Sensitivity of the OLGA and VCM models to erroneous marker placement: effects on 3D-gait kinematics.

Gait data need to be reliable to be valuable for clinical decision-making. To reduce the impact of marker placement errors, the Optimized Lower Limb Gait Analysis (OLGA) model was developed. The purpose of this study was to assess the sensitivity of the kinematic gait data to a standard marker displacement of the OLGA model compared with the standard Vicon Clinical Manager (VCM) model and to determine whether OLGA reduces the errors due to the most critical marker displacements. Healthy adults performed six gait sessions. The first session was a standard gait session. For the following sessions, 10mm marker displacements were applied. Kinematic data were collected for both models. The root mean squares of the differences (RMS) were calculated for the kinematics of the displacement sessions with respect to the first session. The results showed that the RMS values were generally larger than the stride-to-stride variation except for the pelvic kinematics. For the ankle, knee and hip kinematics, OLGA significantly reduced the averaged RMS values for most planes. The shank, knee and thigh anterior-posterior marker displacements resulted in RMS values exceeding 10°. OLGA reduced the errors due to the knee and thigh marker displacements, but not the errors due to the ankle marker displacements. In conclusion, OLGA reduces the effect of erroneous marker placement, but does not fully compensate all effects, indicating that accurate marker placement remains of crucial importance for adequate 3D-gait analysis and subsequent clinical decision-making.

[1]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 2: instrumental errors. , 2004, Gait & posture.

[2]  R. B. Davis,et al.  A gait analysis data collection and reduction technique , 1991 .

[3]  M. Schwartz,et al.  A new method for estimating joint parameters from motion data. , 2004, Journal of biomechanics.

[4]  E. Zwick,et al.  Intrasubject repeatability of gait analysis data in normal and spastic children. , 2000, Clinical biomechanics.

[5]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artifact assessment and compensation. , 2005, Gait & posture.

[6]  A. Cappozzo,et al.  Pelvis and lower limb anatomical landmark calibration precision and its propagation to bone geometry and joint angles , 1999, Medical & Biological Engineering & Computing.

[7]  H. K. Ramakrishnan,et al.  Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait , 1989, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[8]  I. Charlton,et al.  Repeatability of an optimised lower body model. , 2004, Gait & posture.

[9]  M. Morris,et al.  The reliability of three-dimensional kinematic gait measurements: a systematic review. , 2009, Gait & posture.

[10]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 1: theoretical background. , 2005, Gait & posture.

[11]  M P Kadaba,et al.  Measurement of lower extremity kinematics during level walking , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[12]  Henk J Stam,et al.  Repeatability and variation of quantitative gait data in subgroups of patients with stroke. , 2008, Gait & posture.

[13]  S. Walt,et al.  Reliability of upper and lower limb three-dimensional kinematics in children with hemiplegia. , 2005, Gait & posture.

[14]  George E Gorton,et al.  Assessment of the kinematic variability among 12 motion analysis laboratories. , 2009, Gait & posture.

[15]  Suzanne Halliday,et al.  Interobserver Variability of Gait Analysis in Patients With Cerebral Palsy , 2003, Journal of pediatric orthopedics.

[16]  Joyce P Trost,et al.  Measurement and management of errors in quantitative gait data. , 2004, Gait & posture.

[17]  Henk J Stam,et al.  Repeatability of lower limb three-dimensional kinematics in patients with stroke. , 2008, Gait & posture.

[18]  Lorenzo Chiari,et al.  Human movement analysis using stereophotogrammetry. Part 4: assessment of anatomical landmark misplacement and its effects on joint kinematics. , 2005, Gait & posture.

[19]  A Leardini,et al.  Position and orientation in space of bones during movement: experimental artefacts. , 1996, Clinical biomechanics.