, spatially localized EMG signals produced increased accuracy in identifying the TMR patients’ movement intents, especially for hand movements. When the number of EMG signals was constrained to 12, the double differential filters gave 5–15% higher classification accuracies than the filters with lower spatial resolution, but resulted in comparable accuracies to the filters with higher spatial resolution. These results suggest that double differential EMG recordings may further improve the TMR-based neural interface for robust, multifunctional control of artificial arms.

[1]  J. G. van Dijk,et al.  A convenient method to reduce crosstalk in surface EMG. Cobb Award-winning article, 2001. , 2001, Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology.

[2]  J. G. Dijk,et al.  A convenient method to reduce crosstalk in surface EMG , 2001, Clinical Neurophysiology.

[3]  Levi J. Hargrove,et al.  A Comparison of Surface and Intramuscular Myoelectric Signal Classification , 2007, IEEE Transactions on Biomedical Engineering.

[4]  He Huang,et al.  A Strategy for Identifying Locomotion Modes Using Surface Electromyography , 2009, IEEE Transactions on Biomedical Engineering.

[5]  Todd A. Kuiken,et al.  The hyper-reinnervation of rat skeletal muscle , 1995, Brain Research.

[6]  L. Batehup,et al.  A new strategy. , 1992, Nursing times.

[7]  He Huang,et al.  An Analysis of EMG Electrode Configuration for Targeted Muscle Reinnervation Based Neural Machine Interface , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[8]  Robert D. Lipschutz,et al.  The use of targeted muscle reinnervation for improved myoelectric prosthesis control in a bilateral shoulder disarticulation amputee , 2004, Prosthetics and orthotics international.

[9]  R.N. Scott,et al.  A new strategy for multifunction myoelectric control , 1993, IEEE Transactions on Biomedical Engineering.

[10]  K. Englehart,et al.  Classification of the myoelectric signal using time-frequency based representations. , 1999, Medical engineering & physics.

[11]  C. Disselhorst-Klug,et al.  Improvement of spatial resolution in surface-EMG: a theoretical and experimental comparison of different spatial filters , 1997, IEEE Transactions on Biomedical Engineering.

[12]  Kevin B. Englehart,et al.  A robust, real-time control scheme for multifunction myoelectric control , 2003, IEEE Transactions on Biomedical Engineering.

[13]  Richard F. Weir,et al.  A Comparison of the Effects of Electrode Implantation and Targeting on Pattern Classification Accuracy for Prosthesis Control , 2008, IEEE Transactions on Biomedical Engineering.

[14]  B Hudgins,et al.  Myoelectric signal processing for control of powered limb prostheses. , 2006, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[15]  T W Williams,et al.  Practical methods for controlling powered upper-extremity prostheses. , 1990, Assistive technology : the official journal of RESNA.

[16]  D Graupe,et al.  Multifunctional prosthesis and orthosis control via microcomputer identification of temporal pattern differences in single-site myoelectric signals. , 1982, Journal of biomedical engineering.

[17]  Ping Zhou,et al.  Decoding a new neural machine interface for control of artificial limbs. , 2007, Journal of neurophysiology.

[18]  Robert D. Lipschutz,et al.  Improved Myoelectric Prosthesis Control Accomplished Using Multiple Nerve Transfers , 2006, Plastic and reconstructive surgery.

[19]  David G. Stork,et al.  Pattern Classification , 1973 .

[20]  Dario Farina,et al.  Concentric-ring electrode systems for noninvasive detection of single motor unit activity , 2001, IEEE Transactions on Biomedical Engineering.

[21]  G. E. Loeb,et al.  Implantable electrical and mechanical interfaces with nerve and muscle , 2006, Annals of Biomedical Engineering.

[22]  Robert D. Lipschutz,et al.  Targeted reinnervation for enhanced prosthetic arm function in a woman with a proximal amputation: a case study , 2007, The Lancet.

[23]  J. Basmajian Muscles Alive—their functions revealed by electromyography , 1963 .