Soft X-ray transmission of optical blocking filters for the X-ray CCD cameras onboard Astro-E 2

We measured soft X-ray transmission of Optical Blocking Filters for Charge Coupled Device cameras, which will be launched as focal plane detectors of X-ray telescopes onboard the Japanese fifth X-ray astronomical satellite, Astro-E 2. The filters were made from polyimide coated with Al. The X-ray absorption fine structures at the K edges of C, N, O and Al were measured. The depth of the absorption edge of O was deep, compared to the other elements of polyimide. This is the evidence of the oxidation of Al.

[1]  et al,et al.  The European Photon Imaging Camera on XMM-Newton: The MOS cameras : The MOS cameras , 2000, astro-ph/0011498.

[2]  Kazuo Sano,et al.  Fabrication of a varied-line-spacing plane grating with aspheric wavefront holographic recording for a new grazing incidence monochromator at the Photon Factory , 1997, Optics & Photonics.

[3]  T. Ohta,et al.  A soft X-ray (80-1500 eV) grazing-incidence monochromator with varied-line-spacing plane gratings at PF-BL-11A. , 1998, Journal of synchrotron radiation.

[4]  Emi Miyata,et al.  Quantum efficiency of the CCD camera (XIS) for the ASTRO-E mission , 1999 .

[5]  Emi Miyata,et al.  Measurement of the response characteristics around K absorption edges of dead-layer materials of a charge-coupled device , 2001 .

[6]  Michael J. Pivovaroff,et al.  Absolute calibration of ACIS x-ray CCDs using calculable undispersed synchrotron radiation , 2000, Astronomical Telescopes and Instrumentation.

[7]  Emi Miyata,et al.  Soft x-ray response of the prototype CCD camera (XIS) for Astro-E , 1998, Optics & Photonics.

[8]  G. Ricker,et al.  Soft X-ray response of a CCD with a grating spectrometer , 1999 .

[9]  T. Ohta,et al.  Design of a Holographically Recorded Plane Grating with a Varied Line Spacing for a Soft X-ray Grazing-Incidence Monochromator. , 1996, Journal of synchrotron radiation.

[10]  Elmar Pfeffermann,et al.  The European Photon Imaging Camera on XMM-Newton: The pn-CCD camera , 2001 .

[11]  Gregory Y. Prigozhin,et al.  Soft-X-ray CCD imagers for AXAF , 1997 .

[12]  Emi Miyata,et al.  Properties of the optical blocking filter of the XIS for the ASTRO-E mission , 2000 .

[13]  Marcos Bavdaz,et al.  X-ray and optical performance of the flight filters for the JET-X telescope , 1997, Optics & Photonics.

[14]  B. L. Henke,et al.  X-Ray Interactions: Photoabsorption, Scattering, Transmission, and Reflection at E = 50-30,000 eV, Z = 1-92 , 1993 .

[15]  G. Ricker,et al.  Reports of soft X-ray response of the engineering model of the CCD camera (XIS) for the ASTRO-E mission , 2000 .

[16]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.