Uniformity analysis at MEA and stack Levels for a Nexa PEM fuel cell system

Abstract The Nexa™ power module is evaluated at membrane-electrode-assembly (MEA) and stack levels. The I–V Curves of the Nexa™ PEM fuel cell system is measured using periodic current interruption to maintain isothermal stack temperature. The uniformity analysis is mainly performed on the load of 800 W for all MEAs in 10 individual Nexa™ stacks. Statistical data show that the MEA voltage without an external load averages 224 mV higher than that with a load of 800 W. The MEA voltage difference is especially pronounced around the two cells at the air compressor side. The average difference is 8.8% and the highest difference is 13.1% between the minimum MEA voltage in the stack and the mean value. This voltage difference reveals a possibility to increase the product power capability and cut the cost per kilowatts by improving the weak performance electrodes or MEAs in the stack.