Combining two‐dimensional spatially selective RF excitation, parallel imaging, and UNFOLD for accelerated MR thermometry imaging

MR thermometry can be a very challenging application, as good resolution may be needed along spatial, temporal, and temperature axes. Given that the heated foci produced during thermal therapies are typically much smaller than the anatomy being imaged, much of the imaged field‐of‐view is not actually being heated and may not require temperature monitoring. In this work, many‐fold improvements were obtained in terms of temporal resolution and/or 3D spatial coverage by sacrificing some of the in‐plane spatial coverage. To do so, three fast‐imaging approaches were jointly implemented with a spoiled gradient echo sequence: (1) two‐dimensional spatially selective RF excitation, (2) unaliasing by Fourier encoding the overlaps using the temporal dimension (UNFOLD), and (3) parallel imaging. The sequence was tested during experiments with focused ultrasound heating in ex vivo tissue and a tissue‐mimicking phantom. Temperature maps were estimated from phase‐difference images based on the water proton resonance frequency shift. Results were compared to those obtained from a spoiled gradient echo sequence sequence, using a t‐test. Temporal resolution was increased by 24‐fold, with temperature uncertainty less than 1°C, while maintaining accurate temperature measurements (mean difference between measurements, as observed in gel = 0.1°C ± 0.6; R = 0.98; P > 0.05). Magn Reson Med 66:112–122, 2011. © 2011 Wiley‐Liss, Inc.

[1]  Bruno Madore,et al.  UNFOLD‐SENSE: A parallel MRI method with self‐calibration and artifact suppression , 2004, Magnetic resonance in medicine.

[2]  Jing Yuan,et al.  Spatially varying fat‐water excitation using short 2DRF pulses , 2010, Magnetic resonance in medicine.

[3]  W. Hull,et al.  A 1H‐NMR method for determining temperature in cell culture perfusion systems , 1993, Magnetic resonance in medicine.

[4]  Bruno Quesson,et al.  Real‐time MR temperature mapping of rabbit liver in vivo during thermal ablation , 2003, Magnetic resonance in medicine.

[5]  Klaus Scheffler,et al.  Fast frequency mapping with balanced SSFP: Theory and application to proton‐resonance frequency shift thermometry , 2004, Magnetic resonance in medicine.

[6]  J A de Zwart,et al.  Fast lipid‐suppressed MR temperature mapping with echo‐shifted gradient‐echo imaging and spectral‐spatial excitation , 1999, Magnetic resonance in medicine.

[7]  P. Roemer,et al.  Noise correlations in data simultaneously acquired from multiple surface coil arrays , 1990, Magnetic resonance in medicine.

[8]  J P Felmlee,et al.  MR guided focused ultrasound: technical acceptance measures for a clinical system , 2006, Physics in medicine and biology.

[9]  J. Hindman,et al.  Proton Resonance Shift of Water in the Gas and Liquid States , 1966 .

[10]  N J Pelc,et al.  Unaliasing by Fourier‐encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI , 1999, Magnetic resonance in medicine.

[11]  Johnpauly A k-Space Analysis of Small-Tip-Angle Excitation , 2012 .

[12]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[13]  Bruno Quesson,et al.  Stability of real‐time MR temperature mapping in healthy and diseased human liver , 2004, Journal of magnetic resonance imaging : JMRI.

[14]  Juan M. Santos,et al.  Real‐time MR thermometry for monitoring HIFU ablations of the liver , 2010, Magnetic resonance in medicine.

[15]  Christopher J. Hardy,et al.  Spatial localization in two dimensions using NMR designer pulses , 1989 .

[16]  James A Bankson,et al.  Partially parallel imaging with phase‐sensitive data: Increased temporal resolution for magnetic resonance temperature imaging , 2005, Magnetic resonance in medicine.

[17]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[18]  Bruno Madore,et al.  Using UNFOLD to remove artifacts in parallel imaging and in partial‐Fourier imaging , 2002, Magnetic resonance in medicine.

[19]  Ergin Atalar,et al.  SSFP‐based MR thermometry , 2004, Magnetic resonance in medicine.

[20]  F. Jolesz,et al.  Current status and future potential of MRI‐guided focused ultrasound surgery , 2008, Journal of magnetic resonance imaging : JMRI.

[21]  K. Kuroda,et al.  A precise and fast temperature mapping using water proton chemical shift , 1995, Magnetic resonance in medicine.

[22]  K. Hynynen,et al.  Optimization of spoiled gradient‐echo phase imaging for in vivo localization of a focused ultrasound beam , 1996, Magnetic resonance in medicine.

[23]  L. Hall,et al.  Mapping of pH and temperature distribution using chemical-shift-resolved tomography , 1985 .

[24]  G H Glover,et al.  Monitoring of high‐intensity focused ultrasound‐induced temperature changes in vitro using an interleaved spiral acquisition , 2000, Magnetic resonance in medicine.

[25]  J A de Zwart,et al.  On‐line correction and visualization of motion during MRI‐controlled hyperthermia , 2001, Magnetic resonance in medicine.

[26]  Bruno Madore,et al.  Reduced field‐of‐view MRI with two‐dimensional spatially‐selective RF excitation and UNFOLD , 2005, Magnetic resonance in medicine.

[27]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[28]  Albert Macovski,et al.  A k-space analysis of small-tip-angle excitation. 1989. , 2011, Journal of magnetic resonance.

[29]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[30]  Marko Kangasniemi,et al.  Interleaved echo‐planar imaging for fast multiplanar magnetic resonance temperature imaging of ultrasound thermal ablation therapy , 2004, Journal of magnetic resonance imaging : JMRI.