A study of mass transfer in the membrane air-stripping process using microporous polyproplylene hollow fibers

Abstract The mass transfer of water and chloroform in membrane air-stripping (MAS) was studied using a microporous polypropylene hollow fiber membrane module, with air flow on the lumen side and liquid cross-flow on the shell side. Water transport experiments showed that its mass transport decreased significantly when the membrane had been in contact with water for prolonged periods. It was hypothesized that the increased mass transfer resistance was due to water condensation in a fraction of the membrane pores. MAS of chloroform from aqueous solutions confirmed the additional mass transfer resistance with prior exposure to water. It was concluded that membrane pores were either completely air-filled or partially wetted with water during the MAS process. Existing models are able to predict the performance only for either completely air-filled or liquid-filled pores. A modified model was proposed to take into account the diffusion through partially wetted pores. The model described the data well. This hypothesis also provided a plausible explanation to the conflicting literature values of the membrane mass transfer resistance. It was found that the membrane mass transfer resistance of the partially wetted pores is two orders of magnitude higher than that of air-filled pores. The overall mass transfer coefficient was constant for initial feed chloroform concentrations ranging from 50 to 1000 ppm.

[1]  Amy K. Zander,et al.  Removing VOCs by Membrane Stripping , 1989 .

[2]  C. Wilke,et al.  Correlation of diffusion coefficients in dilute solutions , 1955 .

[3]  K. Sirkar,et al.  Dispersion‐free solvent extraction with microporous hollow‐fiber modules , 1988 .

[4]  G. M. Watson,et al.  Gaseous Diffusion in Porous Media at Uniform Pressure , 1961 .

[5]  J. Keurentjes,et al.  Hydrophobicity measurements of microfiltration and ultrafiltration membranes. , 1989 .

[6]  T. Matsuura,et al.  Membrane Air Stripping: A Process for Removal of Organics from Aqueous Solutions , 1998 .

[7]  M. Semmens,et al.  Batch studies on a closed loop air stripping process , 1994 .

[8]  Edward L Cussler,et al.  Microporous hollow fibers for gas absorption : II. Mass transfer across the membrane , 1985 .

[9]  P. Plucinski,et al.  Mass transfer in the shell side of cross flow hollow fiber modules , 1998 .

[10]  James M. Montgomery,et al.  Water Treatment Principles and Design , 1985 .

[11]  M. Semmens,et al.  Chapter 10 Membrane contactors , 1995 .

[12]  K. Sirkar,et al.  Solvent extraction with immobilized interfaces in a microporous hydrophobic membrane , 1984 .

[13]  Bhavani Raghuraman,et al.  Demulsification of water/oil/solid emulsions by hollow‐fiber membranes , 1996 .

[14]  J. Bersillon,et al.  Bubble-free aeration using membranes: mass transfer analysis , 1989 .

[15]  D. Katz,et al.  Fluid Dynamics and Heat Transfer , 1959 .

[16]  Amy K. Zander,et al.  Using a microporous hollow-fiber membrane to separate VOCs from water , 1989 .

[17]  Kang Li,et al.  Modeling of Microporous Hollow Fiber Membrane Modules Operated under Partially Wetted Conditions , 1997 .

[18]  Ming-Chien Yang,et al.  Designing hollow‐fiber contactors , 1986 .

[19]  Edward L Cussler,et al.  Microporous hollow fibers for gas absorption. I. Mass transfer in the liquid , 1985 .

[20]  D. L. Haynes,et al.  Prediction of the volatilization rates of high-volatility chemicals from natural water bodies , 1980 .

[21]  Frank Kreith,et al.  Basic heat transfer , 1980 .

[22]  Geert Versteeg,et al.  Determination of mass transfer rates in wetted and non-wetted microporous membranes , 1993 .

[23]  Edward L Cussler,et al.  Hollow fiber gas membranes , 1985 .

[24]  J. Giddings,et al.  NEW METHOD FOR PREDICTION OF BINARY GAS-PHASE DIFFUSION COEFFICIENTS , 1966 .

[25]  B. D. Miller,et al.  Large-scale application of membrane contactors for gas transfer from or to ultrapure water , 1998 .

[26]  W. G. Pollard,et al.  On Gaseous Self-Diffusion in Long Capillary Tubes , 1948 .

[27]  P. Roberts,et al.  Mass transfer of volatile organic contaminants from aqueous solution to the atmosphere during surface aeration. , 1983, Environmental science & technology.