A compliant aortic model for in vitro simulations: Design and manufacturing process.

We design and manufacture a silicone model of the human aorta, able to mimic both the geometrical and the mechanical properties of physiological individuals, with a specific focus on reproducing the compliance. In fact, while the models available in the literature exhibit an unrealistic compliant behavior, though they are detailed from the geometrical viewpoint, here the goal is to provide an accurate compliant tool for in vitro testing the devices that interface with the vascular system. A parametric design of the aortic model is obtained based on the available literature data, and the model is manufactured with a specific silicone mixture using rapid prototyping and molding techniques. The manufactured prototype has been tested by means of computed tomography scans for evaluating the matching of the mechanical properties with the desired ones. Results show a high degree of adherence between the imposed and the measured compliance values for each main aortic section. Thus, our work proves the feasibility of the approach, and the possibility to manufacture compliant models that reproduce the mechanical behavior of the aorta for in vitro studies.

[1]  S. Moebus,et al.  Body-surface adjusted aortic reference diameters for improved identification of patients with thoracic aortic aneurysms: results from the population-based Heinz Nixdorf Recall study. , 2013, International journal of cardiology.

[2]  A. Yoganathan,et al.  Mitral Valve Function and Chordal Force Distribution Using a Flexible Annulus Model: An In Vitro Study , 2005, Annals of Biomedical Engineering.

[3]  Jeffrey R. Gohean,et al.  Comparative in vitro study of bileaflet and tilting disk valve behavior in the pulmonary position. , 2006, Journal of biomechanical engineering.

[4]  Razvan Udroiu,et al.  Experimental determination of surface roughness of parts obtained by rapid prototyping , 2009 .

[5]  M. Kalējs,et al.  Rapid prototyping of compliant human aortic roots for assessment of valved stents. , 2009, Interactive cardiovascular and thoracic surgery.

[6]  M. Walsh,et al.  Experimental modelling of aortic aneurysms: novel applications of silicone rubbers. , 2009, Medical engineering & physics.

[7]  M. Viergever,et al.  Aortic pulsatile distention in young healthy volunteers is asymmetric: analysis with ECG-gated MRI. , 2009, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[8]  Guido Gerig,et al.  User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability , 2006, NeuroImage.

[9]  Ettore Lanzarone,et al.  A new pulsatile volumetric device with biomorphic valves for the in vitro study of the cardiovascular system. , 2009, Artificial organs.

[10]  P. Holt,et al.  Morphology of Aortic Arch Pathology: Implications for Endovascular Repair , 2010, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[11]  Bingheng Lu,et al.  Rapid prototyping assisted surgery planning and custom implant design , 2009 .

[12]  David A. Vorp,et al.  An Experimental and Numerical Comparison of the Rupture Locations of an Abdominal Aortic Aneurysm , 2009, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[13]  Fabian Rengier,et al.  Heartbeat-related distension and displacement of the thoracic aorta in healthy volunteers. , 2012, European journal of radiology.

[14]  L. Boussel,et al.  In vitro non-rigid life-size model of aortic arch aneurysm for endovascular prosthesis assessment. , 2008, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[15]  G. Biglino,et al.  Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing , 2013, Journal of Cardiovascular Magnetic Resonance.

[16]  D. Vorp,et al.  3D reconstruction and manufacture of real abdominal aortic aneurysms: from CT scan to silicone model. , 2008, Journal of biomechanical engineering.

[17]  T. Dohi,et al.  Nonsymmetric leaflet motion of St. Jude Medical mitral valves simulated with a computer-controlled hydraulic mock circulator. , 2008, Artificial organs.

[18]  D. F. Young,et al.  Computer simulation of arterial flow with applications to arterial and aortic stenoses. , 1992, Journal of biomechanics.

[19]  B. Yoffe,et al.  Experimental study of a novel suture-less aortic anastomotic device. , 2007, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[20]  Ferdinando Auricchio,et al.  From CT scanning to 3-D printing technology for the preoperative planning in laparoscopic splenectomy , 2015, Surgical Endoscopy.

[21]  J. Giannatsis,et al.  Additive fabrication technologies applied to medicine and health care: a review , 2009 .

[22]  Gianfranco Beniamino Fiore,et al.  Response to the Letter to the Editor: A New Pulsatile Volumetric Device With Biomorphic Valves for the In Vitro Study of the Cardiovascular System by M.B. Munir et al. , 2011 .

[23]  Ferdinando Auricchio,et al.  A Regression Method Based on Noninvasive Clinical Data to Predict the Mechanical Behavior of Ascending Aorta Aneurysmal Tissue , 2017, IEEE Transactions on Biomedical Engineering.

[24]  Fabrizio Ruggeri,et al.  Inertance estimation in a lumped-parameter hydraulic simulator of human circulation. , 2013, Journal of biomechanical engineering.

[25]  M. C. Tracey,et al.  Mechanical characterization of bulk Sylgard 184 for microfluidics and microengineering , 2014 .

[26]  Danial Shahmirzadi,et al.  3D-Printed Tissue-Mimicking Phantoms for Medical Imaging and Computational Validation Applications. , 2014, 3D printing and additive manufacturing.

[27]  Ajit P Yoganathan,et al.  The material properties of the native porcine mitral valve chordae tendineae: an in vitro investigation. , 2006, Journal of biomechanics.

[28]  T. Bisdas,et al.  Future perspectives for the role of 3D rapid prototyping aortic biomodels in vascular medicine. , 2011, VASA. Zeitschrift fur Gefasskrankheiten.

[29]  Ferdinando Auricchio,et al.  Value of 3D printing for the comprehension of surgical anatomy , 2017, Surgical Endoscopy.

[30]  Masayuki Fukuzawa,et al.  Simulative operation on congenital heart disease using rubber-like urethane stereolithographic biomodels based on 3D datasets of multislice computed tomography. , 2009, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[31]  P. Walker,et al.  The influence of ventricular input impedance on the hydrodynamic performance of bioprosthetic aortic roots in vitro. , 2001, The Journal of heart valve disease.

[32]  R. Mohiaddin,et al.  Regional aortic compliance studied by magnetic resonance imaging: the effects of age, training, and coronary artery disease. , 1989, British heart journal.

[33]  K Torres,et al.  Application of rapid prototyping techniques for modelling of anatomical structures in medical training and education. , 2011, Folia morphologica.

[34]  R. Figliola,et al.  In vitro study of flow regulation for pulmonary insufficiency. , 2007, Journal of biomechanical engineering.

[35]  Paul G M Knoops,et al.  A Mock Circulatory System Incorporating a Compliant 3D‐Printed Anatomical Model to Investigate Pulmonary Hemodynamics , 2017, Artificial organs.

[36]  Hans-Peter Meinzer,et al.  Physical models aiding in complex congenital heart surgery. , 2008, The Annals of thoracic surgery.