Peripheral Prism Glasses: Effects of Dominance, Suppression, and Background

Purpose. Unilateral peripheral prisms for homonymous hemianopia (HH) place different images on corresponding peripheral retinal points, a rivalrous situation in which local suppression of the prism image could occur and thus limit device functionality. Detection with peripheral prisms has primarily been evaluated using conventional perimetry, where binocular rivalry is unlikely to occur. We quantified detection over more visually complex backgrounds and examined the effects of ocular dominance. Methods. Detection rates of eight participants with HH or quadranopia and normal binocularity wearing unilateral peripheral prism glasses were determined for static perimetry targets briefly presented in the prism expansion area (in the blind hemifield) and the seeing hemifield, under monocular and binocular viewing, over uniform gray and more complex patterned backgrounds. Results. Participants with normal binocularity had mixed sensory ocular dominance, demonstrated no difference in detection rates when prisms were fitted on the side of the HH or the opposite side (p > 0.2), and had detection rates in the expansion area that were not different for monocular and binocular viewing over both backgrounds (p > 0.4). However, two participants with abnormal binocularity and strong ocular dominance demonstrated reduced detection in the expansion area when prisms were fitted in front of the non-dominant eye. Conclusions. We found little evidence of local suppression of the peripheral prism image for HH patients with normal binocularity. However, in cases of strong ocular dominance, consideration should be given to fitting prisms before the dominant eye. Although these results are promising, further testing in more realistic conditions including image motion is needed.

[1]  R. Blake,et al.  Spatial zones of binocular rivalry in central and peripheral vision , 1992, Visual Neuroscience.

[2]  Roy G. Cole Od Faao Remediation and Management of Low Vision , 1996 .

[3]  Gang Luo,et al.  Object detection in the ring scotoma of a monocular bioptic telescope. , 2011, Archives of ophthalmology.

[4]  Milton Katz,et al.  Contrast sensitivity through hybrid diffractive, Fresnel, and refractive prisms. , 2004, Optometry.

[5]  K. Daum CLINICAL USES OF PRISM: A SPECTRUM OF APPLICATIONS , 1996 .

[6]  N. Newman,et al.  Homonymous hemianopias: clinical-anatomic correlations in 904 cases. , 2006, Neurology.

[7]  D J Field,et al.  Relations between the statistics of natural images and the response properties of cortical cells. , 1987, Journal of the Optical Society of America. A, Optics and image science.

[8]  Eli Peli,et al.  DLP-based dichoptic vision test system. , 2010, Journal of biomedical optics.

[9]  Eli Peli,et al.  The Optical Functional Advantages of an Intraocular Low-Vision Telescope , 2002, Optometry and vision science : official publication of the American Academy of Optometry.

[10]  K. Pearson On the Theory of Contingency and Its Relation to Association and Normal Correlation , 2013 .

[11]  Robert L. Mason,et al.  Statistical Principles in Experimental Design , 2003 .

[12]  E. Peli,et al.  Clinical and Laboratory Evaluation of Peripheral Prism Glasses for Hemianopia , 2009, Optometry and vision science : official publication of the American Academy of Optometry.

[13]  S. Folstein,et al.  "Mini-mental state". A practical method for grading the cognitive state of patients for the clinician. , 1975, Journal of psychiatric research.

[14]  Robert F Hess,et al.  Quantifying sensory eye dominance in the normal visual system: a new technique and insights into variation across traditional tests. , 2010, Investigative ophthalmology & visual science.

[15]  Mary Warren,et al.  Pilot study on activities of daily living limitations in adults with hemianopsia. , 2009, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[16]  J E Keeffe,et al.  Impact of unilateral and bilateral vision loss on quality of life , 2005, British Journal of Ophthalmology.

[17]  Eli Peli,et al.  Community-based trial of a peripheral prism visual field expansion device for hemianopia. , 2008, Archives of ophthalmology.

[18]  E. Peli OPTOMETRY AND VISION SCIENCE Copyright © 2000 American Academy of Optometry ORIGINAL ARTICLE Field Expansion for Homonymous Hemianopia by Optically Induced Peripheral Exotropia , 2022 .

[19]  Hiroshi Uozato,et al.  Quantitative measurement of ocular dominance using binocular rivalry induced by retinometers , 2006, Journal of cataract and refractive surgery.

[20]  R. Blake © 2001 Kluwer Academic Publishers. Printed in the Netherlands. 5 A Primer on Binocular Rivalry, Including Current Controversies , 2000 .

[21]  Alex R. Bowers,et al.  Consideration of Optical Scotomas in Designing Visual Field Expansion Devices , 2009 .

[22]  T. Schenkenberg,et al.  Line bisection and unilateral visual neglect in patients with neurologic impairment , 1980, Neurology.

[23]  Elena Piedrahita,et al.  Ocular dominance diagnosis and its influence in monovision. , 2007, American journal of ophthalmology.

[24]  L. Gauthier,et al.  The Bells Test: A quantitative and qualitative test for visual neglect. , 1989 .

[25]  Ann Plotkin,et al.  REMEDIATION AND MANAGEMENT OF LOW VISION , 1996 .

[26]  J M Cohen,et al.  An overview of enhancement techniques for peripheral field loss. , 1993, Journal of the American Optometric Association.

[27]  Jon Currie,et al.  Homonymous Visual Field Defects and Stroke in an Older Population , 2002, Stroke.

[28]  C. A. Young HOMONYMOUS HEMIANOPSIA DURING PREGNANCY AIDED BY REFLECTING PRISM , 1929 .

[29]  E. O'Neill,et al.  Prism Therapy and Visual Rehabilitation in Homonymous Visual Field Loss , 2011, Optometry and vision science : official publication of the American Academy of Optometry.

[30]  Cohen Jm,et al.  An overview of enhancement techniques for peripheral field loss. , 1993 .