Using computational simulation to aid in the prediction of socket fit: a preliminary study.
暂无分享,去创建一个
[1] D S Childress,et al. Generic, geometric finite element analysis of the transtibial residual limb and prosthetic socket. , 1997, Journal of rehabilitation research and development.
[2] B. Persson,et al. Measurement of maximal end-weight-bearing in lower limb amputees , 1982, Prosthetics and orthotics international.
[3] M Zhang,et al. Finite element modelling of a residual lower-limb in a prosthetic socket: a survey of the development in the first decade. , 1998, Medical engineering & physics.
[4] D. Childress,et al. Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: comparison of finite element results with experimental measurements. , 1993, Journal of rehabilitation research and development.
[5] W. Neumann,et al. Effects of Nondirective Suggestions on Pain Tolerance, Pain Threshold and Pain Intensity Perception , 1997, Perceptual and motor skills.
[6] M. Zhang,et al. Comparison of computational analysis with clinical measurement of stresses on below-knee residual limb in a prosthetic socket. , 2000, Medical engineering & physics.
[7] V. C. Roberts,et al. Development of a non-linear finite element modelling of the below-knee prosthetic socket interface. , 1995, Medical engineering & physics.
[8] T. Jensen,et al. Immediate and long-term phantom limb pain in amputees: Incidence, clinical characteristics and relationship to pre-amputation limb pain , 1985, Pain.
[9] Ming Zhang,et al. Finite-element analysis to determine effect of monolimb flexibility on structural strength and interaction between residual limb and prosthetic socket. , 2004, Journal of rehabilitation research and development.
[10] M. Maclachlan,et al. Phantom limb pain and residual limb pain following lower limb amputation: a descriptive analysis. , 2001, Disability and rehabilitation.
[11] Gisèle Pickering,et al. Impact of Age, Gender and Cognitive Functioning on Pain Perception , 2002, Gerontology.
[12] D S Childress,et al. Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with trans-tibial amputation. , 1996, Journal of rehabilitation research and development.
[13] Edward S. Neumann,et al. Measurement of Socket Discomfort—Part I: Pressure Sensation , 2001 .
[14] Xiaohong Jia,et al. Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket. , 2004, Medical engineering & physics.
[15] H B Skinner,et al. The relationship between gait parameters and pain in persons with transtibial amputation: a preliminary report. , 1998, Journal of rehabilitation research and development.
[16] Fischer Aa,et al. Pressure tolerance over muscles and bones in normal subjects. , 1986 .
[17] Jocelyne Bédard,et al. New-York, 1985 , 2005 .
[18] Dr D. P. Reynolds,et al. Interface load analysis for computer-aided design of below-knee prosthetic sockets , 1992, Medical and Biological Engineering and Computing.
[19] R W Davis,et al. Phantom sensation, phantom pain, and stump pain. , 1993, Archives of physical medicine and rehabilitation.
[20] J C H Goh,et al. Development of an integrated CAD-FEA process for below-knee prosthetic sockets. , 2005, Clinical biomechanics.
[21] R L Lieber,et al. Volume changes occurring in postoperative below-knee residual limbs. , 1988, Journal of rehabilitation research and development.
[22] A W Buis,et al. Conventional patellar-tendon-bearing (PTB) socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a transtibial amputee , 1998, Prosthetics and orthotics international.
[23] J. Sanders,et al. Thermal response of skin to cyclic pressure and pressure with shear: a technical note. , 2000, Journal of rehabilitation research and development.
[24] James M. Margolis,et al. Engineering Thermoplastics: Properties and Applications , 1985 .
[25] A. Mak,et al. In vivo friction properties of human skin , 1999, Prosthetics and orthotics international.
[26] A. Mak,et al. Regional differences in pain threshold and tolerance of the transtibial residual limb: including the effects of age and interface material. , 2005, Archives of physical medicine and rehabilitation.