The fundamental mechanisms of heat and mass transfer as well as of two-phase flow in compact condensers are not well understood. In this experimental investigation a single sub-channel of a compact plate heat exchanger is simulated by using a small diameter inclined aluminium tube. The inner diameter of the tube is 7 mm and the length is 500 mm. Film thicknesses and flooding points during reflux condensation of steam in this tube are determined by using an ultrasonic technique. Measurements are carried out with a 15 MHz ultrasonic transducer attached to the outer tube wall. The emitted ultrasonic signal is reflected at each interface. The condensate film thickness can be determined by measuring the time difference between the reflections of the signal at the inner tube wall and at the liquid-vapour interface. The results for the liquid film thickness obtained by the pulse-echo technique are compared with those obtained by a needle-probe technique. As the measured film thicknesses were found to be in good agreement, the accuracy of the pulse-echo technique could be verified. The results demonstrate that the ultrasonic pulse-echo technique offers a feasible alternative for two-phase flow applications. With the pulse-echo technique the thickness of the condensate film was measured at the lowermost point of the tube. The film thickness measurements were carried out before the onset of flooding at inclination angles of 30, 60 and 90° to the horizontal. It was found that the inclination angle has only a minor effect on the film thickness. Shear stress and surface tension have in small diameter tubes apparently a more obvious effect than the gravitational force. The flooding experiments are carried out at a pressure of 10kPa and at inclination angles of 30, 60 and 90° to the horizontal. The results show that the inclination angle has no significant effect on the onset of flooding in the small diameter tube. A modified form of a flooding correlation proposed by McQuillan and Whalley is presented. This correlation predicts well the experimental data.
[1]
Yehuda Taitel,et al.
Flooding in inclined pipes — Effect of entrance section
,
1986
.
[2]
Schoenfeld Pd,et al.
Flooding during reflux condensation of steam in an inclined elliptical tube.
,
2000
.
[3]
Xiaoze Du,et al.
Study on laminar film-wise condensation for vapor flow in an inclined small/mini-diameter tube
,
2000
.
[4]
P. B. Whalley,et al.
A comparison between flooding correlations and experimental flooding data for gas-liquid flow in vertical circular tubes
,
1985
.
[5]
Somchai Wongwises,et al.
Effect of inclination angles and upper end conditions on the countercurrent flow limitation in straight circular pipes
,
1998
.
[6]
N. V. Suryanarayana,et al.
Film thickness measurement with an ultrasonic transducer
,
1993
.
[7]
Geoffrey F. Hewitt,et al.
Theoretical investigation of the diameter effect on flooding in countercurrent flow
,
1996
.
[8]
Jen-Shih Chang,et al.
Determination of two-phase interfacial areas by an ultrasonic technique
,
1990
.