Fault Detection and Location of IGBT Short-Circuit Failure in Modular Multilevel Converters

A single fault detection and location for Modular Multilevel Converter (MMC) is of great significance, as numbers of sub-modules (SMs) in MMC are connected in series. In this paper, a novel fault detection and location method is proposed for MMC in terms of the Insulated Gate Bipolar Translator (IGBT) short-circuit failure in SM. The characteristics of IGBT short-circuit failures are analyzed, based on which a Differential Comparison Low-Voltage Detection Method (DCLVDM) is proposed to detect the short-circuit fault. Lastly, the faulty IGBT is located based on the capacitor voltage of the faulty SM by Continuous Wavelet Transform (CWT). Simulations have been done in the simulation software PSCAD/EMTDC and the results confirm the validity and reliability of the proposed method.

[1]  Marc Hiller,et al.  Modulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters , 2010, IEEE Transactions on Industrial Electronics.

[2]  Zhe Chen,et al.  Fault Detection and Localization Method for Modular Multilevel Converters , 2015, IEEE Transactions on Power Electronics.

[3]  Zheng Xu,et al.  On the Bipolar MMC-HVDC Topology Suitable for Bulk Power Overhead Line Transmission: Configuration, Control, and DC Fault Analysis , 2014, IEEE Transactions on Power Delivery.

[4]  Inseok Hwang,et al.  A Survey of Fault Detection, Isolation, and Reconfiguration Methods , 2010, IEEE Transactions on Control Systems Technology.

[5]  Bin Lu,et al.  A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters , 2008, 2008 IEEE Industry Applications Society Annual Meeting.

[6]  Yu Pan-Pan,et al.  Analysis of Submodule Overcurrent Caused by DC Pole-to-pole Fault in Modular Multilevel Converter HVDC System , 2011 .

[7]  Wang Zhixin,et al.  The key technologies of VSC-MTDC and its application in China , 2016 .

[8]  Rajesh Kumar,et al.  Agent based intelligent fault detection, isolation and restoration in smart power system , 2016, 2016 IEEE Students' Conference on Electrical, Electronics and Computer Science (SCEECS).

[9]  O.P. Malik,et al.  Hybrid Traveling Wave/Boundary Protection for Monopolar HVDC Line , 2009, IEEE Transactions on Power Delivery.

[10]  Dianguo Xu,et al.  Fault Diagnosis and Tolerant Control of Single IGBT Open-Circuit Failure in Modular Multilevel Converters , 2016, IEEE Transactions on Power Electronics.

[11]  Om P. Malik,et al.  Correction to “Hybrid Traveling Wave/Boundary Protection for Monopolar HVDC Line” [Apr 09 569-578] , 2009 .

[12]  Guoqiang Wang,et al.  Key technologies of VSC-HVDC and its application on offshore wind farm in China , 2014 .

[13]  Samir Kouro,et al.  Circuit Topologies, Modeling, Control Schemes, and Applications of Modular Multilevel Converters , 2015, IEEE Transactions on Power Electronics.

[14]  Mohammad Reza Zolghadri,et al.  Fast short circuit power switch fault detection in cascaded H-bridge multilevel converter , 2013, 2013 IEEE Power & Energy Society General Meeting.

[15]  Alireza Nami,et al.  Modular Multilevel Converters for HVDC Applications: Review on Converter Cells and Functionalities , 2015, IEEE Transactions on Power Electronics.

[16]  Hossein Iman-Eini,et al.  Open-circuit fault detection and localization in Modular Multilevel Converter , 2015, The 6th Power Electronics, Drive Systems & Technologies Conference (PEDSTC2015).

[17]  R. S. Chokhawala,et al.  A discussion on IGBT short-circuit behavior and fault protection schemes , 1995 .

[18]  Alan J. Watson,et al.  Fault Detection for Modular Multilevel Converters Based on Sliding Mode Observer , 2013, IEEE Transactions on Power Electronics.

[19]  Abd Almula G. M. Gebreel,et al.  Power quality and total harmonic distortion response for MMC with increasing arm inductance based on closed loop-needless PID controller , 2016 .

[20]  E. Blackmore,et al.  Analysis of high-power IGBT short circuit failures , 2004, IEEE Transactions on Plasma Science.

[21]  A. Del Pizzo,et al.  Quick identification technique of fault conditions in cascaded H-Bridge multilevel converters , 2007, 2007 International Aegean Conference on Electrical Machines and Power Electronics.

[22]  Dawei Xiang,et al.  An Industry-Based Survey of Reliability in Power Electronic Converters , 2011, IEEE Transactions on Industry Applications.

[23]  F.Z. Peng,et al.  A smart gate drive with self-diagnosis for power MOSFETs and IGBTs , 2008, 2008 Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition.

[24]  Dong-Seok Hyun,et al.  Gate Voltage Pattern Analyze for Short-Circuit Protection in IGBT Inverters , 2007, 2007 IEEE Power Electronics Specialists Conference.

[25]  Maryam Saeedifard,et al.  Operation, Control, and Applications of the Modular Multilevel Converter: A Review , 2015, IEEE Transactions on Power Electronics.

[26]  Mario Oleskovicz,et al.  Combined solution for fault location in three-terminal lines based on wavelet transforms , 2010 .

[27]  Majid Sanaye-Pasand,et al.  A Traveling-Wave-Based Methodology for Wide-Area Fault Location in Multiterminal DC Systems , 2014, IEEE Transactions on Power Delivery.

[28]  Staffan Norrga,et al.  Dynamic Analysis of Modular Multilevel Converters , 2013, IEEE Transactions on Industrial Electronics.

[29]  Mariesa L. Crow,et al.  Fault Detection and Mitigation in Multilevel Converter STATCOMs , 2011, IEEE Transactions on Industrial Electronics.

[30]  Zhengyou He,et al.  Travelling wave time-frequency characteristic-based fault location method for transmission lines , 2012 .

[31]  Alan J. Watson,et al.  Robustness Analysis and Experimental Validation of a Fault Detection and Isolation Method for the Modular Multilevel Converter , 2016, IEEE Transactions on Power Electronics.

[32]  Mohammad Reza Zolghadri,et al.  A new fault detection method for modular multilevel converter semiconductor power switches , 2015, IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society.